1. Introduction
The VaneAims FXB-VA Series Voltage Relay Protector is a versatile device designed to safeguard electrical equipment and home appliances from voltage and current abnormalities. It offers protection against overvoltage, undervoltage, and overcurrent conditions, with various models providing additional features such as kWh, Watt, and Frequency measurement. This manual provides detailed instructions for installation, operation, and parameter settings for all available versions.

2. Safety Information
WARNING: Disconnect the power supply before wiring.
- Installation must be performed by qualified electricians.
- All electrical connections must comply with appropriate safety standards.
- Ensure proper grounding if required by local regulations.
- Do not operate the device with wet hands or in damp conditions.
- Do not attempt to repair or modify the device yourself. Contact qualified personnel for service.
3. Product Overview and Features
The FXB-VA Series offers multiple versions to suit different measurement and protection needs. All models are designed for 35mm DIN rail mounting, making them suitable for installation in household distribution boxes.

3.1. Version Feature Comparison
| Function | Regular Version | Upgraded Version | kWh Version | All-in-One Version |
|---|---|---|---|---|
| Over-voltage protection | ✔ | ✔ | ✔ | ✔ |
| Under-voltage protection | ✔ | ✔ | ✔ | ✔ |
| Over-current protection | ✔ | ✔ | ✔ | ✔ |
| Automatic recovery | ✔ | ✔ | ✔ | ✔ |
| Voltage display (voltage measurement) | ✔ | ✔ | ✔ | ✔ |
| Current display (current measurement) | ✔ | ✔ | ✔ | ✔ |
| Electricity Display (KWH) | ✖ | ✖ | ✔ | ✔ |
| Power Display (W) | ✖ | ✖ | ✖ | ✔ |
| Frequency Display (Hz) | ✖ | ✖ | ✖ | ✔ |
| Overcurrent counter | ✖ | ✖ | ✖ | ✔ |
| Preset Power Level | ✖ | ✖ | ✖ | ✔ |
| Quick power down protection | ✖ | ✖ | ✖ | ✔ |
| Password setting | ✔ | ✔ | ✔ | ✔ |
Note: ✔ = Yes (Support), ✖ = No (Not Support)

4. Technical Specifications
The following table outlines the general technical specifications for the VaneAims FXB-VA Series. Specific voltage and current ranges may vary slightly between models as noted.
| Parameter | Regular/Upgraded Version | kWh/All-in-One Version |
|---|---|---|
| Supply terminals | N, L | N, L |
| Rated supply voltage | AC 220V | AC 220V |
| Rated frequency | 40/50/60/70Hz | 50/60Hz |
| >V setting range (Overvoltage) | AC 130-300V | AC 240-300V |
| <V setting range (Undervoltage) | AC 80-210V | AC 140-230V |
| Voltage hysteresis | 5V | 5V |
| Overvoltage trip delay | 0.5s | 0.5s |
| Voltage accuracy | <1% | <1% |
| Max. operating phase voltage | 350V | 350V |
| Max. operating current | 40A/63A/80A | 40A/63A/80A/100A |
| Altitude | ≤2000m | ≤2000m |
| Delay time (Recovery Delay) | 5-300s | 5-300s |
| Permissible relative humidity | ≤50% at 40°C (without condensation) | ≤50% at 40°C (without condensation) |
| Ambient temperature | -25°C ~ +55°C | -25°C ~ +55°C |
| Size | 81*36*66mm | 81*36*66mm |


5. Setup and Installation
5.1. DIN Rail Mounting
The protector is designed for 35mm DIN rail installation. It can be easily placed in standard household distribution boxes, equivalent in size to a regular 2P circuit breaker.

5.2. Wiring Diagram
Ensure the power supply is disconnected before proceeding with wiring. Connect the power line (Live and Neutral) to the 'IN' terminals and the load to the 'OUT' terminals. When inputting the power line through L and N, screw down to penetrate the insulating layer of the power lines.

6. Operating Instructions
6.1. Front Panel and Button Functions
The device features a digital display and control buttons for setting parameters and monitoring. The display shows real-time voltage, current, and other parameters depending on the version.

- SET Button: Used to enter the setting menu and confirm selections.
- Up/Digit+ Button (▲): Used to increase values or navigate up in the menu.
- Down/Digit- Button (▼): Used to decrease values or navigate down in the menu.
- ON/OFF Button (Power Symbol): Used to manually turn the device on/off.
- Indicators:
- >V: Overvoltage Indicator
- <V: Undervoltage Indicator
- >A: Overcurrent Indicator
- POWER: Normal Working Indicator
6.2. Parameter Setting
To enter the setting state, press and hold the SET key for 5 seconds. Use the Up (▲) and Down (▼) keys to adjust values. Press the SET key again to save the changes and exit the setting mode. To quickly adjust figures for longer periods, press and hold the Up or Down key.
6.2.1. Regular/Upgraded Version Settings (FXB-VA/FXB-VALG)

The setup menu for Regular/Upgraded versions includes parameters P-1 to P-19. Here are some key settings:
- P-1: Power-on delay time (1s-999s)
- P-2: Recovery delay (1s-999s)
- P-3: Overvoltage Setting (130V-300V)
- P-4: Overvoltage recovery value (125V-295V)
- P-5: Undervoltage Setting (80V-210V)
- P-6: Undervoltage recovery value (85V-215V)
- P-9: Overcurrent Setting (40A/63A/80A)
- P-19: Password setting (000-999). Factory default: 112.

6.2.2. kWh Version Settings (FXB-VAKWH)

The kWh version includes settings for electricity metering. Key settings include:
- P-1: Overvoltage Setting (240-300V)
- P-2: Overvoltage delay time (5-300s)
- P-3: Undervoltage Setting (140-230V)
- P-4: Undervoltage delay time (5-300s)
- P-5: Overcurrent Setting (40A/63A/80A/100A)
- P-8: Show kWh (Reset Power: contact supplier)

6.2.3. All-in-One Version Settings (FXB-VA5+1)

The All-in-One version offers comprehensive monitoring and protection. Key settings include:
- P-1: Power-on Delay Time (1s-999s)
- P-2: Recovery Delay (1s-999s)
- P-3: Overvoltage Setting (230V-300V)
- P-4: Undervoltage Setting (80V-210V)
- P-5: Voltage Trip Delay (0.1s-10s)
- P-6: Voltage Correction (-9.5%~+9.5%V)
- P-7: Overcurrent Setting (1A-63A)
- P-8: Overcurrent Trip Delay (0.1s-10s)
- P-9: Overcurrent Counter (0-20 times)
- P-10: Current Adjustment (-9.5%~+9.5%A)
- P-11: Preset Power Level (0-999)
- P-12: Quick Power Down Protection (on/off)
- P-13: Password Setting (000-999). Factory default: 112.
6.3. Function Test Demonstration
The following video demonstrates the overvoltage, undervoltage, and overcurrent protection functions of the device.
7. Maintenance
7.1. Screen Protective Film
The screen surface is covered with a factory protective film. Slight bubbles or scratches may occur during transportation. Please remove the protective film promptly after receiving the goods to achieve the best display effect.

7.2. General Care
- Keep the device clean and free from dust.
- Avoid exposing the device to extreme temperatures or humidity.
- Do not use abrasive cleaners or solvents on the device.
8. Troubleshooting
- Device not powering on: Check wiring connections and ensure the main power supply is active.
- Device tripping frequently: Review your set overvoltage, undervoltage, and overcurrent parameters (P-3, P-5, P-9) to ensure they are appropriate for your load and supply conditions. Adjust delay times (P-2, P-4, P-8) if necessary to prevent nuisance tripping.
- Incorrect voltage/current readings: Ensure proper wiring. If the issue persists, consider using the voltage/current correction parameters (P-6, P-10 in All-in-One version) if available on your model.
- Cannot reset kWh value (kWh/All-in-One versions): For some models, resetting the cumulative power consumption (kWh) may require contacting the supplier or referring to advanced settings (e.g., P-8 in kWh version manual states 'Reset Power: contact the supplier').
- Screen display issues: Ensure the protective film is removed.
9. User Tips
- Easy Parameter Adjustment: Users have found setting parameters to be very easy. Take advantage of this to customize protection levels for different applications, such as adjusting current limits for various campsite power supplies (e.g., 6A for one, 10A for another).
- Verify Settings: After setting parameters, double-check them to ensure they match your specific requirements for overvoltage, undervoltage, and overcurrent protection.
10. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact your seller. The product is certified by CE and RoHS, ensuring compliance with European safety and environmental standards.

A user manual in PDF format is available for download: View User Manual (PDF)