KAIWEETS KTI-200

Contents

KAIWEETS KTI-200 Thermal Imaging Camera

User Manual

1. Introduction

The KAIWEETS KTI-200 is a high-performance thermal imaging camera designed for a wide range of applications, including home leak detection, vehicle maintenance, electrical inspection, and industrial inspection. It features a 240x240 infrared resolution, a 2.4-inch TFT LCD, and a broad temperature measurement range from -4°F to 1022°F (-20°C to 550°C). This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your KTI-200 thermal imager.

KAIWEETS KTI-200 Thermal Imaging Camera with USB-C cable and carrying case
Figure 1: KAIWEETS KTI-200 Thermal Imaging Camera and included accessories.

2. Safety Information

Please read and understand all safety warnings and operating instructions before using this product. Failure to do so may result in injury or damage to the device.

  • Do not point the laser directly at eyes or reflective surfaces.
  • Do not expose the device to extreme temperatures outside its operating range (-10℃ to +50℃) or storage range (-40℃ to +70℃).
  • Avoid dropping the device from heights greater than 1.5m.
  • Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
  • Ensure the device is charged using the provided USB-C cable and a compatible 5V/2A charger.

3. Package Contents

Verify that all items are present upon unpacking:

  • 1 x KAIWEETS KTI-200 Thermal Imager
  • 1 x USB-C Cable
  • 1 x User Manual
Image showing the KAIWEETS KTI-200 thermal camera, USB-C cable, and user manual, with dimensions of the device.
Figure 2: Contents of the KTI-200 package and device dimensions.

4. Setup

4.1 Charging the Battery

  1. Connect the provided USB-C cable to the camera's Type-C USB port.
  2. Connect the other end of the USB-C cable to a 5V/2A power adapter (not included).
  3. The battery indicator on the display will show charging status. A full charge takes approximately 3 hours at 25℃.

The KTI-200 uses a rechargeable lithium battery (3.7V/2500mAh) and offers over 7 hours of continuous operation at 25℃ on a full charge.

4.2 Powering On/Off

  • Power On: Press and hold the Power button (usually marked with a circle and vertical line) for approximately 3 seconds until the display illuminates.
  • Power Off: Press and hold the Power button again until the device shuts down.

The device has an automatic power-off feature, which can be configured (Disable, 10 Min, 20 Min, 30 Min, 40 Min, 50 Min, 60 Min). The default setting is disabled.

4.3 Tripod Mounting

The KTI-200 is equipped with a standard UNC-20 tripod mount for stable, hands-free operation during extended inspections or precise positioning.

5. Operating Instructions

5.1 Basic Operation and Navigation

The device is operated using the following buttons:

  • Power Button: Powers the device on/off.
  • Up Button: Navigates menus upwards or increases values.
  • Down Button: Navigates menus downwards or decreases values.
  • Return Button: Returns to the previous menu or cancels an action.
  • Trigger Button: (Red button on the handle) Activates the laser pointer and captures images.
KAIWEETS KTI-200 showing 240x240 IR resolution, 2.4 inch LCD screen, 25Hz smooth refresh rate, and example thermal images.
Figure 3: Key features and display of the KTI-200.

5.2 Thermal Imaging and Temperature Measurement

The KTI-200 provides a 240x240 pixel thermal image resolution with a 25Hz frame rate for smooth, real-time thermal visualization. It measures temperatures from -4°F to 1022°F (-20°C to 550°C) with an accuracy of ±2℃ or ±2% (whichever is greater).

Image illustrating the wide temperature range of the KAIWEETS KTI-200 from -4°F to 1022°F.
Figure 4: The KTI-200's wide temperature measurement range.

5.3 Laser Pointer

Press the Trigger button to activate the built-in laser pointer for precise targeting. The laser is effective for distances between 0.98ft and 9.84ft (0.3m and 3m).

A person using the KAIWEETS KTI-200 with its laser pointer active, showing distance adjustment from 0.98ft to 9.84ft.
Figure 5: Using the laser pointer for fast detection and distance adjustment.

5.4 Emissivity Adjustment

Emissivity (ε) is a measure of an object's ability to emit infrared energy. For accurate temperature readings, adjust the emissivity setting (0.01-1.00) to match the material being measured. Refer to the table below for common material emissivity values.

Emissivity reference table for common materials, showing values for wood, water, brick, stainless steel, and more.
Figure 6: Emissivity reference for common materials.

5.5 Color Palettes

The KTI-200 offers 15 color palettes to optimize thermal image visualization and help identify problems more easily. These include:

  • White Hot
  • Black Hot
  • Fusion 1
  • Rainbow
  • Fusion 2
  • Iron Red 1
  • Iron Red 2
  • Deep Brown
  • Color 1
  • Color 2
  • Ice Fire
  • Rain
  • Green Hot
  • Red Hot
  • Deep Blue
Image showing the KAIWEETS KTI-200 display cycling through various color palettes.
Figure 7: Visual representation of the 15 available color palettes.

5.6 Temperature Tracking and Alarms

The device features automatic temperature tracking, displaying the center point temperature, as well as tracking the highest (Hot Spot) and lowest (Cold Spot) temperatures within the field of view. A screen font color alarm indicates high/low temperature thresholds.

KAIWEETS KTI-200 display showing Center Spot, Cold Spot, Hot Spot tracking, and a High/Low Temperature Alarm icon.
Figure 8: Auto temperature tracking features.

5.7 Image Storage and Transfer

The KTI-200 has a built-in memory card capable of storing up to 30,000 thermal images in BMP format. Images can be transferred to a computer effortlessly via the USB-C connection for further analysis and reporting.

KAIWEETS KTI-200 connected to a laptop via USB-C cable, illustrating image transfer and 30,000 image storage capacity.
Figure 9: Image storage and USB-C transfer capability.

5.8 Applications

The KTI-200 is versatile and can be used for:

  • Home Leak Detection
  • Vehicle Maintenance
  • Electrical Inspection
  • Industrial Inspection
Four images showing various applications of the thermal camera: electrical panels, floor heating, car engine, and drone circuit board.
Figure 10: Wide range of applications for the KTI-200.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the camera body. For the lens, use a lens cleaning cloth and solution designed for optics. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place within the specified storage temperature range of -40℃ to +70℃ and working humidity of ≤85%RH (Non-condensing).
  • Battery Care: For long-term storage, ensure the battery is partially charged (around 50%) to prolong its lifespan. Recharge periodically if stored for extended periods.

7. Troubleshooting

  • Device does not power on: Ensure the battery is sufficiently charged. Connect to a power source and try again.
  • Inaccurate temperature readings: Check and adjust the emissivity setting for the material being measured. Ensure the measurement distance is within the optimal range (0.3m-3m).
  • Display issues: If the screen is frozen or unresponsive, try restarting the device by holding the power button.
  • Image transfer issues: Ensure the USB-C cable is securely connected to both the camera and the computer. Check if the computer recognizes the device.

8. Specifications

Category Parameter Value
General Brand KAIWEETS
Type Thermal Imager
Model KTI-200
Color Black
Thermal & Optical Sensor type Vanadium oxide (VOx) microcalorimeter
Response band 8–14μm
Thermal image resolution 240x240 Pixels
Noise equivalent temperature difference (NETD) ≤60 mK (@25℃, F#1.0)
Field of view (FOV) 50.0°(H)×50°(V)/72.1°(D)
Instantaneous field of view (IFOV) 8.89 mrad
Frame rate 25Hz
Focal length of imaging lens 1.35mm
Temperature measuring focal length 0.3m–3m Adjustable
Temperature range –20℃ to +550℃ (-4°F to 1022°F)
Accuracy of temperature measurement ±2℃ or ±2% of the reading (take the larger value)
Unit of temperature measurement Celsius, Fahrenheit, Kelvin
Temperature resolution 0.1℃
Emissivity 0.01-1.00 Adjustable
Temperature measurement shows Center point, high and low temperature tracking
Swatches (Color Palettes) White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Deep Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Deep Blue (15 total)
Display screen 2.4 inches TFT LCD
Display resolution 320x240
Buttons Power, Up, Down, Return, Trigger
Laser pointer Yes
Temperature alarm Screen font color alarm
Image storage Built-in memory card
Number of image files 30000
Image format BMP
Environmental & Power Shock/vibration GB/T 2423.5-2019; GB/T 2423.10-2008
Electromagnetic compatibility (EMC) GB/T 17799.2; GB17799.3-2012
Protection level IP54
Installation mode Tripod mount UNC-20
Focus mode Auto focusing
Hardware interface Type-C USB
Battery type Rechargeable lithium battery (3.7V/2500mAh)
Working hours of the battery >7h@25℃
Charging time <3h@25℃
Charging voltage/current 5V/2A
Operational Boot speed 3 seconds
Automatic power off Disable (default) / 10 Min, 20 Min, 30 Min, 40 Min, 50 Min, 60 Min
Operating temperature –10℃ to +50℃
Storage temperature –40℃ to +70℃
Working humidity ≤85%RH (Non-condensing)
Physical Drop resistance 1.5m
Product Weight 0.28kg
Product Size (L x W x H) 19.3 x 5.9 x 7.7cm
Package Weight 0.485kg

9. User Tips

  • Emissivity Matters: Always try to set the correct emissivity for the material you are inspecting. Incorrect emissivity is a common cause of inaccurate temperature readings.
  • Optimal Distance: For the most accurate measurements, operate the camera within its specified temperature measuring focal length of 0.3m to 3m.
  • Palette Choice: Experiment with different color palettes to find the one that best highlights the temperature differences relevant to your inspection. Some palettes are better for subtle changes, while others emphasize extreme temperatures.
  • Documentation: Utilize the image storage feature to document your findings. Transfer images regularly to your computer for detailed analysis and record-keeping.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.