1. Introduction
This manual provides comprehensive instructions for the Hantek TO1112D series multi-functional full touch screen oscilloscope. It covers safety information, product features, setup, operation, maintenance, and troubleshooting to ensure safe and efficient use of the device.
The Hantek TO1000 series is a new generation of handheld flat oscilloscopes featuring a 7-inch industrial specification TFT-LCD 800*480 resolution capacitive touch screen. It offers a multi-point touch operation for an intuitive user experience. The TO1112D model integrates an oscilloscope, signal source, and multimeter functions. It is designed to be thin, lightweight, and portable, with a unique hanging design for hands-free operation, anti-falling, and anti-seismic durability. It includes a built-in large capacity battery for long endurance and supports fast charging.
Video: Overview of the Hantek TO1000 Series Oscilloscope highlighting its features like portability, multi-functionality, and durability.
2. Safety Information
Read all safety precautions carefully to prevent injury and damage to the product or any connected equipment. Use this product only in accordance with the regulations.
2.1 General Safety Issues
- Only professionally authorized personnel should perform repairs.
- Use the correct power cable, approved for the country of use.
- Connect the probe to the oscilloscope before connecting it to the circuit under test. Disconnect from the circuit before disconnecting from the oscilloscope.
- Ensure the product is properly grounded via the power cable's grounding conductor to prevent electric shocks.
- Connect the probe correctly: The probe's ground wire is at ground potential. Do not connect it to high voltage.
- Observe all terminal rating values to avoid fire or excessive current. Consult the product manual for detailed rating values.
- Do not operate with the cover open.
- Avoid touching exposed connectors and components after power is switched on.
- If the product is suspected to be faulty or damaged, have it checked by qualified maintenance personnel.
2.2 Environmental Considerations
- Maintain proper ventilation.
- Do not operate in humid, inflammable, or explosive environments.
- Keep the product surface clean and dry.
- Warning: Equipment meeting Class A requirements may not provide adequate protection for broadcast services in residential environments.
- Warning: To avoid short circuits or electric shock, do not operate the device in a damp environment.
- Warning: Before powering on after cleaning, ensure the device is completely dry to prevent electrical short circuits or personal injury due to moisture.
2.3 Measurement Category
This instrument is designed for Class I measurements, meaning it is used on circuits not directly connected to the main power supply. It is only allowed to be used in the specified measurement class.
2.4 Installation (Overvoltage) Class
This product is powered by a mains supply conforming to Installation (overvoltage) Class II.
- Warning: Ensure no overvoltage (e.g., from lightning) reaches the product to prevent electric shock.
2.5 Pollution Level
- Pollution degree 1: No pollution, or only dry non-conductive pollution (e.g., clean room).
- Pollution degree 2: Generally dry non-conductive pollution, with transient conduction possible due to condensation (e.g., general indoor environment).
- Pollution degree 3: Conductive pollution, or dry non-conductive pollution becoming conductive by condensation (e.g., outdoor environment with canopy).
- Pollution degree 4: Permanent conductive pollution through conductive dust, rain, or snow (e.g., outdoor places).
The device is rated for 2 class pollution.
3. Product Features
- Display: 7-inch industrial TFT-LCD, 800*480 multi-point full touch capacitive screen.
- Channels: 2-channel oscilloscope + 1 AFG channel (TO1112D).
- Bandwidth: 110MHz.
- Sampling Rate: 250MSa/s (2-channel), 1GSa/s (4-channel models).
- Storage Depth: 8Mpts (single channel), 4Mpts (double channel).
- Vertical Sensitivity: 10mV/div ~ 10V/div.
- Functions: Oscilloscope, Multimeter, Signal Source.
- Trigger Functions: Edge, pulse width, video, slope, timeout.
- Measurements: Up to 42 automatic waveform parameters.
- Mathematical Operations: Addition, subtraction, multiplication, division, FFT.
- Connectivity: Standard USB port.
- Power: Built-in 5000mAh removable lithium battery (2-channel models).
- Charging: Standard 9V2A/5V3A/12V1.5A charger, USB interface input, Type-C fast charging.
- Design: Unique hanging design with supporting foot for hands-free operation, anti-shock corners for durability.
- Portability: Super thin, lightweight (less than 1Kg), easy to carry.

Image: Overview of the Hantek TO1000 series highlighting its multi-functionality including oscilloscope, signal generator, multimeter, kickstand, battery, and fast charging.
4. Setup
4.1 General Examination
Upon receiving the oscilloscope, perform the following checks:
- Shipping Package: Inspect for any damage caused during transportation. If the packaging or foam pads are severely damaged, retain them until the device passes electrical and mechanical testing.
- Accessories: Refer to the accessories list in Appendix A. If any accessory is missing or damaged, contact your dealer.
- Machine: If the instrument is damaged, not working properly, or fails performance tests, contact your dealer.
4.2 Appearance and Dimensions

Image: Front view of the Hantek TO1112D oscilloscope displaying a waveform.

Image: Side view of the Hantek TO1112D showing the USB and Type-C ports.

Image: Rear view of the Hantek TO1112D with its integrated kickstand.
4.3 Preparation Before Use
4.3.1 Connect the Power Supply
The oscilloscope is equipped with 4 x 3.7V 2600 mAh batteries. Ensure batteries have sufficient charge before use.
- Press the power button to turn the instrument on/off. A buzzer will sound upon startup.
- A blank battery icon on the screen indicates low battery.
- If the battery level drops below 3.5V, the oscilloscope will prompt for shutdown. Charge the device promptly to avoid automatic shutdown.
- If the power button is pressed and the buzzer rings continuously without the oscilloscope responding, the battery may be exhausted.
Charging Methods:
- Connect the oscilloscope to a power socket using the provided USB data cable and power adapter.
- When charging while the machine is off, the power button indicator light will be on.
- When charging while the machine is on, the battery icon on the screen will change (slow charge or quick charge indication).
- Charging stops automatically when the battery is full.
4.3.2 Boot Check
Press the power button located at the bottom of the right panel to start the instrument.
Shutdown:
- Tap the shutdown icon on the main interface to shut down directly.
- In the boot state, press the power button to shut down directly.
4.3.3 Set the System Language
The oscilloscope supports Chinese and English. From the main interface, navigate to [HOME] > [Settings] > [Language] to select your preferred language. The default language is English.
4.3.4 Functional Check
Click [OSC] or tap [OSC] in the main interface to enter the oscilloscope interface. To restore factory default configurations, click Utility > Default in the lower left corner of the screen.
4.3.5 Probe Compensation
Safety: When using the probe, keep fingers behind the safety ring. Do not touch the metal part of the probe when connected to high voltage. Always connect the probe to the oscilloscope and ground the ground end before any measurement.
Manual Probe Compensation: When connecting a probe to an input channel for the first time, perform compensation to match the probe to the input channel. Uncompensated or biased probes can lead to measurement errors.
- Connect one end of the probe to the CH1 channel and the other end to the AFG channel.
- Enter the oscilloscope interface, click Utility > Probe calibrate, and set the probe switch to 10X as prompted.
- Check the displayed waveform. Adjust the variable capacitance on the probe with a non-metallic screwdriver until the waveform is "compensated correctly".

Image: Hand interacting with the touch screen interface of the Hantek TO1112D.
5. Operating Instructions
5.1 Touch Screen Gestures
The instrument is primarily operated via its built-in capacitive touch screen, supporting multi-touch gestures for a flexible and convenient user experience.
- Touching: Tap menus, functions, virtual keyboards, or numeric keypads to operate or set parameters.
- Kneading: Move two fingers together or apart to zoom in/out of the waveform. Vertical kneading adjusts vertical gear, horizontal kneading adjusts horizontal gear.
- Dragging: Hold down a target and drag it to a desired position. This can change waveform displacement/offset, cursor position, or trigger position.
5.2 Horizontal System
The horizontal system controls the time base and horizontal displacement of the waveform.
- Adjust Horizontal Displacement: Drag the horizontal trigger position icon on the screen.
- Adjust Horizontal Time Base (Time/Grid): Tap the +/- buttons at the bottom of the screen or use kneading gestures.
- Pan or Zoom: After stopping data collection, you can pan and zoom the last collected data.
5.3 Vertical System
The TO1112D provides two input channels (CH1-CH2), each with an independent vertical control system.
- Open/Close Analog Channel: Tap the channel icon to toggle between open, open vertical menu, or close. Yellow indicates open, gray indicates closed.
- Adjust Vertical Sensitivity: Tap the vertical sensitivity labels or use kneading gestures to adjust the waveform amplitude.
- Adjust Vertical Offset: Drag the waveform or use the arrow icons in the Vertical channel menu.
- Channel Coupling: Set to DC, AC, or Grounded to filter unwanted signals.
- 20M Bandwidth Limit: Enable to reduce noise in the display waveform.
- Waveform Inversion: Inverts the voltage value of the waveform.
- Probe: Manually set the probe attenuation ratio (1X to 10000X) for accurate measurements.
- Amplitude Unit: Select between voltage or current units.
5.4 Mathematical Operations
The oscilloscope supports various mathematical operations on analog channel waveforms.
- Algebraic Operations: Perform addition, subtraction, multiplication, and division between data sources (CH1-CH2).
- FFT Operation: Convert time domain (YT) signals to frequency domain. Select data source, vertical units (VRms or dB), and window functions (Hanning, Hamming, Blackman, Bartlett, Flat top, Rectangular).
- Cursor Measurement: Use vertical or horizontal cursors to measure frequency, amplitude, and differences.
5.5 Trigger Oscilloscope
Triggering sets conditions for capturing and displaying waveforms.
- Trigger Level: Adjust the signal voltage corresponding to the trigger point by dragging the trigger flag.
- Trigger Data Source: Select CH1 or CH2 as the trigger source.
- Trigger Mode: Choose Normal, Automatic, or Single trigger mode.
- Trigger Hold-off: Set the time the oscilloscope waits before re-triggering to stabilize complex waveforms.
- Trigger Type:
- Edge-triggered: Triggers on rising, falling, or double edges at a specified voltage level.
- Pulse Width Trigger: Triggers on positive or negative pulses of a specified width.
- Video Trigger: Captures complex waveforms from standard analog or HD video signals (NTSC, PAL, HDTV).
- Slope Trigger: Triggers based on positive or negative slope time between two voltage levels.
- Timeout Trigger: Triggers when the time interval between edges passing the trigger level exceeds a set timeout.
5.6 Measurements
The oscilloscope offers various measurement methods:
- Grid Scale Measurement: Quickly estimate frequency and voltage amplitude using the grid divisions and scale coefficients.
- Automatic Measurements: Perform up to 42 automatic measurements including time parameters (Period, Frequency, Rise/Fall Time, Pulse Width, Duty Cycle) and voltage parameters (Vmax, Vmin, PK-PK, Vtop, Vbase, Vampl, Vmid, Average, RMS).
5.7 Acquisition
Acquisition settings determine how the oscilloscope collects and processes data.
- Acquisition Mode:
- Normal: Samples signals at equal intervals.
- Average: Averages multiple waveforms to reduce random noise.
- Peak Detection: Captures maximum and minimum values at each sampling interval to display narrow pulses.
- High Resolution: Uses hypersampling to reduce random noise and produce smoother waveforms.
- Display Mode: Choose YT (voltage vs. time), XY (voltage vs. voltage for phase analysis), or Scroll (waveform refresh from right to left).
- Storage Depth: Set the number of waveform points the oscilloscope can store (4K, 20K, 200K, 2M, 4M, 8M).
- Interpolation Methods: Sine wave, step, or linear interpolation to connect sample points and reconstruct waveforms.
5.8 Multimeter Function
The TO1112D includes a high-precision multimeter with data recording, storage, trend chart, and statistical analysis functions.
- Access: Click the [Multimeter] icon on the main interface or tap the virtual key [DMM].
- Measurements: DC voltage (V-, mV-), AC voltage (V~), Resistance (Ω), On/Off, DC current (A-, mA-), AC current (A~, mA~), Diode, Capacitor.
- Display: Real-time display of measured values, updated trend charts, and numerical tables of recorded values.
- Save: Save measured values to a USB disk.

Image: Side view of the Hantek TO1112D showing the multimeter input ports (V/Ω/C, COM, mA, A).
5.9 Signal Source Function
The TO1112D features a signal generator with a variety of arbitrary waveforms and a highest output frequency of 25MHz.
- Access: Click [AFG] to enter the signal source interface.
- Waveform Types: Edit any waveform or select sine, square, triangle, noise, DC, and arbitrary waveforms.
- Parameters: Set frequency, period, amplitude, high/low level, offset, phase, duty cycle, symmetry, and output load impedance (default 50Ω).
- Waveform Modulation: Supports Amplitude Modulation (AM) and Frequency Modulation (FM).
- Burst: Set the number of pulses for burst output.
- Arbitrary Waveform Editing: Use the "WaveEditor_Setup_Tablet1000.exe" software on a computer to create and download arbitrary waveforms via USB.
6. Maintenance and Cleaning
6.1 Maintenance
- Do not expose the LCD to direct sunlight for prolonged periods when storing or placing the oscilloscope.
6.2 Cleaning
Regularly inspect and clean the oscilloscope and probes:
- Use a lint-free cloth to remove dust from the outer surface. Be careful not to scratch the display filter material.
- Clean the oscilloscope with a soft cloth dampened with water. For a more thorough cleaning, use a 75% isopropyl alcohol aqueous solution.
Note: Do not use corrosive reagents or chemical cleaning agents to avoid damaging the surface of the oscilloscope or probe.
7. Troubleshooting
7.1 No Display After Pressing Power Button
- Check if the battery is charged.
- Check if the power button is pressed firmly.
- If the issue persists after checking, contact Hantek support.
7.2 No Waveform Displayed on Input Signal Screen
- Verify the probe is properly connected to the BNC connector of the input channel.
- Ensure the channel switch is enabled (CH1 or CH2).
- Confirm the input signal is properly connected to the probe.
- Verify the measured circuit has signal output.
- If it's a high-amplitude DC signal, adjust the amplitude gear to a higher value.
- Press the automatic measurement button to detect the signal.
- If no waveform is displayed, contact Hantek support.
7.3 Serious Distortion of Input Signal Waveform
- Check if the oscilloscope probe is properly connected to the BNC connector.
- Check if the probe is properly connected to the object under test.
- Ensure the probe is well calibrated. If not, perform probe compensation as described in Section 4.3.5.
7.4 Waveform Constantly Scrolling and Cannot Be Triggered
- Check if the trigger source is consistent with the signal input channel.
- Check if the trigger level is properly adjusted.
- Ensure the trigger mode is appropriate for the input signal. The default is edge trigger.
8. Specifications
| Attribute | Value |
|---|---|
| Brand Name | Hantek |
| Model Number | TO1112/TO1112C/TO1112D |
| HANTEK Model | TO1112D |
| DIY Supplies | Electrical |
| Certification | CE |
| Origin | Mainland China |
| Digital Channels | 2 |
| Band Width | 110MHz |
| Real Time Sampling Rate | 1GSa/S |
| Max Waveform Capture Rate | 30,000wfm/s |
| Record Length | 8M |
| Display Resolution | 800*480 Pixels |
| Display Size | 7 Inches & Above |
| Battery Included | No (but has built-in removable lithium battery) |
| IS Battery Demountable | No (but product description states 'removable lithium battery') |
| High-concerned chemical | None |
8.1 Model Comparison (TO1000 Series)
| Model | Oscilloscope Channel | Bandwidth | Sampling Rate | Storage Depth | Signal Source | Multimeter |
|---|---|---|---|---|---|---|
| TO1112 | 2CH | 110MHz | 250MSa/S | 8M | - | - |
| TO1112C | 2CH | 110MHz | 250MSa/S | 8M | - | √ |
| TO1112D | 2CH | 110MHz | 250MSa/S | 8M | 25MHz | √ |

Image: Table comparing Hantek TO1000 series models (TO1112, TO1112C, TO1112D) based on oscilloscope channels, bandwidth, sampling rate, storage depth, signal source, and multimeter functionality.
9. User Tips
- Automotive Use: While the TO1112D is a versatile oscilloscope, specific automotive diagnostic features may vary. Consult the manual's detailed measurement and trigger sections to determine suitability for particular automotive tests.
- Language Updates: The device supports English and Chinese. For other languages, check the Hantek website for potential firmware updates or language packs. The manual can be downloaded from www.hantek.com.
10. Warranty and Support
10.1 Warranty Summary
Qingdao Hantek Electronics Co., LTD. (Hantek) warrants that the host and accessories are free from material and process defects during the specified warranty period. During this period, Hantek will repair or replace defective products free of charge. For detailed warranty regulations, repair services, or full warranty instructions, please refer to the Hantek official website or contact a Hantek repair center or local office.
Hantek disclaims all other warranties, express or implied, including merchantability and fitness for a special purpose, beyond what is stated in this summary or any applicable warranty card. Hantek is not liable for indirect, special, or consequential damages.