Important Safety Information

WARNING!

The Meross EM06P needs to be installed in the electrical panel of a home and operates in an environment that may pose a risk of injury or electric shock. Meross recommends that the unit be installed by a licensed professional electrician or other qualified professional in accordance with the electrical codes for the area in which it is to be used.

Incorrect installation and incorrect use of the equipment may result in electrical safety injuries. Meross shall not be liable to any person or third party for direct or indirect injuries and damages resulting from failure to comply with the following safety guidelines.

  • Always wear Personal Protective Equipment (PPE) when installing the Meross EM06P.
  • Only use the Meross EM06P as specified in this installation guide and avoid any other usage.
  • If you suspect any damage to the Meross EM06P equipment, do not attempt to use it.
  • Avoid installing the Meross EM06P in humid environments and keep it away from direct sunlight.
  • Make sure the Meross EM06P is not connected to the power supply during any manual processes, such as installation or removal.
  • The current transformer (CT) is rated at 120 A and saturated at 150 A. The current to be detected will be limited to a maximum of 150 A.

Package Content

Ensure all items are present before beginning installation:

  • 1 x Smart Energy Monitor (EM06P)
  • 3 or 6 x Current Transformers (CT)
  • 1 x Power Harness
  • 1 x Quick Installation Guide (this document)
Meross EM06P Smart Energy Monitor and accessories in box
Meross EM06P Smart Energy Monitor and included accessories.

Setup and Installation

Play video
Watch video online
Instructional video demonstrating the installation and pairing process for the Meross EM06P Smart Energy Monitor. This video shows how to safely de-energize your electrical panel, connect the power harness and current transformers, and pair the device with the Meross app.

1. Preparation for Installation

Before starting the installation process, it is essential to turn off the main circuit breaker in your electrical panel. This will ensure that the panel where you plan to install the equipment is completely de-energized and safe to work with.

Additionally, make sure to allocate enough space in the electrical panel for the equipment. This will allow for easy mounting on DIN rails.

Step 1: Deactivate Main Circuit Breaker

Hand turning off a main circuit breaker in an electrical panel.
Within your electrical panel, deactivate the main circuit breaker to disengage all circuits in your residence.

2. Power Harness Connection

Insert the power harness into the designated side of the monitor, ensuring a secure and proper connection. It should snap into place. The power harness is designed to support the capture of single-phase and three-phase voltages while providing power to the EM06P device.

Hands connecting the power harness to the Meross EM06P energy monitor.
Connect the power harness to the top of the energy monitor until it snaps securely into place. Also connect the audio jack to the audio jack port located on the side of the Energy Monitor.

3. Wire Connection

Please correctly determine whether the line you are monitoring is three-phase, two-phase, or single-phase.

Wire Connection Correspondence Table:

Wire ColorFunction
WhiteConnects to the neutral wire
BlackProvides power and voltage sensing (C1, C2)
GreenEnables voltage sensing only (B1, B2)
RedEnables voltage sensing only (A1, A2)

a. Single-phase circuit:

In a single-phase circuit, all 6 current transformers (CTs) have the same voltage, allowing you to monitor any 6 lines in the electrical panel. Connect all three wires (Red, Green, Black) to the same terminal block.

Wiring diagram for a single-phase circuit showing all three voltage sensing wires connected to one terminal block.
Wiring for a single-phase circuit. All three voltage sensing wires (red, green, black) are connected to the same terminal block, with the white wire connected to neutral.

b. Two-phase circuit:

When monitoring a two-phase circuit, it is crucial to ensure the correct correspondence between the voltage lines and the current ports listed in the table above. Failing to establish the correct matching relationship may result in inaccurate consumption metering results.

Wiring diagram for a two-phase circuit.
Wiring diagram for a two-phase circuit. Ensure correct voltage line to current port correspondence.

c. Three-phase circuit:

When monitoring a three-phase circuit, it is crucial to ensure the correct correspondence between the voltage lines and the current ports listed in the table above. Failing to establish the correct matching relationship may result in inaccurate consumption metering results.

Wiring diagram for a three-phase circuit.
Wiring diagram for a three-phase circuit. Ensure correct voltage line to current port correspondence.

4. Installation of Current Transformers (CTs)

Attach each CT clip securely to the hot leg of the circuit breaker you wish to monitor. Ensure the current transformer is correctly matched with its respective voltage collection line.

Install the transformer on the load line. The arrow on the transformer shows the direction of the current, K to L.

Hands attaching a CT clip to a circuit breaker in an electrical panel.
Attaching a CT clip to the hot leg of a circuit breaker. The arrow on the CT indicates the direction of current flow (K to L).

Connection Correspondence Table for CTs:

Voltage LineCurrent Transformer
Red LineA1, A2
Green LineB1, B2
Black LineC1, C2

Load Correspondence Table (for reference only, please refer to your specific situation):

CT ChannelExample Load
A1Living Room
A2Kitchen
B1Master Bedroom
B2Second Bedroom
C1Charging Post
C2Courtyard

5. Restore Power

Restore power to all circuits by closing the electrical panel box and turning on all circuit breakers that were turned off during installation.

Hand turning on circuit breakers in an electrical panel.
Restore power by turning on all circuit breakers.

The unit's green LED will begin to flash slowly after a duration of 2 seconds, indicating it's ready for pairing.

Close-up of the Meross EM06P with a slowly flashing green LED.
The green LED on the Meross EM06P will flash slowly when ready for pairing.

6. Set up the Device (App Configuration)

  1. Before pairing, please download the latest version of the Meross app from the App Store or Google Play.
  2. Turn on your phone's Bluetooth.
  3. Launch the Meross app and log in to your account, or if you are a new user, tap Sign up to create a new account.
  4. Click the plus icon (+) in the upper right corner of the app. The software will automatically search for the EM06P.
  5. Click "Add" to connect the device.
  6. Select an available 2.4G Wi-Fi network and enter the password to connect the EM06P to the Internet.
  7. Once connected, the Meross app will show "Congratulations! Your Smart Energy Monitor is successfully installed."
  8. From the Meross homepage, click on "Smart Energy Monitor" to see an overview of the power consumption data.
  9. Click on one of the items to view detailed power consumption data.

Note: This smart device needs to be set up via Bluetooth. Please make sure the Meross app is granted access to required system permissions and the Bluetooth of your smartphone has been enabled.

Screenshots of the Meross app showing device setup and energy monitoring data.
Screenshots illustrating the Meross app setup process and how to view energy consumption data.

Operating the Device

Once installed and configured, the Meross EM06P provides real-time and historical energy consumption data through the Meross app.

  • Real-Time Monitoring: View current power consumption for each monitored circuit.
  • Historical Reporting: Access minute-by-minute, hourly, daily, and monthly power usage data to optimize energy consumption and reduce electricity costs.
  • Consumption Alarm: Set alarms for consumption thresholds.
  • Data Storage: Enjoy 5 years of free data storage, with local and cloud options.
  • Data Export: The app supports data export by day/hour/minute, and up to 5 years of daily-level data. No subscription required.
Meross app displaying live and historical energy consumption data.
The Meross app provides live and historical energy consumption reports, helping users optimize energy usage.
Meross app showing 6-channel circuit monitoring with icons for various appliances.
The Meross EM06P supports 6-channel circuit monitoring, allowing simultaneous tracking of multiple single-phase circuits.

Home Assistant Integration: For advanced users, the EM06P supports integration with Home Assistant. Refer to the official documentation for the full setup guide: https://github.com/Meross-Tech/meross_rpc. Home Assistant version required: 2025.2.5 or above.

Meross EM06P integrated with Home Assistant for PV system energy management.
Smarter Automations with Home Assistant: Use EM06P with your PV system to route surplus energy into the battery, enabling zero feed-in.

Maintenance

The Meross EM06P is designed for long-term, maintenance-free operation. However, consider the following:

  • Firmware Updates: Ensure your device's firmware is up to date for optimal performance and new features. The app will notify you of available updates.
  • Cleaning: If necessary, gently wipe the device with a dry, soft cloth. Do not use liquid cleaners or solvents.
  • Environmental Conditions: Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.

Troubleshooting (FAQ)

Why can't the Meross app find my device after I installed EM06P?

  • Check that the main circuit breaker is on.
  • Check that the circuit breaker supplying power to the EM06P is turned on.
  • Check if the device LED is blinking slowly in green (once every 0.5s). If not, press and hold the button for 10s to reset and try again.
  • Make sure that your phone is authorized for the Meross app and has Bluetooth turned on.

Why is the Meross app unable to obtain real-time current and consumption data from the EM06P?

  • Check that the current transformer is securely plugged into the monitor.
  • Check that the cable with the transformer clipped to it is not working with a load device.

Why is the reading of the sales volume in the Meross app showing as a negative number?

It may be due to the CT sensor's direction being reversed. Reversing the direction of the CT sensor should resolve the issue. The correct wiring direction is when the current direction matches the direction indicated on the CT sensor (K->L). In the correct wiring configuration, a positive value indicates power consumption by appliances, while a negative value indicates generation (such as monitoring home power generation devices, etc.).

LED Rules:

  • Green light blinking: The device is in pairing mode. To connect, ensure Bluetooth is turned on and use the Meross app to discover your device. Firmware upgrade is currently in progress.
  • Red light continuously on: The device is connected to the router, but the router does not currently have an available network connection.
  • Red light blinking: Your device is disconnected from the router. Please check the router connection and ensure it is properly connected.

Button Function:

Press and hold the button for 10 seconds and then release the button. The device will reset. The device will enter pairing mode after completing the reset, and the green light will blink.

Technical Specifications

  • Power Supply: 100-240V~
  • Voltage-current Correspondence:
    • Red -> A1, A2
    • Green -> B1, B2
    • Black -> C1, C2, Power
  • CT Range: Maximum 120A for single line
  • Dimensions (W x D x H): 7.3 x 5.2 x 2.45 cm (Monitor size)
  • CT Line Length: 90 cm
  • Wireless Communication: Wi-Fi
  • Power Source: AC
  • Battery Included: No (No Need)
  • Inbox Adaptor: Yes
  • Communication Method: Wi-Fi
  • Plug Type: EU Plug (for the provided SKU, but general product supports AC)
  • Origin: Mainland China
  • Item Weight: 740g
  • Three-Phase Power Support: Support

Operating Frequency

No restrictions exist in the use of radio frequencies or frequency bands in all EU member states, EFTA countries, Northern Ireland, and Great Britain.

  • Operating Frequency / Max Output Power: 2400MHz~2483.5MHz/20dBm.

User Tips

  • Professional Installation: While the instructions are provided, some users found installation easier with the help of an electrician, especially for complex wiring.
  • Accurate Readings: Ensure CT sensors are correctly oriented (K->L arrow) to avoid negative readings, which indicate reversed direction.
  • App Features: The Meross app provides detailed hourly, daily, and monthly measurements, and allows data export for up to 5 years without subscription.
  • Single-Phase Use: The device can be used on single-phase circuits by connecting all three voltage sensing wires to the same terminal block.

Warranty and Support

Meross products are covered by a 24-month limited warranty from the date of its original purchase. If any problems occur, please contact Meross support.

For further assistance or questions during hardware installation or setup, please contact us at: https://www.meross.com/support.

Disclaimer: The function of this smart device is tested under typical circumstances described in our specifications. Meross does NOT guarantee that the smart device shall perform exactly the same as described under all circumstances. Meross's total liability is limited to what is expressly covered in its Privacy Policy. Damages arising from ignorance of the SAFETY INFORMATION shall not be covered by Meross aftersales service, nor does Meross take any legal responsibility therefrom. Customers acknowledge understanding of these articles clearly by reading this manual.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.