1. Introduction
The KAIWEETS KTI-200 is a high-performance thermal imaging camera designed for a wide range of applications, including home leak detection, vehicle maintenance, electrical inspection, and industrial inspection. It features a 240x240 infrared resolution, a 2.4-inch TFT LCD, and a broad temperature measurement range from -4°F to 1022°F (-20°C to 550°C). This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your KTI-200 thermal imager.
2. Safety Information
Please read and understand all safety warnings and operating instructions before using this product. Failure to do so may result in injury or damage to the device.
- Do not point the laser directly at eyes or reflective surfaces.
- Do not expose the device to extreme temperatures outside its operating range (-10℃ to +50℃) or storage range (-40℃ to +70℃).
- Avoid dropping the device from heights greater than 1.5m.
- Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
- Ensure the device is charged using the provided USB-C cable and a compatible 5V/2A charger.
3. Package Contents
Verify that all items are present upon unpacking:
- 1 x KAIWEETS KTI-200 Thermal Imager
- 1 x USB-C Cable
- 1 x User Manual
4. Setup
4.1 Charging the Battery
- Connect the provided USB-C cable to the camera's Type-C USB port.
- Connect the other end of the USB-C cable to a 5V/2A power adapter (not included).
- The battery indicator on the display will show charging status. A full charge takes approximately 3 hours at 25℃.
The KTI-200 uses a rechargeable lithium battery (3.7V/2500mAh) and offers over 7 hours of continuous operation at 25℃ on a full charge.
4.2 Powering On/Off
- Power On: Press and hold the Power button (usually marked with a circle and vertical line) for approximately 3 seconds until the display illuminates.
- Power Off: Press and hold the Power button again until the device shuts down.
The device has an automatic power-off feature, which can be configured (Disable, 10 Min, 20 Min, 30 Min, 40 Min, 50 Min, 60 Min). The default setting is disabled.
4.3 Tripod Mounting
The KTI-200 is equipped with a standard UNC-20 tripod mount for stable, hands-free operation during extended inspections or precise positioning.
5. Operating Instructions
5.1 Basic Operation and Navigation
The device is operated using the following buttons:
- Power Button: Powers the device on/off.
- Up Button: Navigates menus upwards or increases values.
- Down Button: Navigates menus downwards or decreases values.
- Return Button: Returns to the previous menu or cancels an action.
- Trigger Button: (Red button on the handle) Activates the laser pointer and captures images.
5.2 Thermal Imaging and Temperature Measurement
The KTI-200 provides a 240x240 pixel thermal image resolution with a 25Hz frame rate for smooth, real-time thermal visualization. It measures temperatures from -4°F to 1022°F (-20°C to 550°C) with an accuracy of ±2℃ or ±2% (whichever is greater).
5.3 Laser Pointer
Press the Trigger button to activate the built-in laser pointer for precise targeting. The laser is effective for distances between 0.98ft and 9.84ft (0.3m and 3m).
5.4 Emissivity Adjustment
Emissivity (ε) is a measure of an object's ability to emit infrared energy. For accurate temperature readings, adjust the emissivity setting (0.01-1.00) to match the material being measured. Refer to the table below for common material emissivity values.
5.5 Color Palettes
The KTI-200 offers 15 color palettes to optimize thermal image visualization and help identify problems more easily. These include:
- White Hot
- Black Hot
- Fusion 1
- Rainbow
- Fusion 2
- Iron Red 1
- Iron Red 2
- Deep Brown
- Color 1
- Color 2
- Ice Fire
- Rain
- Green Hot
- Red Hot
- Deep Blue
5.6 Temperature Tracking and Alarms
The device features automatic temperature tracking, displaying the center point temperature, as well as tracking the highest (Hot Spot) and lowest (Cold Spot) temperatures within the field of view. A screen font color alarm indicates high/low temperature thresholds.
5.7 Image Storage and Transfer
The KTI-200 has a built-in memory card capable of storing up to 30,000 thermal images in BMP format. Images can be transferred to a computer effortlessly via the USB-C connection for further analysis and reporting.
5.8 Applications
The KTI-200 is versatile and can be used for:
- Home Leak Detection
- Vehicle Maintenance
- Electrical Inspection
- Industrial Inspection
6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the camera body. For the lens, use a lens cleaning cloth and solution designed for optics. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place within the specified storage temperature range of -40℃ to +70℃ and working humidity of ≤85%RH (Non-condensing).
- Battery Care: For long-term storage, ensure the battery is partially charged (around 50%) to prolong its lifespan. Recharge periodically if stored for extended periods.
7. Troubleshooting
- Device does not power on: Ensure the battery is sufficiently charged. Connect to a power source and try again.
- Inaccurate temperature readings: Check and adjust the emissivity setting for the material being measured. Ensure the measurement distance is within the optimal range (0.3m-3m).
- Display issues: If the screen is frozen or unresponsive, try restarting the device by holding the power button.
- Image transfer issues: Ensure the USB-C cable is securely connected to both the camera and the computer. Check if the computer recognizes the device.
8. Specifications
| Category | Parameter | Value |
|---|---|---|
| General | Brand | KAIWEETS |
| Type | Thermal Imager | |
| Model | KTI-200 | |
| Color | Black | |
| Thermal & Optical | Sensor type | Vanadium oxide (VOx) microcalorimeter |
| Response band | 8–14μm | |
| Thermal image resolution | 240x240 Pixels | |
| Noise equivalent temperature difference (NETD) | ≤60 mK (@25℃, F#1.0) | |
| Field of view (FOV) | 50.0°(H)×50°(V)/72.1°(D) | |
| Instantaneous field of view (IFOV) | 8.89 mrad | |
| Frame rate | 25Hz | |
| Focal length of imaging lens | 1.35mm | |
| Temperature measuring focal length | 0.3m–3m Adjustable | |
| Temperature range | –20℃ to +550℃ (-4°F to 1022°F) | |
| Accuracy of temperature measurement | ±2℃ or ±2% of the reading (take the larger value) | |
| Unit of temperature measurement | Celsius, Fahrenheit, Kelvin | |
| Temperature resolution | 0.1℃ | |
| Emissivity | 0.01-1.00 Adjustable | |
| Temperature measurement shows | Center point, high and low temperature tracking | |
| Swatches (Color Palettes) | White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Deep Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Deep Blue (15 total) | |
| Display screen | 2.4 inches TFT LCD | |
| Display resolution | 320x240 | |
| Buttons | Power, Up, Down, Return, Trigger | |
| Laser pointer | Yes | |
| Temperature alarm | Screen font color alarm | |
| Image storage | Built-in memory card | |
| Number of image files | 30000 | |
| Image format | BMP | |
| Environmental & Power | Shock/vibration | GB/T 2423.5-2019; GB/T 2423.10-2008 |
| Electromagnetic compatibility (EMC) | GB/T 17799.2; GB17799.3-2012 | |
| Protection level | IP54 | |
| Installation mode | Tripod mount UNC-20 | |
| Focus mode | Auto focusing | |
| Hardware interface | Type-C USB | |
| Battery type | Rechargeable lithium battery (3.7V/2500mAh) | |
| Working hours of the battery | >7h@25℃ | |
| Charging time | <3h@25℃ | |
| Charging voltage/current | 5V/2A | |
| Operational | Boot speed | 3 seconds |
| Automatic power off | Disable (default) / 10 Min, 20 Min, 30 Min, 40 Min, 50 Min, 60 Min | |
| Operating temperature | –10℃ to +50℃ | |
| Storage temperature | –40℃ to +70℃ | |
| Working humidity | ≤85%RH (Non-condensing) | |
| Physical | Drop resistance | 1.5m |
| Product Weight | 0.28kg | |
| Product Size (L x W x H) | 19.3 x 5.9 x 7.7cm | |
| Package Weight | 0.485kg |
9. User Tips
- Emissivity Matters: Always try to set the correct emissivity for the material you are inspecting. Incorrect emissivity is a common cause of inaccurate temperature readings.
- Optimal Distance: For the most accurate measurements, operate the camera within its specified temperature measuring focal length of 0.3m to 3m.
- Palette Choice: Experiment with different color palettes to find the one that best highlights the temperature differences relevant to your inspection. Some palettes are better for subtle changes, while others emphasize extreme temperatures.
- Documentation: Utilize the image storage feature to document your findings. Transfer images regularly to your computer for detailed analysis and record-keeping.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.