YAXUN YX-3010D

Contents

YAXUN YX-3010D Digital DC Power Supply

User Instruction Manual

1. Product Overview

The YAXUN YX-3010D is a professional-grade digital DC power supply designed for high-precision applications in mobile repair, electronics laboratories, and general testing. It offers adjustable voltage and current output, multi-protocol fast charging capabilities (PD/QC), USB battery simulation, and convenient memory presets for frequently used settings. This manual provides essential information for safe and effective operation.

YAXUN YX-3010D Digital DC Power Supply front and side view
Figure 1: YAXUN YX-3010D Digital DC Power Supply - Front and Side View. Features adjustable voltage (0-30V), current (0-10A), and a maximum power of 300W with regulated and stable output.

2. Safety Warnings

⚠ Critical Notes Before Use:

  • Ensure the input voltage (AC 110V or 220V) selected on the unit matches your local power supply to prevent damage to the device. Refer to the label on the rear of the power supply.
  • Do NOT block the air vents or cooling fans located on the rear and sides of the unit. Adequate ventilation is crucial for proper operation and to prevent overheating.
  • Avoid exposing the device to severe impacts, vibrations, or environments prone to static electricity.
  • Always disconnect the power cord from the mains supply before attempting any maintenance, such as replacing fuses, to prevent electric shock.
  • This device contains high voltage components. Disassembly by non-professionals is strictly prohibited.
  • Ensure the power supply is properly grounded to prevent electric shock.

3. Setup Guide

3.1 Unpacking and Inspection

Carefully remove the power supply and all accessories from the packaging. Inspect the unit for any signs of physical damage that may have occurred during transit. If any damage is found, do not operate the device and contact your supplier.

YAXUN YX-3010D with packaging and accessories
Figure 2: Package Contents - YX-3010D unit, power cord, and test leads.

3.2 Power Connection

  1. Locate the power input socket on the rear panel of the device.
  2. Verify that the voltage selector switch (if present and accessible) matches your local mains voltage (110V or 220V). The unit supports both AC 110V (US) and AC 220V (EU) at 50/60Hz.
  3. Connect the provided power cord to the power input socket and then to a grounded electrical outlet.
Rear panel of YAXUN YX-3010D showing power input and fan
Figure 3: Rear Panel - Showing the AC power input (220V indicated) and cooling fan.

3.3 Initial Power-On

Press the main power switch, usually located on the front or rear panel. The digital display should illuminate, indicating the unit is powered on and ready for operation.

4. Operating Instructions

4.1 Front Panel Controls and Indicators

Detailed diagram of the YAXUN YX-3010D front panel with numbered components
Figure 4: Front Panel Diagram with numbered components for detailed operation.

Refer to Figure 4 for the location of the following controls:

  1. DC Voltage Lock Indicator
  2. DC ON Indicator
  3. Battery Simulation Indicator
  4. Over Temperature Protection (OTP) Indicator
  5. Over Current Protection (OCP) Indicator
  6. Constant Current (CC) Mode Indicator
  7. Constant Voltage (CV) Mode Indicator
  8. DC Output Display Channel Indicator
  9. Memory Buttons (M1-M4)
  10. QC Fast Charging Port
  11. PD1 Fast Charging Port
  12. PD2 Fast Charging Port
  13. USB 5V/2A x4 Ports
  14. USB Cable Input
  15. AC Power Main Input Switch
  16. Digital Tube Display Channel Switching Button
  17. Battery USB Limit Knob (0-8.4V)
  18. Current Limit Adjustment Knob (0.1A/0.5A steps)
  19. Voltage Adjustment Knob (0.1V/0.5V steps)
  20. Output Enable/Disable Button
  21. 4MM High Current Output Terminals (Positive/Negative)
  22. Voltage Display
  23. Current Display
  24. Power (Watts) Display

4.2 Adjusting Voltage and Current

  • Voltage Adjustment: Use the "V-COARSE" knob (20) to set the desired output voltage. Short-press the knob to switch between 0.1V and 0.5V adjustment increments for precise control.
  • Current Adjustment: Use the "CURRENT" knob (18) to set the maximum output current limit. Short-press the knob to switch between 0.1A and 0.5A adjustment increments.
  • The current and voltage values are displayed on the digital readouts (22, 23).
  • The power (in Watts) is displayed on readout (24).
Video: Demonstration of voltage and current adjustment, channel switching, and stable output.

4.3 Voltage Lock Feature

To prevent accidental changes to the set voltage, long-press the "V-COARSE" knob (20). The "LOCK" indicator (1) will illuminate, signifying that the voltage setting is locked. Long-press again to unlock.

4.4 Memory Presets (M1-M4)

  • Saving Settings: Set your desired voltage and current. Long-press one of the memory buttons (M1-M4, item 9) until you hear a beep or see a confirmation on the display. The current settings are now saved to that memory channel.
  • Recalling Settings: Short-press one of the memory buttons (M1-M4, item 9) to instantly recall the saved voltage and current settings for that channel.

4.5 Multi-Protocol Fast Charging (PD/QC)

  • The unit features dedicated QC (10), PD1 (11), and PD2 (12) fast charging ports.
  • Connect compatible devices to these ports for rapid charging.
  • To view the voltage, current, and power output for these specific ports, use the "CHANNEL" button (16) to cycle through the display outputs (DC, QC, PD1, PD2). The corresponding indicator (8) will light up.

4.6 USB Battery Simulation

  • The "BAT USB LIMIT" knob (17) allows you to set a voltage limit for simulating battery power, ranging from 0 to 8.4V.
  • This feature is useful for testing devices that typically run on battery power.

4.7 Main DC Output

  • Connect your test leads to the 4MM high-current output terminals (21). Red for positive (+), black for negative (-).
  • Use the "OUT/EN" button (19) to enable or disable the main DC output. When enabled, the "DC ON" indicator (2) will be lit.

5. Maintenance

  • Cleaning: Regularly clean the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
  • Ventilation: Keep the ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating.
  • Storage: When not in use for extended periods, store the power supply in a cool, dry place away from direct sunlight and extreme temperatures.
  • Fuse Replacement: If the unit fails to power on, check the fuse located near the power input socket on the rear panel. Always replace with a fuse of the same type and rating. Ensure the power cord is disconnected before replacing.

6. Troubleshooting

Problem Possible Cause Solution
Unit does not power on. No power from outlet; power cord loose; blown fuse; main power switch off. Check power outlet; ensure power cord is securely connected; replace fuse (see Maintenance); ensure main power switch is ON.
No output from DC terminals. Output disabled; OCP/OTP activated; voltage/current set to zero. Press "OUT/EN" button to enable output; check OCP/OTP indicators and resolve overload/overheat condition; adjust voltage/current knobs to desired values.
Voltage/Current cannot be adjusted. Voltage lock engaged. Long-press the "V-COARSE" knob to unlock voltage adjustment.
Fast charging ports not working. Device not compatible with PD/QC; cable issue. Ensure device supports PD/QC; try a different cable; check if the port is selected via the "CHANNEL" button.
Unit overheats. Blocked ventilation; excessive load. Ensure vents are clear; reduce load; operate in a well-ventilated area.

7. Specifications

Feature Specification
Model YX-3010D
Input Voltage AC 110V (US) / 220V (EU), 50/60Hz
Output Voltage (DC) 0 - 30V (Adjustable)
Output Current (DC) 0 - 10A (Adjustable)
Max Power 300W
Display Type Digital LED Display (Voltage, Current, Power)
USB Output (Standard) 4 x 5V/2A
USB Output (Fast Charging) QC / PD1 / PD2 (Supports various PD/QC profiles, specific voltage profiles not detailed)
Channel Modes DC / PD1 / PD2 / QC
USB Battery Simulation 0 - 8.4V (Adjustable)
Protection Features Over Temperature Protection (OTP), Over Current Protection (OCP), High Voltage Warning
Dimensions (L×W×H) 240mm × 225mm × 188mm
Weight 4.5 kg
Origin Mainland China

8. User Tips

  • Pre-set Common Values: Utilize the M1-M4 memory channels to save frequently used voltage and current settings for quick access during repetitive tasks.
  • Monitor Power Output: The power display (in Watts) can be very useful for understanding the actual power consumption of your connected device, especially when troubleshooting or optimizing circuits.
  • Use Appropriate Cables: For the main DC output, always use high-quality test leads capable of handling the desired current to minimize voltage drop and ensure stable power delivery.
  • Check Fast Charging Compatibility: While the unit supports PD/QC, ensure your device and cable are also compatible with these protocols to achieve optimal fast charging speeds.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the YAXUN Official Store directly. Keep your purchase receipt as proof of purchase.

This product includes a firmware upgrade port for future feature updates. Please check the manufacturer's website for the latest firmware and instructions.

© 2023 YAXUN. All rights reserved.