1. Product Overview
The PowMr MPPT Solar Charge Controller is designed to efficiently manage power flow from your solar panels to your battery bank, ensuring optimal charging and system protection. It features Maximum Power Point Tracking (MPPT) technology for high efficiency and is compatible with 12V and 24V battery systems, including LiFePO4, Li-on, and Lead-Acid batteries.


2. Safety Information
- Ensure all wiring is correctly connected and secured to prevent short circuits.
- Always connect the battery first, then the solar panel, and finally the load. Disconnect in the reverse order.
- Do not attempt to repair or modify the controller yourself. Contact qualified personnel for service.
- Install the controller in a well-ventilated area, away from flammable materials and direct sunlight.

3. Setup and Installation
3.1 Wiring Connections
Follow the wiring diagram carefully. Connect the system in the following order:
- Connect the battery to the controller.
- Connect the DC load to the controller.
- Connect the PV array (solar panels) to the controller.
To disconnect the system, follow the reverse order: disconnect the PV array, then the load, and finally the battery.

3.2 Battery Type Selection
The controller is compatible with various battery types. To set the battery type:
- Long press the BAT/▲ key to enter the setting program.
- Use the BAT/▲ and DC/▼ keys to toggle through the battery type options.
- Press the SET/⚙ key to save and confirm your selection.
If you select a User-defined battery type, you can proceed with setting specific battery parameters.

4. Operating Instructions
4.1 LCD Display and Buttons
The controller features a backlight LCD screen that displays real-time system status, including PV input, battery voltage, and load status. The control panel includes four buttons for navigation and settings:
- PV: View PV array information.
- BAT/▲: View battery information and navigate up in settings.
- DC/▼: View DC load information and navigate down in settings.
- SET/⚙: Enter settings menu and confirm selections.

4.2 Working Modes
The controller operates in several working modes:
- 3.0: Night mode, no charging.
- 4.0: MPPT Charging Mode.
- 7.0: Boost Charging Mode.
- 8.0: Floating Charge Mode.
4.3 Load Work Modes
The load output can be configured with multiple work modes:
- 00H: Load is always OFF.
- 24H: Load is always ON.
- 01H~23H: Time control, where the load is ON for the specified duration (e.g., 01H for 1 hour, 23H for 23 hours).

5. Maintenance
- Regularly inspect all wiring connections for tightness and corrosion.
- Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
- Ensure proper ventilation around the controller to prevent overheating.
- Check battery terminals periodically for any signs of wear or damage.
6. Troubleshooting
The LCD screen displays error codes to help diagnose issues. Refer to the table below for common fault codes and their solutions:
| Fault Code | Fault Cause | Solution |
|---|---|---|
| 18 | Input photovoltaic voltage too low | Increase the number of solar panels or connect them in series to raise the photovoltaic input voltage. |
| 60 | Overtemperature protection | Allow the equipment to cool to below the recovery temperature to resume normal charging and discharging. |
| 63 | Battery voltage too high | Measure to confirm if battery voltage exceeds rated voltage and disconnect photovoltaic array circuit breaker. |
| 65 | Battery voltage too low | Charge the battery until voltage exceeds the undervoltage recovery point. Refer to '3.7 Default Parameters for Different Battery Types' for specific details. |
| 71 | Input photovoltaic voltage too high | Reduce the number of photovoltaic arrays connected to the controller to lower photovoltaic input; or adjust series and parallel connections to reduce voltage or current values. |
| 73 | Overcharging current | Reduce output terminal load to ensure total load is within rated limits of the controller and battery. |
| 72 | Overdischarging current | Reduce output terminal load to ensure total load is within rated limits of the controller and battery. |
7. Specifications
| Feature | POW-M25-PRO | POW-M35-PRO | POW-M45-PRO |
|---|---|---|---|
| System Voltage | 12V / 24V Auto | ||
| Max PV Open-Circuit Voltage | 60V | 80V | 100V |
| Max PV Input Power (12V System) | 300W | 420W | 540W |
| Max PV Input Power (24V System) | 600W | 840W | 1080W |
| Dimensions | 6.3" x 4.53" x 2.01" | 7.68" x 5.31" x 2.56" | |
| Net Weight | 1.1lb | 1.98lb | 2.28lb |
| Certification | CE, FCC, RoHS | ||
8. User Tips
- For optimal performance, ensure your solar panel array voltage is within the recommended range for your controller model.
- When using lithium batteries, ensure the activation function is properly configured if required by your battery type.
- Periodically check the ambient temperature around the controller, especially in enclosed spaces, to prevent overheating.
- Always refer to the detailed battery parameters in the full manual for specific settings for different battery types.
9. Warranty and Support
This PowMr MPPT Solar Charge Controller comes with a 12-month warranty. For technical support, troubleshooting assistance beyond the provided guide, or warranty claims, please contact PowMr customer service through their official channels.