1. Product Overview
The LILYTECH ZL-7802D is a versatile temperature and humidity controller designed for applications requiring precise environmental control, such as incubators and heating systems. It features PID temperature control, support for external SSR, and comprehensive alarm functions for both temperature and humidity.


2. Package Contents
Upon unpacking, please verify that all items listed below are present and in good condition:
- 1 x ZL-7802D Temperature and Humidity Controller
- 1 x NTC Temperature Probe
- 1 x Humidity Probe
- 1 x User Manual (this document)
- 1 x Fuse
- Necessary Wiring

3. Specifications
| Feature | Specification |
|---|---|
| Model Number | ZL-7802D |
| Product Name | Temperature and Humidity Controller |
| Brand Name | LILYTECH |
| Theory | Temperature Controller |
| Type | Temperature and humidity control |
| Material | ABS Plastic (Shell: PC + ABS flame retardant) |
| Power Supply | 100-240Vac, 50/60HZ |
| Setting Range | -40.0~99.9°C, 10.0~90.0%RH |
| Temperature Sensing Element | NTC sensor, R=10KB-3470K |
| Built-in SSR Temperature Control Output (R5) | 5A, 250Vac (resistive load) |
| External SSR Temperature Control Output (Y+, Y-) | 4~20mA, 12Vdc |
| Protection Class | IP65 (Front Panel) |
| Dimensions | W78 x H34.5 x D71 (mm) |
| Mounting Hole | W71 x H29 (mm) |
| Weight | 256g (including packaging) |
| Battery Included | No |
| High-concerned chemical | None |
| Place of Origin | Mainland China |

4. Installation
4.1 Mounting the Controller
- Insert the controller into the prepared mounting hole.
- Slide the bracket to fix the device securely in place.

4.2 Wiring Diagram
Refer to the following diagram for proper wiring connections. Ensure all connections are secure and follow local electrical codes.

WARNING: Incorrect wiring can damage the device or cause electrical hazards. If you are unsure, consult a qualified electrician.
5. Operation
The ZL-7802D controller features a clear digital display and intuitive buttons for setting parameters. The display shows current temperature and humidity readings.
5.1 Temperature Control Modes
The controller supports two main temperature control modes:
- PID Control (U73=0): Provides precise temperature regulation. The output for the heater is managed by R5 and an external SSR.
- Hysteresis Control (U73=1): A simpler ON/OFF control method.
- When measured temperature > Set-point (SP) + U16, R5 and external SSR are de-energized (heater off).
- When measured temperature ≤ Set-point (SP) - U16, R5 and external SSR are 100% energized (heater on).

5.2 Egg Turning Functions (for Incubator Use)
- Egg Counter Zero: Resets the egg turning counter.
- Timed/Manual Egg Turning: Allows for automatic timed egg turning or manual initiation.
- Egg Turning Status Save At Power off: Retains the egg turning status even after a power interruption.
6. Alarms
The ZL-7802D includes alarm functions to alert users to critical temperature and humidity deviations.
6.1 Over/Under Temperature Alarm
- Over Temperature Alarm: When the measured temperature exceeds the high temperature alarm relative value (Set-point (SP) + U15), the display will show "tHi" blinking, R5 and the external SSR will de-energize, and the buzzer will sound.
- Under Temperature Alarm: When the measured temperature falls below the low temperature alarm relative value (Set-point (SP) - U14), the display will show "tLo" blinking, and the buzzer will sound.

6.2 Ultra High/Low Humidity Alarm
- Low Humidity Alarm: When the measured humidity is less than or equal to the low humidity alarm relative value (Set-humidity - U55), the display will show "hLo" blinking, and the buzzer will sound.
- High Humidity Alarm: When the measured humidity is greater than or equal to the high humidity alarm relative value (Set-humidity + U56), the display will show "hHi" blinking, and the buzzer will sound.

7. Maintenance
To ensure the longevity and accurate performance of your ZL-7802D controller, follow these maintenance guidelines:
- Cleaning: Regularly wipe the controller's surface with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Probe Care: Keep the temperature and humidity probes clean and free from dust or debris. Ensure they are not exposed to extreme physical stress.
- Environmental Conditions: Operate the controller within its specified environmental limits. Avoid areas with excessive moisture, dust, or corrosive gases.
- Wiring Inspection: Periodically check all wiring connections for looseness or damage. Tighten any loose connections and replace damaged wires immediately.
- Fuse Replacement: If the controller fails to power on, check and replace the fuse if necessary. Ensure the replacement fuse matches the original specifications (e.g., 3A 250V).
8. Troubleshooting
This section provides solutions to common issues you might encounter with your ZL-7802D controller.
| Problem | Possible Cause | Solution |
|---|---|---|
| Controller does not power on | No power supply; Blown fuse; Incorrect wiring | Check power connection; Replace fuse (3A 250V); Verify wiring against diagram. |
| Temperature/Humidity reading is inaccurate | Faulty sensor; Sensor not properly connected; Sensor placed in an unsuitable location | Check sensor connections; Ensure sensor is clean and unobstructed; Replace sensor if damaged. |
| Heater/Fan not activating | Incorrect set-point; Wiring issue to output device; Output device (heater/fan) malfunction | Verify temperature/humidity set-points and control mode; Check wiring for R1, R2, R3, R4, R5; Test heater/fan independently. |
| Alarm constantly active | Alarm set-points too close to operating range; Environmental conditions outside desired range | Adjust alarm parameters (U14, U15, U55, U56); Ensure operating environment is stable. |
9. User Tips
- For optimal performance in incubators, ensure the temperature and humidity probes are placed in a location that accurately reflects the conditions around the eggs, away from direct airflow or heat sources.
- When setting up for the first time, it's recommended to test the temperature and humidity control functions with a separate, calibrated thermometer/hygrometer to ensure accuracy.
- Familiarize yourself with the PID control parameters if you require very stable temperature control, as fine-tuning these can significantly improve performance.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.