ElecDemo WCS1800

Contents

WCS1800 Hall Current Sensor Module

DC AC Detection Module 30A Serial Output Overcurrent Protection

Model: WCS1800 | Brand: ElecDemo

1. Introduction

The ElecDemo WCS1800 Hall Current Sensor Module is designed for detecting both DC and AC currents up to 30A. It provides an analog voltage output and features a serial port for convenient data reading and threshold control. This module is equipped with overcurrent protection capabilities, making it suitable for a variety of applications including motor overcurrent detection, stall protection, and short circuit protection in industrial and educational settings.

Key Features:

  • Analog voltage output (0-5V).
  • Serial port output for direct connection to a computer via a USB to TTL module, enabling easy data acquisition.
  • On-board potentiometer for adjustable threshold settings.
  • Convenient threshold and relay control via serial port commands.
  • Integrated mounting holes for straightforward installation.

Applications:

  • AC current equipment monitoring (e.g., motor overcurrent detection, stall protection, short circuit protection).
  • Overcurrent protection systems.
  • Demonstration and teaching experiments.
  • Secondary development projects, compatible with inductive, capacitive, and resistive loads.

2. Specifications

Parameter Value
Main Chips Operational Amplifier, Transformer, Single Chip Microcomputer
Operating Voltage 7V~12V (Serial Port Provision)
Work Mode Serial port (read values directly via serial assistant)
Detection Current Range AC/DC 0-30A
Error ±0.2A
Type Other PLC Peripheral Modules
Origin Mainland China
Dimensions (approx.) 50mm x 33mm (module board), 42mm x 58mm (overall with relay), 40mm (distance between mounting holes)

3. Package Contents

  • WCS1800 Hall Current Sensor Module (x1)
  • PDF schematic (available upon request from customer service)

4. Setup

4.1 Module Overview and Pinout

Familiarize yourself with the module's components and pin assignments before connecting. The module includes a 5V relay, a current transformer, a potentiometer for threshold adjustment, and various pins for power, serial communication, and analog output.

Detailed diagram of WCS1800 Hall Current Sensor Module components and pinout
Figure 4.1: Detailed diagram of the WCS1800 module, showing components and pin labels.

Key Pin Assignments:

  • GND: Ground connection.
  • OUT: Analog voltage output (0-5V).
  • RX: Serial data receive.
  • TX: Serial data transmit.
  • 5V: Power supply input (7V-12V operating voltage, often supplied via serial port).

The module also features connections for the integrated relay: 'Always open', 'Public side', and 'Normally closed end'. The current transformer allows for current sensing by passing the wire through its perforation.

4.2 Connecting to a Computer

To communicate with the module and read values, connect the module's serial pins (RX, TX, GND, 5V) to a USB to TTL module, and then connect the USB to TTL module to your computer. Ensure the correct drivers for the USB to TTL module are installed on your computer.

WCS1800 module connected to a USB to TTL module and a laptop
Figure 4.2: WCS1800 module connected to a USB to TTL module for serial communication with a computer.

5. Operation

The module is operated using serial commands through a serial assistant software on your computer. Ensure your serial assistant is configured with the correct COM port, baud rate (typically 9600), data bits (8), parity (None), and stop bits (1).

5.1 Communication Test

To verify communication with the module:

  1. Open your serial assistant software.
  2. Send the command: AT
  3. The module should respond with: OK
Serial assistant showing AT command and OK response
Figure 5.1: Communication test using serial assistant.

5.2 Reading Current Value

To read the current value detected by the sensor:

  1. Send the command: AT+C
  2. The module will return the current value, for example: +C=0.99
Serial assistant showing AT+C command and current value response
Figure 5.2: Reading current value via serial command.

5.3 Measuring AC Current

For AC current measurement, pass the current-carrying wire through the perforation of the current transformer. The number of turns can affect the measurement sensitivity. For example, coiling the wire 9 times through the transformer will multiply the detected current by 9.

AC current measurement setup with multimeter and serial output
Figure 5.3: Example of AC current measurement. A 1A AC current coiled 9 times results in a detected 9A.
AC current measurement with 3A input and 9 turns
Figure 5.4: Example of AC current measurement. A 3A AC current coiled 9 times results in a detected 27A.

5.4 Measuring DC Current

For DC current measurement, pass the current-carrying wire through the perforation of the current transformer, ensuring the correct direction for the DC coil. Similar to AC, the number of turns affects sensitivity.

DC current measurement setup with multimeter and serial output
Figure 5.5: Example of DC current measurement. A 2A DC current coiled 9 times results in a detected 18A.
DC current measurement with 1A input and 9 turns
Figure 5.6: Example of DC current measurement. A 1A DC current coiled 9 times results in a detected 9A.

6. Calibration Settings

The module supports current correction to improve accuracy. Follow these steps using your serial assistant:

  1. Enter Correction Mode: Send AT+ADJ=1N
  2. Set Number of Corrections: Send AT+ADJ=10 (This sets the maximum number of corrections to 10 times). The module should return ADJ_LEN=10.
  3. Ground Correction (0A): Ensure no current is flowing through the sensor. Send AT+ADJ=0. The module should return ADJ_TIME=1.
  4. Adjust for 1A: Apply a known 1A current through the sensor. Send AT+ADJ=1. The module should return ADJ_TIME=2.
  5. Repeat step 4 for other known current values as needed, up to 10 times.
  6. Exit Calibration Mode: After completing your adjustments, send AT+ADJ=10. The module should return ADJ_TIME=10, indicating calibration is complete.
Serial assistant showing AT+ADJ=1N command to enter correction mode
Figure 6.1: Entering current correction mode.
Serial assistant showing AT+ADJ=10 command to set number of corrections
Figure 6.2: Setting the number of corrections.
Serial assistant showing AT+ADJ=0 command for ground correction
Figure 6.3: Performing ground correction.
Serial assistant showing AT+ADJ=1 command for 1A adjustment
Figure 6.4: Adjusting for a 1A current.

Note: When switching between DC and AC detection modes, it is recommended to recalibrate the module for optimal accuracy.

7. Alarm System

The module supports setting high and low current alarm thresholds, which can trigger the on-board relay and warning LED.

  1. Set High Alarm Threshold: Send AT+ERRUP=X.X (Replace X.X with your desired high current threshold in Amperes, e.g., AT+ERRUP=2.5 for 2.5A).
  2. Set Low Alarm Threshold: Send AT+ERRDOWN=X.X (Replace X.X with your desired low current threshold in Amperes, e.g., AT+ERRDOWN=0.5 for 0.5A).
  3. Activate Relay/LED for Thresholds: Send AT+P=1. This command configures the relay and LED warning lights to activate when the detected current falls outside the set high and low thresholds.
Serial assistant showing AT+ERRDOWN command to set low alarm threshold
Figure 7.1: Setting the low alarm threshold.
Serial assistant showing AT+P=1 command to activate relay and LED warning lights
Figure 7.2: Activating relay and LED warning lights based on thresholds.

8. User Tips

No specific user tips were available from the provided data. However, general best practices for using electronic modules include:

  • Always double-check wiring before applying power to prevent damage.
  • Ensure your power supply voltage is within the specified 7V-12V range.
  • When measuring current, ensure the wire is properly passed through the current transformer's perforation.
  • For critical applications, perform regular calibration to maintain accuracy.

9. Maintenance

The WCS1800 module is designed for low maintenance. To ensure its longevity and reliable operation:

  • Keep the module clean and free from dust and debris.
  • Avoid exposing the module to extreme temperatures, humidity, or corrosive environments.
  • Handle the module with care to prevent physical damage to components or solder joints.
  • Periodically inspect connections for any signs of wear or corrosion.

10. Troubleshooting

  • No communication with module:
    • Verify power supply to the module (7V-12V).
    • Check serial wiring (RX to TX, TX to RX, GND to GND).
    • Ensure the correct COM port and baud rate are selected in your serial assistant.
    • Confirm USB to TTL module drivers are installed correctly.
  • Inaccurate current readings:
    • Perform calibration as described in Section 6.
    • Ensure the wire is properly centered and passed through the current transformer.
    • Check for external electromagnetic interference.
    • Verify the number of turns of the wire through the transformer.
  • Relay not activating/LED not lighting up:
    • Ensure alarm thresholds are set correctly (Section 7).
    • Verify the AT+P=1 command has been sent to activate the relay/LED based on thresholds.
    • Check the relay's power supply if it's external.

11. Warranty and Support

For technical support, detailed schematics (PDF), or any inquiries regarding the WCS1800 Hall Current Sensor Module, please contact the ElecDemo Official Store customer service. They can provide further assistance and documentation after purchase.