LILYTECH ZL-7802D

Contents

ZL-7802D Temperature and Humidity Controller User Manual

Model: ZL-7802D | Brand: LILYTECH

1. Product Overview

The LILYTECH ZL-7802D is a versatile temperature and humidity controller designed for applications requiring precise environmental control, such as incubators and heating systems. It features PID temperature control, support for external SSR, and comprehensive alarm functions for both temperature and humidity.

ZL-7802D controller with chick and eggs, illustrating incubation, fledgling, and chick rearing periods.
ZL-7802D controller in an incubator setting, highlighting features like egg counter, timed/manual egg turning, and egg turning status save at power off.
ZL-7802D controller displaying temperature and humidity readings, with icons for various functions.
Front view of the ZL-7802D controller, showing its digital display for temperature (-40.0~99.9°C) and humidity (10.0~90.0%RH), along with indicators for external SSR support and PID temperature control.

2. Package Contents

Upon unpacking, please verify that all items listed below are present and in good condition:

  • 1 x ZL-7802D Temperature and Humidity Controller
  • 1 x NTC Temperature Probe
  • 1 x Humidity Probe
  • 1 x User Manual (this document)
  • 1 x Fuse
  • Necessary Wiring
Contents of the ZL-7802D package laid out on a white background.
The complete package contents, including the controller, probes, wiring, and fuse.

3. Specifications

FeatureSpecification
Model NumberZL-7802D
Product NameTemperature and Humidity Controller
Brand NameLILYTECH
TheoryTemperature Controller
TypeTemperature and humidity control
MaterialABS Plastic (Shell: PC + ABS flame retardant)
Power Supply100-240Vac, 50/60HZ
Setting Range-40.0~99.9°C, 10.0~90.0%RH
Temperature Sensing ElementNTC sensor, R=10KB-3470K
Built-in SSR Temperature Control Output (R5)5A, 250Vac (resistive load)
External SSR Temperature Control Output (Y+, Y-)4~20mA, 12Vdc
Protection ClassIP65 (Front Panel)
DimensionsW78 x H34.5 x D71 (mm)
Mounting HoleW71 x H29 (mm)
Weight256g (including packaging)
Battery IncludedNo
High-concerned chemicalNone
Place of OriginMainland China
Detailed view of the NTC Temperature Probe and Humidity Probe.
NTC Temperature Probe features high precision, waterproof, dustproof, and corrosion resistance with a range of -40.0 ~ 99.9°C. The Humidity Probe is small, offers stable performance, and has a range of 10.0-99.0%RH.

4. Installation

4.1 Mounting the Controller

  1. Insert the controller into the prepared mounting hole.
  2. Slide the bracket to fix the device securely in place.
Diagram showing two steps for installing the ZL-7802D controller into a panel and securing it with a bracket.
Installation steps: 1. Insert the controller into the hole. 2. Slide the bracket to fix the device.

4.2 Wiring Diagram

Refer to the following diagram for proper wiring connections. Ensure all connections are secure and follow local electrical codes.

Detailed wiring diagram for the ZL-7802D controller, showing connections for power, sensors, and outputs.
Wiring Diagram for ZL-7802D. Connections include: EX-SSR (Y+, Y-), Humi. Sensor, R1 (Fan), R2 (Humi.), R3 (Left-turning), R4 (Right-turning), R5 (Heater), Power Supply (N, L, 100-240Vac), and Fuse.

WARNING: Incorrect wiring can damage the device or cause electrical hazards. If you are unsure, consult a qualified electrician.

5. Operation

The ZL-7802D controller features a clear digital display and intuitive buttons for setting parameters. The display shows current temperature and humidity readings.

Product demonstration video showing the ZL-7802D controller and its components.

5.1 Temperature Control Modes

The controller supports two main temperature control modes:

  • PID Control (U73=0): Provides precise temperature regulation. The output for the heater is managed by R5 and an external SSR.
  • Hysteresis Control (U73=1): A simpler ON/OFF control method.
    • When measured temperature > Set-point (SP) + U16, R5 and external SSR are de-energized (heater off).
    • When measured temperature ≤ Set-point (SP) - U16, R5 and external SSR are 100% energized (heater on).
Diagram explaining PID and Hysteresis temperature control modes for the ZL-7802D.
Explanation of PID control (U73=0) and Hysteresis control (U73=1) for temperature regulation.

5.2 Egg Turning Functions (for Incubator Use)

  • Egg Counter Zero: Resets the egg turning counter.
  • Timed/Manual Egg Turning: Allows for automatic timed egg turning or manual initiation.
  • Egg Turning Status Save At Power off: Retains the egg turning status even after a power interruption.

6. Alarms

The ZL-7802D includes alarm functions to alert users to critical temperature and humidity deviations.

6.1 Over/Under Temperature Alarm

  • Over Temperature Alarm: When the measured temperature exceeds the high temperature alarm relative value (Set-point (SP) + U15), the display will show "tHi" blinking, R5 and the external SSR will de-energize, and the buzzer will sound.
  • Under Temperature Alarm: When the measured temperature falls below the low temperature alarm relative value (Set-point (SP) - U14), the display will show "tLo" blinking, and the buzzer will sound.
Diagram illustrating the conditions for over/under temperature alarms on the ZL-7802D controller.
Details on how the over/under temperature alarm functions, including display indicators and actions.

6.2 Ultra High/Low Humidity Alarm

  • Low Humidity Alarm: When the measured humidity is less than or equal to the low humidity alarm relative value (Set-humidity - U55), the display will show "hLo" blinking, and the buzzer will sound.
  • High Humidity Alarm: When the measured humidity is greater than or equal to the high humidity alarm relative value (Set-humidity + U56), the display will show "hHi" blinking, and the buzzer will sound.
Diagram illustrating the conditions for ultra high/low humidity alarms on the ZL-7802D controller.
Details on how the ultra high/low humidity alarm functions, including display indicators and actions.

7. Maintenance

To ensure the longevity and accurate performance of your ZL-7802D controller, follow these maintenance guidelines:

  • Cleaning: Regularly wipe the controller's surface with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Probe Care: Keep the temperature and humidity probes clean and free from dust or debris. Ensure they are not exposed to extreme physical stress.
  • Environmental Conditions: Operate the controller within its specified environmental limits. Avoid areas with excessive moisture, dust, or corrosive gases.
  • Wiring Inspection: Periodically check all wiring connections for looseness or damage. Tighten any loose connections and replace damaged wires immediately.
  • Fuse Replacement: If the controller fails to power on, check and replace the fuse if necessary. Ensure the replacement fuse matches the original specifications (e.g., 3A 250V).

8. Troubleshooting

This section provides solutions to common issues you might encounter with your ZL-7802D controller.

ProblemPossible CauseSolution
Controller does not power onNo power supply; Blown fuse; Incorrect wiringCheck power connection; Replace fuse (3A 250V); Verify wiring against diagram.
Temperature/Humidity reading is inaccurateFaulty sensor; Sensor not properly connected; Sensor placed in an unsuitable locationCheck sensor connections; Ensure sensor is clean and unobstructed; Replace sensor if damaged.
Heater/Fan not activatingIncorrect set-point; Wiring issue to output device; Output device (heater/fan) malfunctionVerify temperature/humidity set-points and control mode; Check wiring for R1, R2, R3, R4, R5; Test heater/fan independently.
Alarm constantly activeAlarm set-points too close to operating range; Environmental conditions outside desired rangeAdjust alarm parameters (U14, U15, U55, U56); Ensure operating environment is stable.

9. User Tips

  • For optimal performance in incubators, ensure the temperature and humidity probes are placed in a location that accurately reflects the conditions around the eggs, away from direct airflow or heat sources.
  • When setting up for the first time, it's recommended to test the temperature and humidity control functions with a separate, calibrated thermometer/hygrometer to ensure accuracy.
  • Familiarize yourself with the PID control parameters if you require very stable temperature control, as fine-tuning these can significantly improve performance.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.