1. Introduction
The Yieryi Smart Soil Sensor is a versatile device designed for comprehensive soil analysis. It measures five critical soil parameters: Nitrogen (N), Phosphorus (P), Potassium (K), Electrical Conductivity (EC), Soil Moisture, Temperature, and pH. With its user-friendly mobile application and durable design, it provides real-time data to help optimize plant growth and soil health in various agricultural and gardening settings.


2. Setup and Installation
2.1. App Download and Installation
- Scan the QR code below with your Android phone to download the application.
- Click on the normal download button to install the app.
- If your phone blocks the app installation, you may need to adjust security settings:
- Go to Settings → Security and privacy → Install unknown apps.
- Choose the app you use to download (e.g., Chrome or My Files).
- Turn on 'Allow from this source'.
- Then reopen the APK file to install.

2.2. Connecting the Sensor
- Ensure your Android phone has OTG (On-The-Go) functionality enabled.
- To enable OTG, go to your phone's Settings. Search for "OTG" and toggle the feature on. If you cannot find it, refer to your phone's manual or search online for specific instructions for your model.
- Note: OTG may automatically turn off after 10 minutes of inactivity on some devices.
- Connect the sensor's USB interface to your mobile phone using the provided OTG cable.
- Open the "Data Monitor" app.
- When the app interface displays data, it indicates the instrument is working properly and is ready for use.

3. Operation
3.1. Taking Measurements
- Select an appropriate measurement location, avoiding stones or hard objects.
- Ensure the steel needle is fully inserted into the soil during measurement.
- For accurate conductivity readings, the soil volumetric water content should be above approximately 20%. If the soil is too dry, add water and wait for it to fully penetrate before measuring.
- For long-term monitoring, measurements after irrigation or rainfall are recommended.
- When measuring on hard surfaces, drill a pilot hole (smaller than the probe diameter) before inserting the sensor.
- Avoid direct sunlight on the transmitter during measurement to prevent excessive temperature affecting readings. Use sunshade or protection when outdoors.
- It is recommended to take multiple measurements within a small area and use the average value for better accuracy.

3.2. App Interface and Data Management
The mobile app allows real-time viewing, storage, and export of soil data.


- View Data: Once connected, the app will display all parameter values on the main interface.
- Data Export: Click "Save Data" to export the current real-time data to an Excel file, which can be saved locally on your phone.
- Data Viewing: Navigate to the data viewing interface to review saved data, including names, recording times, and content.
- Parameter Modification: Access the parameter modification interface to adjust settings such as nitrogen, phosphorus, and potassium storage values, deviation values for each parameter, moisture mass and volume conversion coefficients, and temperature channels.
4. Maintenance
4.1. Cleaning the Probes
After each use, thoroughly clean the probes to ensure accurate future readings and prevent corrosion. One of the five probes, which is dark in color, is made of a special alloy and is prone to wear; ensure it is cleaned carefully.
4.2. Durability and Protection
The sensor has an IP68 waterproof and anti-corrosion rating, meaning it can be completely submerged in water or buried in soil for long-term dynamic detection. The probes are made of specially treated metal alloy materials, resistant to strong external impacts and not easily damaged.


5. Troubleshooting
- Q: Why is my app interface in Chinese?
- A: Please ensure you are using the newly upgraded English version of the app. If not, re-download using the provided QR code or contact customer service for the correct version.
- Q: The Nitrogen (N) reading is always 0.
- A: This often occurs when the soil is too dry. Add some water to the soil and allow it to soak in, then measure again for an accurate Nitrogen reading.
- Q: The app says “Connection failed” when I insert the sensor.
- A: This typically means OTG (On-The-Go) is not enabled on your phone. Most phones enable OTG automatically, but some require manual activation. Go to Settings → Other Settings → OTG and enable it. If you cannot find this option, search online for instructions specific to your phone model. Once enabled, reconnect the sensor.
- Q: The app can’t save my measurement data.
- A: Check if your phone's system has disabled the app's storage permission. Enable the app’s storage function in your phone's settings.
- Q: Can I use it with an iPhone?
- A: No, this device is currently compatible with Android and HarmonyOS systems only.
- Q: Can I test it in water?
- A: No, the sensor is designed for soil testing only. While it is waterproof (IP68), it should not be used to test water directly for parameter readings.
6. Specifications
| Parameter | Specification |
|---|---|
| DC Power Supply | DC5V |
| Maximum Power Consumption | 0.5W |
| Working Temperature | -40°C to +60°C |
| NPK Range | 0-1999mg/kg |
| Conductivity Range | 0-20000 µS/cm |
| Conductivity Resolution | 10 µS/cm |
| Conductivity Accuracy | ±3% FS (0-10000 µS/cm); ±5% FS (10000-20000 µS/cm) |
| Soil Moisture Range | 0-100% |
| Soil Moisture Resolution | 0.1% |
| Soil Moisture Accuracy | ±2% (0-50% @ brown soil, 30%, 25°C); ±3% (50-100% @ brown soil, 60%, 25°C) |
| Soil Temperature Range | -40°C to +80°C |
| Soil Temperature Resolution | 0.1°C |
| Soil Temperature Accuracy | ±0.5°C (at 25°C) |
| Soil pH Range | 3-9 PH |
| Soil pH Resolution | 0.1 pH |
| Protection Level | IP68 |
| Probe Material | Special metal alloy (Temp, humidity, conductivity, anti-corrosion) |
| Sealing Material | Black flame retardant epoxy resin |
| Default Cable Length | 1.5m (customizable) |
| Dimensions | 45 x 15 x 123mm |
| Output Signal | USB interface |

7. User Tips
- For accurate NPK readings, ensure the soil is adequately moist (above 20% volumetric water content). If the soil is dry, water it and wait for the water to penetrate before testing.
- Always clean the probes thoroughly after each use to prevent residue buildup and ensure consistent accuracy.
- When inserting the sensor, push it firmly and vertically into the soil without shaking to maintain the soil's original compactness around the probes.
- If you experience issues with the app, double-check your phone's OTG settings and app permissions (especially storage access).
8. Support
For further assistance or detailed information, please refer to the official user manual PDF available at: User Manual (PDF).
If you encounter any issues not covered in this manual, please contact the manufacturer's customer support.