FUZRR ES3080

Contents

FUZRR ES3080 Three-Channel DC Resistance Tester

Model: ES3080

User Manual

1. Introduction

The FUZRR ES3080 is a professional three-channel DC resistance tester designed for precise measurement of DC resistance in transformers and other electrical equipment. Featuring a 7-inch color touch screen with adjustable backlight, it offers intuitive operation and high accuracy. This manual provides essential information for the safe and effective use of your ES3080 tester.

FUZRR ES3080 DC Resistance Tester with the lid open, revealing the control panel and screen.
Figure 1: FUZRR ES3080 DC Resistance Tester (Open View)

2. Package Contents

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your supplier.

  • FUZRR ES3080 DC Resistance Tester Unit
  • Test Lead Set (Red, Blue, Yellow, Green - 5m each, two of each color)
  • 220V Power Cable
  • USB Cable
  • Instruction Manual
  • Warranty Certificate
  • CD (Software/Drivers)
  • Test Cord Bag
FUZRR ES3080 DC Resistance Tester and its included accessories: test leads, power cable, USB cable, instruction manual, warranty certificate, CD, and carrying bag.
Figure 2: Included Accessories

3. Specifications

Parameter Value
FunctionDC resistance measurement, transformer DC resistance measurement
DC Resistance Range0.0001mΩ~5000Ω
Accuracy±0.2%FS±5dgt
Minimum Resolution0.001mΩ
Output Current Display0.01mA~20.000A
Conversion ResistanceWinding material and measured temperature can be converted
Three-phase Unbalance RateAutomatically display the unbalance ratio of three-phase windings
Tap PositionManually settable in settings interface
Rated Measuring Power1000W
Power SupplyAC 220V 10A (50Hz)
BacklightAdjustable backlight brightness
Measurement MethodFour-wire test
Magnetic Aid TestHigh and low voltage output current, test resistance of low voltage terminal
Short Circuit Test Current0.2A, 0.5A, 2A, 5A, 10A, 20A (6 settings)
Maximum Short-Circuit CurrentDC 20A±10%
Maximum No-Load VoltageDC 27V±10%
Display Mode7 inch touch color screen
Touch ScreenYes
Measurement InstructionsMeasurement progress display, animation display
Meter Size (L×W×H)540mm×440mm×210mm
Standard Test Lead Length8 (total leads)
U Disk InterfaceSpecial interface for connecting U disk
USB InterfaceConnect to a computer with a USB cable to query and save data
PrinterBuilt-in thermal printer
Paper Specifications57*40mm
Data Storage500 groups
Data AccessYes
Overflow Display"OL" symbol display for overrange
Automatic Shut-downNone
Power Consumption (Standby)<110W
Power Consumption (Measurement)1000W
Gauge Weight27 kg
Accessories Weight5.5kg (Test lead, auxiliary ground rod, instrument bag)
Working Temperature & Humidity-10℃~40℃; below 80%rh
Storage Temperature & Humidity-20℃~60℃; below 70%rh
Insulation Resistance10MΩ or more (500V between circuit and case)
Pressure ResistanceAC 3700V/rms (between circuit and case)
Safety RegulationsIEC61010-1, IEC1010-2-31, IEC61557-1, 5, IEC60529 (IP54), pollution, etc. 2, CAT Ⅲ 300V
Infographic detailing key performance characteristics of the ES3080, including resistance range (0.0uΩ~5000Ω), resolution (0.1uΩ), short circuit current (20A), data storage (500 groups), USB interface, and touch screen operation.
Figure 3: Performance Characteristics Summary
Diagram showing the external dimensions of the FUZRR ES3080 DC Resistance Tester: 540mm length, 440mm width, 210mm height.
Figure 4: External Dimensions

4. Device Overview

The ES3080 features a robust design with clearly labeled interfaces for easy connection and operation.

Diagram illustrating the functional interfaces of the FUZRR ES3080 DC Resistance Tester, labeling ports for printer, power, voltage poles (Ua, Ub, Uc, Un), current poles (Ia, Ib, Ic, In), ground terminal, USB, and U-disk interface.
Figure 5: Functional Description of Interfaces
  1. Printer
  2. Power switch
  3. Ground terminal
  4. Ua interface: voltage pole
  5. Ia interface: current pole
  6. Ub interface: voltage pole
  7. Ib interface: current pole
  8. Uc interface: voltage electrode
  9. Ic interface: current pole
  10. Un interface: voltage pole
  11. In interface: current pole
  12. U-disk interface
  13. USB interface
Close-up of the FUZRR ES3080's 7-inch large color touch screen display with adjustable backlight brightness, showing measurement options.
Figure 6: 7-inch Touch Screen Display

5. Setup

5.1 Initial Inspection

Before use, inspect the tester and all accessories for any signs of damage. Ensure all connections are clean and secure.

5.2 Power Connection

  1. Ensure the power switch (2) on the device is in the OFF position.
  2. Connect the provided 220V power cable to the power input port on the device.
  3. Plug the other end of the power cable into a suitable AC 220V 10A (50Hz) power outlet.

5.3 Test Lead Connection (Four-Wire Test Method)

The ES3080 uses a four-wire test method for accurate resistance measurement. This involves separate current and voltage leads for each phase.

  1. Identify the voltage poles (Ua, Ub, Uc, Un) and current poles (Ia, Ib, Ic, In) on the device.
  2. Connect the appropriate test leads to their corresponding voltage and current pole interfaces. For example, connect one set of leads to Ua and Ia for phase A.
  3. Connect the other end of the test leads to the transformer windings or other equipment under test. Ensure proper polarity and secure connections.
  4. Connect the ground terminal (3) to a reliable ground point on the equipment or system being tested.
FUZRR ES3080 DC Resistance Tester connected to a transformer in a field application setting, demonstrating test lead connections.
Figure 7: Example of Field Application Connection to a Transformer

6. Operating Instructions

6.1 Power On/Off

  • To power on, flip the power switch (2) to the ON position. The 7-inch touch screen will illuminate.
  • To power off, flip the power switch (2) to the OFF position.

6.2 Basic Measurement Procedure

  1. After powering on, the main menu will appear on the touch screen.
  2. Select the desired measurement mode (e.g., "Three-phase Res", "Single phase Res", "Single line Res", "Null Line Res") by tapping the corresponding button on the screen.
  3. Access the "Parameter" menu to configure test settings such as short circuit test current (0.2A, 0.5A, 2A, 5A, 10A, 20A).
  4. Ensure the test leads are correctly connected to the equipment under test as described in Section 5.3.
  5. Initiate the measurement. The screen will display measurement progress and animation.
  6. Once the measurement is complete, the results will be displayed. The device can automatically display the unbalance ratio of three-phase windings.
  7. The winding material and measured temperature can be converted via the appropriate function on the device.

6.3 Data Management

  • Data Storage: The device can store up to 500 groups of measurement data. Use the "Data" menu on the touch screen to save results.
  • Data Access: Saved data can be accessed directly from the device via the "Data" menu.
  • USB/U-disk: Connect a U-disk to the U-disk interface (12) for external data storage or transfer. Use the USB interface (13) to connect the tester to a computer for data query and saving.
  • Printing: Utilize the built-in thermal printer (1) to print measurement results on 57*40mm paper.

7. Maintenance

  • Cleaning: Keep the device clean. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Storage: When not in use, store the ES3080 in its protective case in a dry environment within the specified storage temperature and humidity range (-20℃~60℃; below 70%rh).
  • Test Leads: Regularly inspect test leads for wear, cuts, or damage. Replace damaged leads immediately to ensure safety and accurate measurements.
  • Calibration: For continued accuracy, periodic calibration by qualified personnel is recommended.

8. Troubleshooting

  • Device does not power on:
    • Check if the power cable is securely connected to both the device and the power outlet.
    • Ensure the power outlet is functional and providing the correct voltage (AC 220V).
    • Verify the power switch is in the ON position.
  • No measurement reading or "OL" displayed:
    • Check if test leads are correctly and securely connected to both the device and the equipment under test.
    • Ensure the four-wire connection method is correctly implemented.
    • The "OL" symbol indicates an overrange condition; the measured resistance may be outside the device's range (0.0001mΩ~5000Ω).
    • Verify the equipment under test is properly prepared for measurement.
  • Inaccurate readings:
    • Ensure test leads are not damaged or corroded.
    • Check for external interference or unstable power supply.
    • Consider if the device requires calibration.
  • Touch screen unresponsive:
    • Try restarting the device.
    • Ensure the screen is clean and free from debris.

9. User Tips

  • Always ensure a stable power source for consistent measurement results.
  • When performing measurements in the field, double-check all connections to prevent errors and ensure safety.
  • Utilize the data storage and USB/U-disk functions regularly to back up important measurement data.
  • Adjust the backlight brightness of the 7-inch touch screen for optimal visibility in various lighting conditions.

10. Warranty and Support

The FUZRR ES3080 Three-Channel DC Resistance Tester comes with a 1-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For technical support, warranty claims, or service inquiries, please refer to the contact information provided with your purchase documentation or visit the official FUZRR website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.