VaneAims FXB-VA Series

Contents

VaneAims Voltage Relay 220V 40A 63A 80A Over Current Protector Instruction Manual

Model: FXB-VA Series

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the VaneAims Voltage Relay. This device is designed to protect electrical circuits from overvoltage, undervoltage, and overcurrent conditions, ensuring the safety and longevity of your electrical appliances and systems. It features a digital display for real-time monitoring and adjustable protection parameters.

The VaneAims Voltage Relay is available in several versions, each offering specific functionalities:

  • Regular Version (Model: FXB-VA) / Upgraded Version (Model: FXB-VALG): Provides overvoltage, undervoltage, and overcurrent protection.
  • kWh Version (Model: FXB-VAKWH): Includes overvoltage, undervoltage, overcurrent protection, and kWh energy measurement.
  • All-in-One Version (Model: FXB-VA5+1): Offers comprehensive protection (overvoltage, undervoltage, overcurrent) along with kWh energy measurement, Watt (W) power measurement, and Hertz (Hz) frequency measurement.

2. Key Features

  • Adjustable Over-voltage Protection
  • Adjustable Under-voltage Protection
  • Adjustable Over-current Protection
  • Real-time Voltage, Current, and (depending on version) Power, Frequency, and Energy (kWh) Display
  • Automatic Recovery Function
  • High Definition Digital Display
  • Intelligent Chip for reliable performance
  • DIN Rail Installation (35mm)
  • Flame-retardant enclosure
  • Password Lock Settings (All-in-One version)
  • Energy Saving Mode (All-in-One version)
VaneAims Voltage Relay features: Overvoltage protection, Undervoltage protection, Overcurrent protection, Intelligent chip, Automatic reset, High definition digital display.
Overview of VaneAims Voltage Relay key features.

3. Technical Specifications

Please refer to the table below for detailed specifications. Note that some parameters may vary slightly between different versions.

3.1. Regular / Upgraded Version (FXB-VA / FXB-VALG)

ParameterValue
Supply terminalsN,L
Rated supply voltageAC 220V
Rated frequency40/50/60/70Hz
>V setting range (Overvoltage)AC130-300V
<V setting range (Undervoltage)AC80-210V
Voltage hysteresis5V
Overvoltage trip delay0.5s
Voltage accuracy<1%
Max. operating phase voltage350V
Max. operating current40A/63A/80A/100A (depending on model)
Altitude≤2000m
Permissible relative humidity≤50% at 40°C (without condensation)
Ambient temperature-25°C ~ +55°C
Size81*36*66mm
Technical specifications table for Regular and Upgraded versions of VaneAims Voltage Relay.
Technical data for Regular and Upgraded versions.

3.2. kWh Version (FXB-VAKWH) / All-in-One Version (FXB-VA5+1)

ParameterValue
Supply terminalsN,L
Rated supply voltageAC 220V
Rated frequency50/60Hz
>V setting range (Overvoltage)AC240-300V
<V setting range (Undervoltage)AC140-230V
Voltage hysteresis5V
Overvoltage trip delay0.5s
Voltage accuracy<1%
Max. operating phase voltage350V
Max. operating current40A/63A/80A/100A (depending on model)
Altitude≤2000m
Delay time5-300s
Permissible relative humidity≤50% at 40°C (without condensation)
Ambient temperature-25°C ~ +55°C
Size81*36*66mm
Technical specifications table for kWh and All-in-One versions of VaneAims Voltage Relay.
Technical data for kWh and All-in-One versions.

4. Installation

Important: The product must be installed by qualified electricians. All electrical connections must comply with appropriate safety standards.

4.1. DIN Rail Mounting

The VaneAims Voltage Relay is designed for 35mm DIN rail installation, making it suitable for placement in standard household distribution boxes. Its size is equivalent to a regular 2P circuit breaker.

VaneAims Voltage Relay installed on a 35mm DIN rail in a distribution box, next to circuit breakers.
35mm DIN rail installation in a household distribution box.
Close-up of VaneAims Voltage Relay mounted on a 35mm DIN rail.
Detail of 35mm DIN rail installation.

4.2. Wiring Diagram

Connect the device according to the following wiring diagrams. Ensure proper connection of the null (N) and live (L) lines. When power line is input through L and N, screw down to penetrate the insulating layer of the power lines.

Wiring diagram showing connection of Power Switch, Voltage Protector, and Air Circuit Breaker. Null line (blue) and Live line (red) are clearly indicated.
Standard wiring diagram for the Voltage Protector.
Simplified wiring diagram for easy DIY installation, showing L and N connections.
Easy DIY wiring diagram.

5. Operating Instructions

5.1. Front Panel and Button Functions

The device features a digital display and control buttons on its front panel:

  • Display: Shows real-time Voltage (V), Current (A), and depending on the version, kWh, W, and Hz.
  • Indicators:
    • >V: Overvoltage Indicator
    • <V: Undervoltage Indicator
    • >A: Overcurrent Indicator
    • POWER: Normal Working Indicator (Green LED)
  • Buttons:
    • SET: Menu selection / Confirm setting
    • ▲ (Up/Digit+): Increase value / Navigate up
    • ▼ (Down/Digit-): Decrease value / Navigate down
    • ON/OFF (Power button): Turn the device on/off
Front panel display and button functions for the Regular/Upgraded version, showing indicators for overvoltage, undervoltage, overcurrent, normal working, and control buttons.
Front panel and button functions (Regular/Upgraded Version).
Front panel display and button functions for the kWh version, showing voltage, current, and kWh display, along with control buttons.
Front panel and button functions (kWh Version).
Front panel display and button functions for the All-in-One version, showing voltage, current, kWh, frequency, and power display, along with control buttons.
Front panel and button functions (All-in-One Version).

5.2. Setting Parameters

To enter the setup menu, press and hold the SET button for 5 seconds. Use the ▲ and ▼ buttons to adjust values, and press SET again to save and move to the next parameter. To quickly adjust figures for longer periods, press and hold either the ▲ or ▼ key.

5.2.1. Regular / Upgraded Version Settings

Setup menu for Regular/Upgraded version showing parameters P-1 to P-5 for power-on delay, recovery delay, overvoltage setting, overvoltage recovery value, and undervoltage setting.
Setup menu for Regular/Upgraded Version (P-1 to P-5).
  1. P-1 (Power-on delay time): Adjustable from 1s-999s. Default: 5s.
  2. P-2 (Recovery delay): Adjustable from 1s-999s. Default: 30s.
  3. P-3 (Overvoltage Setting): Adjustable from 130V-300V. Default: 270V.
  4. P-4 (Overvoltage recovery value): Adjustable from 125V-295V. Default: 265V.
  5. P-5 (Undervoltage Setting): Adjustable from 80V-210V. Default: 170V.

5.2.2. kWh Version Settings

Setup menu for kWh version showing parameters P-1 to P-8 for overvoltage setting, overvoltage delay, undervoltage setting, undervoltage delay, overcurrent setting, undervoltage recovery, starting delay, and show kWh.
Setup menu for kWh Version (P-1 to P-8).
  1. P-1 (Overvoltage Setting): Adjustable from 240-300V. Default: 270V.
  2. P-2 (Overvoltage delay time): Adjustable from 5-300s. Default: 30s.
  3. P-3 (Undervoltage Setting): Adjustable from 140-230V. Default: 170V.
  4. P-4 (Undervoltage delay time): Adjustable from 5-300s. Default: 30s.
  5. P-5 (Overcurrent Setting): Adjustable based on model (e.g., 63A: 1A-63A). Default: 63.0A.
  6. P-6 (Undervoltage recovery value): Adjustable from 5-300s. Default: 30s.
  7. P-7 (Starting delay time): Adjustable from 5-300s. Default: 2s.
  8. P-8 (Show kWh): Displays kWh. To reset power, contact the supplier.

5.2.3. All-in-One Version Settings

Setup menu for All-in-One version showing parameters P-1 to P-19 for various protection and measurement settings.
Setup menu for All-in-One Version (P-1 to P-19).
  1. P-1 (Power-on delay time): 1s-999s. Default: 5s.
  2. P-2 (Recovery delay): 1s-999s. Default: 30s.
  3. P-3 (Overvoltage Setting): 130V-300V. Default: 270V.
  4. P-4 (Overvoltage recovery value): 125V-295V. Default: 265V.
  5. P-5 (Undervoltage Setting): 80V-210V. Default: 170V.
  6. P-6 (Undervoltage recovery value): 85V-215V. Default: 175V.
  7. P-7 (Voltage trip delay): 0.1s-10s. Default: 0.5s.
  8. P-8 (Voltage Correction): -10%~+10%V. Default: 0.0V.
  9. P-9 (Overcurrent Setting): 40A/63A/80A/100A (e.g., 63A: 1A-63A). Default: 63.0A.
  10. P-10 (Overcurrent trip delay): 0.1s-10s. Default: 1.0s.
  11. P-11 (Overcurrent counter): 0-20 times. Default: OFF.
  12. P-12 (Current adjustment): -10%~+10%A. Default: 0.0A.
  13. P-13 (Frequency adjustment): -2.5%~+2.5%Hz. (Cannot be modified).
  14. P-14 (Quick power down protection): ON/OFF. Default: ON.
  15. P-15 (Three models): 1:Standard, 2:Manual, 3:Automatic. Default: 1.
    • Mode 1 (Standard): P1-P19 settings.
    • Mode 2 (Manual): Press up or down button to display voltage(-U-), power(-P-), current(-A-), frequency (-H-).
    • Mode 3 (Automatic): Automatically display voltage(-U-), power(-P-), current(-A-), frequency (-H-) in turn.
  16. P-16 (Automatic reset): ON/OFF. Default: ON.
  17. P-17 (Switch mode): ON/OFF. Default: ON.
  18. P-18 (Energy saving mode): ON/OFF. Default: OFF.
  19. P-19 (Password setting): 000-999. Default: 112. Change the lock parameter after the initial password is changed. Set to initial password 112 to unlock.

Note: The video below demonstrates the setting process for the I-63A (Adjustable current) model, which is similar to the All-in-One version's parameter adjustments.

Video demonstrating parameter setting for the VaneAims Voltage Relay.

6. Protection Function Testing

The device automatically trips and protects the circuit when voltage or current exceeds the set limits. It will automatically recover once the conditions return to normal (after the set recovery delay).

Video demonstrating overvoltage, undervoltage, and overcurrent protection tests.

7. Maintenance

  • Keep the device clean and free from dust.
  • Ensure proper ventilation around the device.
  • Regularly check wiring connections for tightness and signs of wear.
  • If the device malfunctions, do not attempt to repair it yourself. Contact a qualified electrician or the manufacturer for assistance.

8. Troubleshooting

If the device is not functioning as expected, consider the following:

  • Device not powering on: Check the input power supply and wiring connections.
  • Device tripping frequently: Review your set overvoltage, undervoltage, and overcurrent parameters. Ensure they are appropriate for your load and supply conditions. Check for actual voltage/current fluctuations in your system.
  • Display issues: Ensure the protective film is removed from the screen.
  • Incorrect readings: Verify wiring and ensure the device is correctly calibrated (if applicable, though calibration is usually factory set).

9. User Tips

  • Screen Protective Film: The screen surface is covered with a factory protective film. Slight bubbles or scratches may occur during transportation. Please remove the protective film promptly after receiving the goods to achieve the best display effect.
  • Customization: For bulk purchases, logo customization (ODM service) is available for the Upgraded Version. Contact the seller for details.

10. Frequently Asked Questions (FAQ)

Q: Is a Spanish instruction manual included?
A: The provided manual is in English. For other languages, please check with the seller or refer to online resources if available.

11. Certifications

This product is certified by CE and RoHS, ensuring compliance with European safety, health, and environmental protection standards.

Certificates of Conformity for CE and RoHS for the VaneAims Voltage Relay.
CE and RoHS Certifications.

12. Support and Contact

For further assistance, technical support, or inquiries regarding your VaneAims Voltage Relay, please contact the seller or refer to the official VaneAims website.

A user manual in PDF format is also available: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.