Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Fangling F2500A and F2600 series CNC Plasma Flame Gantry Cutting Machine Controllers. These controllers are designed for precise 2-axis linkage control in industrial cutting applications, supporting both plasma and flame cutting processes. Please read this manual thoroughly before operating the equipment to ensure safe and efficient use.

Specifications

Feature Description
Control Axes 2-axis linkage
Control Accuracy ±0.001mm
Coordinate Range ± 99999.99mm
Max Pulse Frequency 200KHz
Max Operating Speed 15 m/min
Max Program Lines 80,000 lines
Max Single Program Size 4M
Time Resolution 10ms
System Power Supply DC 24V (power > 80W)
Operating Environment Temperature: -10°C to +60°C; Humidity: 0-95% non-condensing
Max Driving Motor Power (Arc Voltage Adjustment) 45W (up to 200W optional with T system)

Hardware Configuration

  • Display: 17-inch industrial VGA high-brightness LCD screen (for F2500A/F2600)
  • Memory: 64M SDRAM
  • User Program Space: 256M
  • Main Frequency: 400MHZ system main frequency
  • USB: USB1.1 interface (front panel), supports at least 16GB USB flash drive.
  • Keyboard: PCB film keyboard
  • Chassis: All-steel structure, completely shielded for anti-electromagnetic radiation, anti-interference, and anti-static.

System Interface

The controller features various interfaces for connectivity and control:

  • Motor Drive Interface: DB15 core male two-axis motor drive interface.
  • Output Interface: DB25-core female connector with 16 optically isolated outputs (max reverse current 300mA).
  • Input Interface: DB25-core male connector with 16 optically isolated inputs (max input current 300mA).
  • USB Interface: Front panel built-in USB1.1 interface for convenient transfer of cutting codes.
  • Serial Port: Optional standard DB9 core male serial port RS232 interface.
Back panel of the F2500A/F2600 controller showing Input, Output, Motor, and THC connections.
Figure 1: Back Panel Connections (Input, Output, Motor, THC)
Detailed view of the F2500A/F2600 back panel connections with safety warnings.
Figure 2: Detailed Back Panel with Connection Labels and Warnings

Interface Pinout Details

Table showing Input, Output, and Motor interface pin assignments and signal names.
Figure 3: Input, Output, and Motor Interface Pinout
Detailed pinout tables for 15-core PIN number, signal names, and remarks, along with physical dimensions of the controller.
Figure 4: Detailed Pinout Tables and Controller Dimensions

Setup and Installation

  1. Mounting: Refer to the physical dimensions provided in Figure 4 for proper panel cutout and mounting. Ensure adequate ventilation around the unit.
  2. Power Connection: Connect the DC 24V power supply to the designated terminals (DC 24V-24V+). Ensure the power supply is greater than 80W.
  3. Grounding: Ensure the system is firmly grounded to prevent electrical hazards and interference.
  4. Motor Connections: Connect the 2-axis motor drives to the DB15 core male interface. Refer to Figure 3 and Figure 4 for specific pin assignments (XDIR+, XDIR-, XCP+, XCP-, YDIR+, YDIR-, YCP+, YCP-).
  5. Input/Output Connections: Connect external control signals to the DB25-core male (inputs) and female (outputs) connectors as per the pinout diagrams in Figure 3 and Figure 4.
  6. THC Connections: Connect the Torch Height Controller (THC) to the dedicated THC terminals (THC4, THC5) on the back panel.
  7. RS232 (Optional): If using, connect the RS232 serial port to the DB9 core male interface.
  8. Initial Power-Up: Before powering on, double-check all connections. Do not open the unit without authorization, especially within 5 minutes after power-off due to residual charge.

Important Safety Warning: Do not open the unit without authorization. Installation and wiring should be performed by qualified personnel according to the provided manual. Ensure firm grounding. Wait at least 5 minutes after power-off before attempting to open the chassis to avoid electric shock.

Operation

The Fangling F2500A/F2600 controller offers a comprehensive set of features for precise cutting operations. The front panel includes a 17-inch LCD screen, a numerical keypad, and function buttons (F1-F8, Start, Stop, Prev, Next, PgUp, PgDn) for navigation and control.

Front panel of the F2500A/F2600 controller showing the graphical interface, keypad, and function buttons.
Figure 5: Controller Front Panel and User Interface
Close-up of the F2500A/F2600 controller screen displaying a cutting pattern and operational data.
Figure 6: Controller Screen Displaying Cutting Pattern

Key Operational Features:

  • Cutting Modes: Supports oxygen gas, plasma, powder spraying, and demonstration modes.
  • IO Control: Separate control for oxygen gas and plasma input/output.
  • Oxygen Gas Cutting: Features automatic height adjustment, two-stage preheating, and three-stage perforation for optimal results.
  • Plasma Cutting: Includes arc voltage feedback, positioning feedback, and automatic arc voltage adjustment. Supports dynamic perforation.
  • Edge Cutting: Utilize edge cutting functionality to reduce preheating time, especially for thicker steel plates.
  • Corner Speed Control: The system automatically limits speed at corners based on plate thickness to prevent overheating and improve cut quality.
  • Program Management:
    • Manually select the starting line or piercing point for cutting programs.
    • Dynamic/static processing graphics display allows for real-time visualization.
    • Graphics can be zoomed in/out, with dynamic tracking of cutting points in enlarged views.
    • The "Offset cutting" function helps avoid material waste due to nesting calculation errors.
    • Built-in graphic libraries (up to 48 standard graphics) can be called directly and parameters modified for fast cutting.
  • Data Transfer: Use the front panel USB interface to transfer cutting codes (G-code) from a USB flash drive.
  • Remote Control: Supports P2P mode or BCD (8421) and serial port RS232 for remote control.
  • Laser Pointing: Utilize the laser pointing function for precise alignment and setup.
  • Statistics: The system provides information statistics such as processing piece count, running time, and perforation times.
  • Security: Different management rights and corresponding passwords can be set to protect equipment settings.
Image showing plasma cutting in progress and a grid of 48 standard graphic libraries available on the controller.
Figure 7: Plasma Cutting in Action and Standard Graphic Libraries
Diagram illustrating the U disk upgrade method and a laser pointing module.
Figure 8: U Disk Upgrade Method and Laser Pointing Function

Maintenance

  • Software Updates: The system supports convenient U disk upgrade methods, providing lifetime upgrade service. Regularly check for and apply software updates to ensure optimal performance and access to new features.
  • Parameter Management: Utilize the parameter backup and restoration functions to safeguard your settings. It is recommended to back up critical parameters periodically.
  • Cleaning: Keep the controller's screen and keypad clean using a soft, dry cloth. Avoid using abrasive cleaners or solvents. Ensure ventilation openings are free from dust and debris.
  • Connection Checks: Periodically inspect all cable connections (power, motor, input/output, THC) to ensure they are secure and free from damage.
  • Environmental Conditions: Operate the controller within the specified temperature and humidity ranges to prolong its lifespan.

Troubleshooting

  • Power Issues: If the unit does not power on, verify the DC 24V power supply connection and ensure it meets the minimum power requirement (>80W). Check for any blown fuses in the power circuit.
  • System Freezes/Errors: If the system becomes unresponsive or displays an error, try restarting the controller. The power-off and breakpoint protection memory function can help recover from unexpected interruptions.
  • Cutting Inaccuracies: Check motor connections and ensure all parameters (e.g., plate thickness, cutting speed, offset) are correctly set. Verify that the gantry system itself is mechanically sound and calibrated.
  • Communication Problems: If experiencing issues with USB or RS232 communication, ensure cables are properly connected and drivers (if any) are installed correctly on the connected device.
  • Safety Warning Adherence: Always observe the safety warning to wait 5 minutes after power-off before opening the chassis to avoid electrical hazards.

User Tips

  • Regular Backups: Periodically back up your cutting programs and system parameters to a USB drive to prevent data loss.
  • Parameter Optimization: Experiment with different cutting parameters (speed, preheating time, arc voltage) for various materials and thicknesses to achieve the best cut quality.
  • Utilize Graphic Libraries: Take advantage of the built-in graphic libraries for common shapes to speed up program creation.
  • Keep Software Updated: Regularly update the controller's firmware via USB to benefit from performance improvements and new features.
  • Clean Environment: Maintain a clean working environment around the controller to prevent dust and debris from affecting its operation and lifespan.

Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model (F2500A or F2600) and any relevant serial numbers available when seeking support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.