ELECTESLA ES510

Contents

ELECTESLA ES510 IGBT VFD Inverter User Manual

Model: ES510

1. Introduction

The ELECTESLA ES510 IGBT Variable Frequency Drive (VFD) Inverter is a high-performance device designed for precise motor speed control in various industrial applications. Utilizing advanced IGBT module technology, it offers robust and efficient operation for 3-phase motors. This manual provides essential information for the safe and effective installation, operation, and maintenance of your ES510 VFD.

ELECTESLA ES510 IGBT VFD Inverter with key specifications
Figure 1: ELECTESLA ES510 IGBT VFD Inverter, highlighting 4/5.5KW power, 380V input/output, 0-3200Hz output frequency, MPPT function, and 24 months warranty.

2. Safety Information

Please read and understand all safety instructions before installing, operating, or performing maintenance on the VFD. Failure to comply with these instructions may result in serious injury or equipment damage.

  • Only qualified personnel should install, operate, and maintain this equipment.
  • Always disconnect power before performing any work on the VFD or connected motor.
  • Ensure proper grounding of the VFD and motor.
  • Do not touch electrical components when power is applied.
  • Verify input voltage matches the VFD's specifications.
  • Install the VFD in a clean, dry, and well-ventilated environment, away from direct sunlight, corrosive gases, and flammable materials.
  • Do not operate the VFD with damaged cables or components.

3. Specifications

3.1. General Specifications

AttributeValue
Brand NameELECTESLA
Model NumberES510
TypeDC/AC Inverters
Input Voltage3phase 380-440V
Output Voltage3phase 380-440V
Output Current9A/13A (depending on model variant)
Output Frequency0-3200Hz
Output TypeTriple
Weight2.8kg
Size215*131*174mm
CertificationCE
OriginMainland China
CustomizationYes

3.2. Power Range and Voltage Configurations

  • 1-Phase 220V Input, 3-Phase 220V Output: 0.75KW to 5.5KW
  • 3-Phase 220V Input, 3-Phase 220V Output: 0.75KW to 55KW
  • 3-Phase 380V Input, 3-Phase 380V Output: 0.75KW to 500KW
  • 1-Phase 220V Input, 3-Phase 380V Output: 0.75KW to 22KW

3.3. Key Features

  • Digital Inputs: 6 (X1-X6)
  • Communication: Modbus RS485
  • Brake Unit: Built-in (for 0.75-22KW models)
  • Analog Inputs: 2 (AI1: 0-10V or 0-20mA; AI2: 0-10V)
  • Analog Output: 1 (AO1: 0-10V or 0-20mA)
  • Relay Output: 1 (2 Relay Outputs optional)
  • Other Outputs: Open Collector Output
  • Special Function: MPPT (Maximum Power Point Tracking) function for solar applications.

4. Package Contents

Upon opening the package, please verify that all items are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

  • ELECTESLA ES510 IGBT VFD Inverter Unit
  • User Manual (this document)
ELECTESLA ES510 VFD Inverter in its retail packaging with user manual
Figure 2: The ES510 VFD Inverter as packaged, including the unit and its user manual.

5. Setup and Installation

5.1. Mounting

Mount the VFD vertically on a sturdy, non-flammable surface. Ensure adequate clearance around the unit for proper ventilation and heat dissipation. Avoid mounting in areas with excessive vibration, dust, or moisture.

5.2. Wiring

All wiring must comply with local and national electrical codes. Use appropriate wire gauges for the VFD's power rating. Refer to the terminal diagrams below for correct connections.

Front view of ELECTESLA ES510 VFD showing control panel and terminal block
Figure 3: Front view of the ES510 VFD, illustrating the control panel and the accessible terminal block for connections.
Close-up of the VFD terminal block for power and control wiring
Figure 4: Detailed view of the VFD's terminal block, showing clearly labeled connections for power (PE, P+, PB, R, S, T, U, V, W) and control signals (10V, AO1, 485+, 485-, X1-X6, COM, TA1, TB1, TC1, GND, Y, +24V, TA2, TB2, TC2).

Power Wiring:

  • R, S, T: Connect to the 3-phase AC power supply (380-440V).
  • U, V, W: Connect to the 3-phase motor terminals.
  • PE: Connect to earth ground.
  • P+, PB: For connecting an external braking resistor (if applicable and within the 0.75-22KW range).

Control Wiring:

The control terminal block provides connections for digital inputs, analog inputs/outputs, and relay outputs. Refer to the detailed diagram (Figure 4) for specific pin assignments.

  • Digital Inputs (X1-X6): For external control signals (e.g., start/stop, multi-speed selection).
  • Analog Inputs (AI1, AI2): For speed reference signals (e.g., potentiometer, PLC analog output). AI1 supports 0-10V or 0-20mA, AI2 supports 0-10V.
  • Analog Output (AO1): Provides an analog signal proportional to frequency, current, etc. (0-10V or 0-20mA).
  • Relay Outputs (TA1/TB1/TC1, TA2/TB2/TC2): Programmable relay contacts for status indication or external control.
  • RS485 (+, -): For Modbus communication.
  • 10V, GND, +24V: Power supplies for external control components.
Play video
Watch video online
Video 1: Product demonstration showing the removable keypad and the terminal connections of the ELECTESLA ES510 VFD Inverter.

6. Operating Instructions

6.1. Control Panel Overview

The ES510 VFD features an intuitive control panel with a digital display and several buttons:

  • Display: Shows frequency, current, voltage, and other parameters.
  • PRG (Program): Enters/exits parameter setting mode.
  • FUNC (Function): Cycles through different function menus.
  • RUN: Starts the motor.
  • STOP: Stops the motor.
  • Up/Down Arrows: Adjusts frequency, navigates menus, changes parameter values.
  • Left/Right Arrows: Navigates within menus, shifts digits during parameter entry.
  • ENTER: Confirms selections and saves parameter changes.

6.2. Basic Operation

  1. Power On: Apply 3-phase 380-440V AC power to the R, S, T terminals. The display will light up.
  2. Frequency Setting: Use the Up/Down arrow keys to adjust the desired output frequency.
  3. Start Motor: Press the RUN button. The motor will accelerate to the set frequency.
  4. Stop Motor: Press the STOP button. The motor will decelerate and stop.
  5. Parameter Adjustment: Press PRG to enter parameter mode. Use arrow keys to navigate and ENTER to select/confirm. Refer to the full user manual for detailed parameter descriptions.

6.3. Advanced Features

  • MPPT Function: For solar pump applications, the VFD can track the maximum power point of solar panels to optimize pump performance.
  • Modbus RS485: Allows remote control and monitoring of the VFD via a Modbus communication network.
  • Multi-speed Control: Configure digital inputs (X1-X6) for pre-set multi-speed operation.

7. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your VFD.

  • Daily Inspection: Check for unusual noises, vibrations, or odors. Monitor the display for any error codes.
  • Weekly Cleaning: Gently clean the exterior of the VFD with a soft, dry cloth. Ensure ventilation openings are free from dust and debris.
  • Monthly Inspection: Check all wiring connections for tightness. Inspect cooling fans for proper operation and cleanliness.
  • Annual Inspection: Have a qualified technician perform a thorough inspection, including checking capacitor health and insulation resistance.

Always disconnect power before performing any cleaning or inspection inside the VFD.

8. Troubleshooting

This section provides solutions to common issues. For problems not listed here, or if solutions do not resolve the issue, contact technical support.

ProblemPossible CauseSolution
VFD does not power onNo input power; Blown fuseCheck power supply; Replace fuse (by qualified personnel)
Motor does not runIncorrect wiring; Parameter settings; Emergency stop activeVerify motor and control wiring; Check parameter settings (e.g., start source); Reset emergency stop
Overcurrent fault (OC)Motor overload; Short circuit; Rapid accelerationReduce load; Check motor/cables; Increase acceleration time parameter
Overvoltage fault (OV)High input voltage; Rapid deceleration; Regenerative loadCheck input voltage; Increase deceleration time parameter; Install braking resistor (if applicable)
Undervoltage fault (UV)Low input voltage; Power dipCheck input voltage; Ensure stable power supply
Overload fault (OL)Motor or VFD overloadedReduce mechanical load; Check motor current rating; Verify VFD capacity

9. User Tips

  • For applications requiring precise speed control, consider using an external potentiometer connected to the analog input (AI1 or AI2) for fine-tuning the frequency.
  • When integrating with a PLC or other control system, utilize the Modbus RS485 communication for efficient remote control and data acquisition.
  • If experiencing motor noise, ensure proper shielding of motor cables and consider adjusting carrier frequency parameters if available in the advanced settings.

10. Warranty and Support

The ELECTESLA ES510 IGBT VFD Inverter comes with a 24-month warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.

For technical support, inquiries, or assistance, please contact ELECTESLA Official Store:

  • WhatsApp: +8618656102087
  • Email: alex@jinqu-electric.com
Various industrial applications of VFD inverters including petroleum, water treatment, plastic industry, lifting gear, machine tools, and transmission systems.
Figure 5: Examples of industrial applications where ELECTESLA VFDs are utilized, such as petroleum, water treatment, plastic manufacturing, lifting equipment, machine tools, and general transmission systems.
Documents and downloads