Hantek 6022BL

Contents

Hantek 6022BL PC USB Oscilloscope and Logic Analyzer User Manual

Model: 6022BL | Brand: Hantek

1. Product Overview

The Hantek 6022BL is a versatile PC USB Oscilloscope and 16-Channel Logic Analyzer designed for a wide range of electrical measurement tasks. Its compact and robust design, featuring an anodized aluminum casing, ensures durability and portability. This device connects to your computer via a standard USB2.0 interface, eliminating the need for an external power source, making it ideal for on-the-go use and product line maintenance.

Key features include:

  • Excellent industrial design with anodized aluminum casing for enhanced hardness and heat resistance.
  • Standard USBXITM interface for easy integration into combination instruments.
  • USB2.0 interface for power and data, requiring no external power.
  • Compact dimensions (205x120x35mm) for easy portability.
  • High performance with 48MS/s real-time sampling and 20MHz bandwidth for oscilloscope functions.
  • Integrated 16-channel Logic Analyzer with 10MHz bandwidth.
  • Compatibility with various Windows operating systems: Windows 8, Windows 7, Windows NT, Windows 2000, Windows XP, and VISTA.
  • 23 measurement functions, including PASS/FAIL Check.
  • Advanced waveform analysis features: average, persistence, intensity, invert, addition, subtraction, multiplication, division, and X-Y plot.
  • Ability to save waveforms in multiple formats: text file, JPG/BMP graphic file, MS Excel/Word file.
  • FFT (Fast Fourier Transform) functionality.
  • Support for connecting multiple DSO units to a single computer for extended channel capabilities.
  • PID/VID Second Design instance support.
Hantek 6022BL PC USB Oscilloscope with probes and logic analyzer cables
Hantek 6022BL PC USB Oscilloscope with probes and logic analyzer cables.
Top-down view of the Hantek 6022BL oscilloscope
Top-down view of the Hantek 6022BL oscilloscope.

2. Setup Guide

  1. **Unpack the Device**: Carefully remove the Hantek 6022BL unit and all accessories from its packaging. Verify that all components listed in the packing list are present, including the oscilloscope unit, 2 x PP80 standard probes, USB cable, logic analyzer cables, and software CD.
  2. **Software Installation**: Insert the provided software CD into your computer's optical drive. Follow the on-screen instructions to install the Hantek oscilloscope and logic analyzer software. Ensure your operating system is compatible (Windows 8, 7, NT, 2000, XP, VISTA). If a CD drive is unavailable, check the official Hantek website for software downloads.
  3. **Connect to PC**: Connect the Hantek 6022BL to your computer using the supplied USB2.0 cable. The device is powered via the USB connection, so no external power adapter is needed.
  4. **Driver Installation**: Your operating system may automatically install the necessary drivers. If not, follow the instructions provided with the software or on the Hantek website to manually install the drivers.
  5. **Connect Probes**: For oscilloscope functions, connect the PP80 probes to the CH1 and CH2 BNC inputs on the Hantek 6022BL. For logic analyzer functions, connect the 16-channel logic analyzer cables to the dedicated input port.
  6. **Initial Power On**: Launch the Hantek software on your computer. The software should detect the connected device.
Hantek 6022BL oscilloscope with probes, USB cable, logic analyzer clips, and software CD
Included accessories for the Hantek 6022BL.
Hantek 6022BL oscilloscope with probes, USB cable, logic analyzer clips, and user guide
Hantek 6022BL and its components, including the user guide.
Hantek 6022BL oscilloscope connected to a laptop and a circuit board
Example setup: Hantek 6022BL connected to a laptop and a circuit for measurement.

3. Operating Instructions

The Hantek 6022BL operates through dedicated software installed on your PC, transforming your computer into a powerful measurement station. Refer to the software's built-in help documentation for detailed instructions on each function.

3.1 Oscilloscope Operation

  1. **Launch Software**: Open the Hantek oscilloscope application on your computer.
  2. **Select Channels**: Choose the desired input channels (CH1, CH2) for your measurement.
  3. **Adjust Settings**: Configure parameters such as vertical scale (V/div), time base (s/div), trigger type (Edge, Alternative), and trigger source (CH1, CH2, EXT, EXT/10) within the software interface.
  4. **Connect to Circuit**: Attach the oscilloscope probes to the test points on your circuit.
  5. **View Waveform**: Observe the waveform displayed on your computer screen.
  6. **Measurement Functions**: Utilize the 23 automatic measurement functions (e.g., Vpp, Frequency, Period, Rise Time) or manual cursor measurements (Cross, Trace, Horizontal, Vertical) for detailed analysis.
  7. **Waveform Analysis**: Apply mathematical operations (+, -, x, ÷, FFT, Invert) and view X-Y plots for advanced signal analysis.
  8. **Save Data**: Save captured waveforms as text files, JPG/BMP graphic files, or MS Excel/Word files for documentation and further analysis.

3.2 Logic Analyzer Operation

  1. **Launch Software**: Open the Hantek logic analyzer application (or switch to logic analyzer mode within the main software).
  2. **Connect Logic Probes**: Connect the 16-channel logic analyzer probes to the digital signals you wish to analyze.
  3. **Configure Settings**: Set the sampling rate, trigger conditions, and other relevant parameters within the software.
  4. **Capture Data**: Start the capture process to record the digital signals.
  5. **Analyze Data**: View and analyze the captured digital waveforms, identifying timing issues, protocol errors, and other digital signal characteristics.
Product overview video demonstrating the Hantek 6022BL.

4. Maintenance

To ensure the longevity and optimal performance of your Hantek 6022BL, follow these maintenance guidelines:

  • **Cleaning**: Use a soft, dry cloth to clean the exterior of the device. Avoid using abrasive cleaners or solvents, which can damage the casing and labels.
  • **Storage**: Store the device in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. Keep it in its original packaging or a protective case when not in use.
  • **Probe Care**: Handle probes carefully. Avoid bending or stressing the cables excessively. Clean probe tips gently if they become dirty.
  • **Software Updates**: Regularly check the Hantek official website for software and firmware updates to ensure you have the latest features and bug fixes.
  • **Avoid Physical Shock**: Protect the device from drops and impacts, as these can damage internal components.

5. Troubleshooting

If you encounter issues with your Hantek 6022BL, consider the following troubleshooting steps:

  • **Device Not Detected**:
    1. Ensure the USB cable is securely connected to both the device and the PC.
    2. Try a different USB port on your computer.
    3. Verify that the drivers are correctly installed. Reinstall them if necessary.
    4. Restart your computer and the Hantek software.
  • **No Waveform Display**:
    1. Check probe connections to the device and the circuit under test.
    2. Ensure the input signal is within the device's voltage range.
    3. Adjust the vertical scale (V/div) and time base (s/div) settings in the software.
    4. Verify that the trigger settings are appropriate for the signal being measured.
  • **Software Crashes/Freezes**:
    1. Ensure your operating system meets the minimum requirements.
    2. Update the Hantek software to the latest version.
    3. Close other demanding applications running on your PC.
  • **Inaccurate Measurements**:
    1. Perform a self-calibration if available in the software.
    2. Check probe compensation (if applicable) and ensure probes are correctly set to 1X or 10X.
    3. Ensure proper grounding of the device and the circuit.

For persistent issues, consult the detailed user manual (PDF) or contact Hantek technical support.

6. Specifications

CategoryParameterValue
Oscilloscope FeaturesBandwidth20MHz
Channel2 (Digital)
Sample Rate48MSa/s
Memory Depth1M
Rise Time17.5ns
Time Base Precision±50ppm
Time Base Range4ns/div - 1h/div (Step by 1-2-4)
Input Impedance1MΩ 25pF
Input Sensitivity10mV/div ~ 5V/div
Vertical Resolution8Bit
Vertical Position Range10mV ~ 5V/div @ x1 probe; 100mV ~ 50V/div @ x10 probe; 1V ~ 500V/div @ x100 probe; 10V ~ 5KV/div @ x1000 probe
DC Accuracy±3%
Bandwidth Limited20MHz
Trigger TypeEdge, Alternative
Trigger SourceCH1, CH2, EXT, EXT/10
Logic Analyzer FeaturesChannel16
Max. Impedance1MΩ (C=7.5pF)
Max. Voltage0V ~ 5.5V
Max. Sample48M
Bandwidth10MHz
Compatible InputTTL, LVTTL, CMOS
Memory Depth1M/CH
General FeaturesPowerUSB Port
Dimensions205mm (L) x 120mm (W) x 35mm (H)
Weight0.3KG
Standard Probe2 x PP80

7. User Tips

  • **Grounding is Key**: Always ensure proper grounding of both the oscilloscope and the circuit under test to prevent measurement errors and potential damage.
  • **Probe Compensation**: If your probes are adjustable, perform probe compensation to ensure accurate signal representation, especially for high-frequency measurements.
  • **Software Familiarization**: Spend time exploring all features of the Hantek software. Many advanced functions can significantly enhance your analysis capabilities.
  • **USB Port Quality**: Use a high-quality USB 2.0 port and cable to ensure stable data transfer and power supply. Avoid using unpowered USB hubs if possible.
  • **Environmental Conditions**: Operate the device within recommended temperature and humidity ranges to maintain performance and prevent damage.

8. Warranty and Support

For detailed warranty information and technical support, please refer to the official Hantek documentation or contact the seller, EVERGOOD INSTRUMENTS Store. A comprehensive user manual in PDF format is available for download or viewing:

View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.