VaneAims FXB-VA Series Voltage Relay Protector

Contents

VaneAims FXB-VA Series Voltage Relay Protector User Manual

Adjustable Over Voltage, Under Voltage, and Overcurrent Protective Device

1. Introduction

The VaneAims FXB-VA Series Voltage Relay Protector is a versatile device designed to safeguard electrical equipment and home appliances from voltage and current abnormalities. It offers protection against overvoltage, undervoltage, and overcurrent conditions, with various models providing additional features such as kWh, Watt, and Frequency measurement. This manual provides detailed instructions for installation, operation, and parameter settings for all available versions.

Two VaneAims Voltage Current Protectors, one Regular Version and one kWh Version, showing digital displays and buttons.
Figure 1: VaneAims Voltage Current Protectors (Regular and kWh Versions)

2. Safety Information

WARNING: Disconnect the power supply before wiring.

  • Installation must be performed by qualified electricians.
  • All electrical connections must comply with appropriate safety standards.
  • Ensure proper grounding if required by local regulations.
  • Do not operate the device with wet hands or in damp conditions.
  • Do not attempt to repair or modify the device yourself. Contact qualified personnel for service.

3. Product Overview and Features

The FXB-VA Series offers multiple versions to suit different measurement and protection needs. All models are designed for 35mm DIN rail mounting, making them suitable for installation in household distribution boxes.

Four versions of the VaneAims protector: Regular, Upgraded, kWh, and All-in-One, showing their respective displays.
Figure 2: Different versions of the VaneAims Voltage Relay Protector

3.1. Version Feature Comparison

FunctionRegular VersionUpgraded VersionkWh VersionAll-in-One Version
Over-voltage protection✔✔✔✔
Under-voltage protection✔✔✔✔
Over-current protection✔✔✔✔
Automatic recovery✔✔✔✔
Voltage display (voltage measurement)✔✔✔✔
Current display (current measurement)✔✔✔✔
Electricity Display (KWH)✖✖✔✔
Power Display (W)✖✖✖✔
Frequency Display (Hz)✖✖✖✔
Overcurrent counter✖✖✖✔
Preset Power Level✖✖✖✔
Quick power down protection✖✖✖✔
Password setting✔✔✔✔

Note: ✔ = Yes (Support), ✖ = No (Not Support)

Detailed comparison table of features across Regular, Upgraded, kWh, and All-in-One versions of the VaneAims protector.
Figure 3: Detailed Feature Comparison Table

4. Technical Specifications

The following table outlines the general technical specifications for the VaneAims FXB-VA Series. Specific voltage and current ranges may vary slightly between models as noted.

ParameterRegular/Upgraded VersionkWh/All-in-One Version
Supply terminalsN, LN, L
Rated supply voltageAC 220VAC 220V
Rated frequency40/50/60/70Hz50/60Hz
>V setting range (Overvoltage)AC 130-300VAC 240-300V
<V setting range (Undervoltage)AC 80-210VAC 140-230V
Voltage hysteresis5V5V
Overvoltage trip delay0.5s0.5s
Voltage accuracy<1%<1%
Max. operating phase voltage350V350V
Max. operating current40A/63A/80A40A/63A/80A/100A
Altitude≤2000m≤2000m
Delay time (Recovery Delay)5-300s5-300s
Permissible relative humidity≤50% at 40°C (without condensation)≤50% at 40°C (without condensation)
Ambient temperature-25°C ~ +55°C-25°C ~ +55°C
Size81*36*66mm81*36*66mm
Technical specifications table for VaneAims Voltage Relay Protectors.
Figure 4: Technical Data for Regular/Upgraded Versions
Technical specifications table for VaneAims Voltage Relay Protectors, including kWh and All-in-One versions.
Figure 5: Technical Data for kWh/All-in-One Versions

5. Setup and Installation

5.1. DIN Rail Mounting

The protector is designed for 35mm DIN rail installation. It can be easily placed in standard household distribution boxes, equivalent in size to a regular 2P circuit breaker.

VaneAims protector mounted on a 35mm DIN rail inside a distribution box.
Figure 6: 35mm DIN Rail Installation

5.2. Wiring Diagram

Ensure the power supply is disconnected before proceeding with wiring. Connect the power line (Live and Neutral) to the 'IN' terminals and the load to the 'OUT' terminals. When inputting the power line through L and N, screw down to penetrate the insulating layer of the power lines.

Wiring diagram showing the connection of the VaneAims protector between a power switch and an air circuit breaker.
Figure 7: Easy Wiring Diagram (L: Live line, N: Null line)

6. Operating Instructions

6.1. Front Panel and Button Functions

The device features a digital display and control buttons for setting parameters and monitoring. The display shows real-time voltage, current, and other parameters depending on the version.

Close-up of the VaneAims protector's front panel showing the digital display, indicators, and control buttons.
Figure 8: Function Button Display (Regular Version)
  • SET Button: Used to enter the setting menu and confirm selections.
  • Up/Digit+ Button (▲): Used to increase values or navigate up in the menu.
  • Down/Digit- Button (▼): Used to decrease values or navigate down in the menu.
  • ON/OFF Button (Power Symbol): Used to manually turn the device on/off.
  • Indicators:
    - >V: Overvoltage Indicator
    - <V: Undervoltage Indicator
    - >A: Overcurrent Indicator
    - POWER: Normal Working Indicator

6.2. Parameter Setting

To enter the setting state, press and hold the SET key for 5 seconds. Use the Up (▲) and Down (▼) keys to adjust values. Press the SET key again to save the changes and exit the setting mode. To quickly adjust figures for longer periods, press and hold the Up or Down key.

6.2.1. Regular/Upgraded Version Settings (FXB-VA/FXB-VALG)

Setup menu for the Regular Version of the VaneAims protector, detailing parameters P-1 to P-5.
Figure 9: Regular Version Setup Menu (P-1 to P-5)

The setup menu for Regular/Upgraded versions includes parameters P-1 to P-19. Here are some key settings:

  • P-1: Power-on delay time (1s-999s)
  • P-2: Recovery delay (1s-999s)
  • P-3: Overvoltage Setting (130V-300V)
  • P-4: Overvoltage recovery value (125V-295V)
  • P-5: Undervoltage Setting (80V-210V)
  • P-6: Undervoltage recovery value (85V-215V)
  • P-9: Overcurrent Setting (40A/63A/80A)
  • P-19: Password setting (000-999). Factory default: 112.
Full product setting menu for the VaneAims protector, showing parameters P-1 to P-19.
Figure 10: Full Product Setting Menu (Regular/Upgraded)

6.2.2. kWh Version Settings (FXB-VAKWH)

Setup menu for the kWh Version of the VaneAims protector, detailing parameters P-1 to P-8.
Figure 11: kWh Version Setup Menu

The kWh version includes settings for electricity metering. Key settings include:

  • P-1: Overvoltage Setting (240-300V)
  • P-2: Overvoltage delay time (5-300s)
  • P-3: Undervoltage Setting (140-230V)
  • P-4: Undervoltage delay time (5-300s)
  • P-5: Overcurrent Setting (40A/63A/80A/100A)
  • P-8: Show kWh (Reset Power: contact supplier)
kWh version parameter setting menu showing P-1 to P-8.
Figure 12: kWh Version Parameter Setting

6.2.3. All-in-One Version Settings (FXB-VA5+1)

Setup menu for the All-in-One Version of the VaneAims protector, detailing parameters P-1 to P-13.
Figure 13: All-in-One Version Setup Menu

The All-in-One version offers comprehensive monitoring and protection. Key settings include:

  • P-1: Power-on Delay Time (1s-999s)
  • P-2: Recovery Delay (1s-999s)
  • P-3: Overvoltage Setting (230V-300V)
  • P-4: Undervoltage Setting (80V-210V)
  • P-5: Voltage Trip Delay (0.1s-10s)
  • P-6: Voltage Correction (-9.5%~+9.5%V)
  • P-7: Overcurrent Setting (1A-63A)
  • P-8: Overcurrent Trip Delay (0.1s-10s)
  • P-9: Overcurrent Counter (0-20 times)
  • P-10: Current Adjustment (-9.5%~+9.5%A)
  • P-11: Preset Power Level (0-999)
  • P-12: Quick Power Down Protection (on/off)
  • P-13: Password Setting (000-999). Factory default: 112.

6.3. Function Test Demonstration

The following video demonstrates the overvoltage, undervoltage, and overcurrent protection functions of the device.

Video 1: Over/Undervoltage Protector Function Test. This video demonstrates how the protector disconnects the power supply when voltage or current thresholds are exceeded.

7. Maintenance

7.1. Screen Protective Film

The screen surface is covered with a factory protective film. Slight bubbles or scratches may occur during transportation. Please remove the protective film promptly after receiving the goods to achieve the best display effect.

Image showing a hand peeling off a protective film from the device's screen, with a usage tip.
Figure 14: Screen Protective Film Removal

7.2. General Care

  • Keep the device clean and free from dust.
  • Avoid exposing the device to extreme temperatures or humidity.
  • Do not use abrasive cleaners or solvents on the device.

8. Troubleshooting

  • Device not powering on: Check wiring connections and ensure the main power supply is active.
  • Device tripping frequently: Review your set overvoltage, undervoltage, and overcurrent parameters (P-3, P-5, P-9) to ensure they are appropriate for your load and supply conditions. Adjust delay times (P-2, P-4, P-8) if necessary to prevent nuisance tripping.
  • Incorrect voltage/current readings: Ensure proper wiring. If the issue persists, consider using the voltage/current correction parameters (P-6, P-10 in All-in-One version) if available on your model.
  • Cannot reset kWh value (kWh/All-in-One versions): For some models, resetting the cumulative power consumption (kWh) may require contacting the supplier or referring to advanced settings (e.g., P-8 in kWh version manual states 'Reset Power: contact the supplier').
  • Screen display issues: Ensure the protective film is removed.

9. User Tips

  • Easy Parameter Adjustment: Users have found setting parameters to be very easy. Take advantage of this to customize protection levels for different applications, such as adjusting current limits for various campsite power supplies (e.g., 6A for one, 10A for another).
  • Verify Settings: After setting parameters, double-check them to ensure they match your specific requirements for overvoltage, undervoltage, and overcurrent protection.

10. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact your seller. The product is certified by CE and RoHS, ensuring compliance with European safety and environmental standards.

Certificates of Conformity for CE and RoHS for the VaneAims product.
Figure 15: Certified by CE/RoHS

A user manual in PDF format is available for download: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.