1. Product Overview

The JIKONG V19 Smart BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It offers comprehensive features including voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and PC monitoring capabilities. This BMS is compatible with LiFePO4, Li-ion, and LTO battery types.

The protection board utilizes energy transfer active balancing technology, ensuring a maximum continuous 2A balance current. This high-current active equalization technology optimizes battery consistency, extends battery range, and delays battery aging.

A mobile APP (Android and iOS compatible) allows users to connect via Bluetooth to monitor battery status, modify parameters, and control charge/discharge switches. Its compact size, simple operation, and full functionality make it ideal for high-power energy storage, base station backup power, and solar power station battery packs.

2. Functional Characteristics

The JIKONG V19 Smart BMS offers a wide range of features to ensure optimal battery performance and safety:

  • LED Bluetooth status indicator
  • APP Bluetooth remote operation
  • Battery capacity calculation
  • Supports PC operations
  • High precision voltage acquisition (±3mV)
  • High precision current acquisition
  • Support information screen display
  • Accurate time logging
  • Support RS485 communication
  • Support CAN communication
  • Support heating function
  • Alarm dry contact function
  • Charge overcurrent protection
  • Charge overvoltage protection
  • Charge over temperature protection
  • Low temperature protection during charge
  • Discharge overcurrent protection
  • Discharge undervoltage protection
  • Discharge over temperature protection
  • Short circuit protection
  • Battery parallel current limiting function

3. Package Contents

The JIKONG V19 Smart BMS package includes the following items:

Video: Unboxing and overview of the JIKONG V19 Smart BMS and its components.
JIKONG V19 BMS Packing List showing all included components.
Image: Detailed view of the JIKONG V19 BMS packing list, including the BMS unit, interface board, adapter, RJ45 network cable, switch, heating adapter cable, B+ cable, sampling lines (A, B, C), adapter cables (A, B, C), and the 4.3-inch LCD display.
  1. Packing Box
  2. BMS Unit
  3. Interface Board
  4. Adapter
  5. RJ45 Network Cable (400mm)
  6. Switch (500mm)
  7. Heating Adapter Cable x1 (170mm)
  8. Cells Total B+ Cable x1 (500mm)
  9. Sampling Line A (900mm)
  10. Sampling Line B (900mm)
  11. Sampling Line C (900mm)
  12. Adapter Cable A (300mm)
  13. Adapter Cable B (300mm)
  14. Adapter Cable C (300mm)
  15. 4.3LCD-TTL-P Display (Optional, depending on model)

4. Setup and Installation

4.1. Interface Board Overview

The interface board facilitates connections for various functions including LED indicators, reset switch, DIP switch, dry contacts, and communication ports. The LED indicators help in determining the BMS's operational status and remaining battery power. The reset button can be used to reset the BMS in case of malfunction. The DIP switch is crucial for setting the address when multiple BMS units are used in parallel.

JIKONG V19 BMS Interface Board Diagram showing RS485-1, RS485-2, RS232, Dry Interface, Switch, P1, P2, P3, UART Port, Display/Switch Port, and Heat Function Port.
Image: Diagram of the JIKONG V19 BMS interface board, detailing the various ports and their functions.

4.2. Wiring Instructions

The JIKONG V19 BMS is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure all connections are secure and correct before powering on the BMS.

4.2.1. Wiring for 16-String Cells

Wiring diagram for a 16-string cell battery pack with the JIKONG V19 BMS. It shows connections for individual cells, total positive and negative electrodes, charger, and load.
Image: Wiring diagram illustrating how to connect a 16-string cell battery pack to the JIKONG V19 BMS, including connections for the charger and load.

4.2.2. Wiring for 8-String Cells

Wiring diagram for an 8-string cell battery pack with the JIKONG V19 BMS. It shows connections for individual cells, total positive and negative electrodes, charger, and load.
Image: Wiring diagram illustrating how to connect an 8-string cell battery pack to the JIKONG V19 BMS, including connections for the charger and load.

4.3. Device Activation

Before powering on the protection board, double-check that the balance wires are correctly connected and that the P- and B- terminals are properly connected. Ensure the protection board is securely fixed to the battery pack. Once confirmed, you can power on the BMS.

The BMS does not have a physical power-on switch. It is designed for charging activation mode. After the battery assembly is complete, connect the charger (with a voltage 2V higher than the battery voltage) to activate the BMS. Alternatively, if you have the optional display screen and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.

5. Operating Instructions

5.1. Mobile APP and PC Software

The JIKONG V19 BMS supports both a mobile APP (Android and iOS) and PC software for monitoring and control. These interfaces allow you to view real-time battery data, adjust protection parameters, and manage various functions.

Multi-screen display data connection showing mobile app, PC software, and home storage display interfaces for the JIKONG V19 BMS.
Image: Multi-screen display options for the JIKONG V19 BMS, including mobile APP, PC software, and a dedicated home storage display.

5.1.1. APP Installation

Scan the QR code below to download the mobile APP. Android Version 7 or higher is required.

QR code for JIKONG BMS mobile APP download.
Image: QR code to download the JIKONG BMS mobile application.

5.1.2. Parameter Setting via APP/PC

You can freely adjust multiple protection values such as overcharge, over-discharge, overcurrent, temperature, and balance. Before making changes, it is recommended to read the internal parameters of the protection board. The PC software provides a comprehensive interface for detailed parameter configuration.

PC software interface for JIKONG V19 BMS showing real-time status, parameter settings, BMS control, system log, detailed log, and 'About BMS' sections.
Image: PC software interface for intelligent interaction and easy operation, displaying various settings and monitoring options for the JIKONG V19 BMS.

5.2. Active Equalization (Lossless Balancing)

The BMS employs active equalization to transfer energy from higher-voltage cells to lower-voltage cells, ensuring minimal energy loss. This process maintains battery consistency, improves range, and extends battery life. The default balance current is 2A. Users can adjust the balance current based on battery capacity, ensuring it does not exceed 0.2C of the battery capacity. If balancing is not required, it can be switched off in the APP's BMS control page.

Active Balancing diagram showing energy transfer between cells and a wiring diagram for a battery pack with the JIKONG BMS.
Image: Diagram explaining Active Balancing (Lossless Balancing) and its principle of energy transfer between battery cells, along with a basic wiring illustration.

5.3. Heating Function

The BMS includes a heating function to warm the battery in low-temperature conditions using a resistance heater or heating film. This prevents performance degradation due to reduced battery activity. The designed heating current is 10A. Users can control this function via the APP's BMS control page. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary safety measure.5.4. Dry Contact Function

Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects over-temperature, overcharge, or over-discharge, the alarm interface can trigger a buzzer or activate a fan. Users can select two trigger conditions and configure them as needed.5.5. Communication Functions (CAN, RS485)

The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand. Two RS485 interfaces are available: RS485-1 for communication with inverters and other settings, and RS485-2 for parallel connection of battery packs and communication with a host computer. The default baud rate for RS485-2 is 115200. The communication address can be set using the DIP switch (0-15).

Mobile app screenshot showing selection of UART protocols for inverter communication, including various CAN and Modbus protocols.
Image: Mobile app interface for selecting UART protocols, compatible with mainstream inverter communication protocols.
PC software interface showing supported CAN protocols and settings for inverter communication.
Image: PC software interface for setting inverter communication protocols, including various CAN protocols.

5.6. Parallel Function

The parallel function allows simultaneous monitoring of multiple BMS units via a host computer using the RS485 bus. This requires a USB to RS485 serial port cable and the JIKONG host computer software. Up to 16 BMS units can be connected, with addresses from 0 to 15. BMS with address 0 acts as the host, and 1-15 as slaves. Addresses are set via DIP switches.

Diagram showing multiple JIKONG BMS units connected in parallel for monitoring by a host computer, with DIP switch settings for addressing.
Image: Schematic diagram illustrating how multiple JIKONG BMS units can be connected in parallel for centralized monitoring.

6. Protection Features

The JIKONG V19 BMS integrates several protection mechanisms to safeguard your battery system:

  • Overcharge Protection & Recovery: Prevents battery overcharging by shutting off charging when any cell exceeds the set overcharge voltage. Charging resumes when all cells drop below the recovery voltage.
  • Over-discharge Protection & Recovery: Prevents battery over-discharging by shutting off discharge when any cell drops below the set under-voltage protection value. Discharge resumes when all cells are above the recovery voltage. An automatic shutdown voltage also protects the battery.
  • Charge Overcurrent Protection & Recovery: Shuts off charging if the charging current exceeds the set continuous charging current for a specified delay. Charging resumes after the overcurrent release time.
  • Discharge Overcurrent Protection & Recovery: Shuts off discharge if the discharge current exceeds the set continuous discharge current for a specified delay. Discharge resumes after the overcurrent release time.
  • Over-temperature Protection & Recovery: Shuts off charging/discharging if the battery temperature exceeds the set over-temperature protection value. Operation resumes when the temperature drops below the recovery value.
  • Low-temperature Protection & Recovery: Shuts off charging if the battery temperature drops below the set low-temperature protection value. Charging resumes when the temperature rises above the recovery value.
  • Short Circuit Protection & Recovery: Automatically protects against short circuits. Users can adjust the short circuit protection delay and recovery time via the APP.
  • Emergency Switch: Provides a 30-minute window for emergency operation (both charge and discharge) even if protection conditions are met, to prevent critical failures.
  • Intelligent Sleep: Reduces BMS power consumption by entering a sleep mode when the battery is in standby (charging/discharging current less than 1A for 26 consecutive hours). It can be reactivated by button or charger.
  • Charge Current Limiting: Limits the charging current to approximately 10A if an overcurrent condition occurs during charging, protecting the battery.

7. Specifications

7.1. General Parameters

ParameterValueUnit
Supply Voltage20-70V
Standby Power Consumption12mW
Operating Power Consumption1100mW
Operating Temperature-30 to 70°C
Max. Number of Collection Strings16Strings
Max. Balancing Current2A
Max. Charging Current300A
Max. Discharge Current300A
Max. Instantaneous Current600A
Max. Internal Loop Resistance0.25mΩ
Protective Plate Size300x100x24mm
Finished Weight1000g
Product Parameters table for JIKONG BMS models, including number of battery strings, balance method, current ratings, and protection functions.
Image: Detailed product parameters table for various JIKONG BMS models, including specifications for Li-ion, LiFePO4, and LTO batteries.

7.2. Default Parameters

The following table outlines the default parameters for different battery chemistries. These can be adjusted via the APP or PC software.

ParameterLi-ion (Default)LiFePO4 (Default)LTO (Default)Unit
Balancing Initial Voltage332V
Maximum Balancing Current222A
Unit Overcharge Voltage4.23.62.7V
Single Overcharge Protection Recovery4.173.542.64V
Monomer Undervoltage Protection2.822.61.8V
Single Undervoltage Protection Recovery2.852.651.85V
Automatic Shutdown Voltage2.82.51.7V
SOC-0% Voltage2.92.61.85V
SOC-100% Voltage4.183.52.65V
Trigger Balancing Differential Pressure0.010.010.01V
Charging Overcurrent Protection Delay333S
Charging Overcurrent Protection Release Time606060S
Discharge Overcurrent Protection Delay300300300S
Discharge Overcurrent Protection Release Time606060S
Short-circuit Protection Delay555µS
Charging Overtemperature Protection707070°C
Charging Overtemperature Restore Temperature606060°C
Discharge Overtemperature Protection707070°C
Discharge Overtemperature Recovery Temperature606060°C
Charging Low Temperature Protection-20-20-20°C
Charging Low Temperature Restore Temperature-10-10-10°C
MOS Overtemperature Protection100100100°C
MOS Overtemperature Recovery808080°C
Device Address000/

8. Troubleshooting

If you encounter issues with your JIKONG V19 Smart BMS, consider the following troubleshooting steps:

  • BMS Not Activating: Ensure all balance wires, P- and B- connections are correct and secure. The BMS activates upon connecting a charger (voltage 2V higher than battery) or by pressing the button on the optional display.
  • Short Circuit Protection Triggered: If short circuit protection is triggered during charging (especially with a new charger) or discharge (with a new load), the peak current might be too high. Try increasing the 'Short Circuit Protection Delay' parameter in the APP/PC software. Verify external wiring for actual short circuits.
  • Monitoring Issues: If the mobile APP or PC software cannot connect or display data, ensure Bluetooth is enabled and the BMS is powered on. For parallel systems, verify DIP switch addresses and RS485 connections.
  • Temperature-related Issues: If the BMS is shutting down due to temperature, check the set over-temperature and low-temperature protection values in the APP/PC software. For cold environments, ensure the heating function is enabled and consider installing a temperature control switch.
  • Unexpected Shutdowns: Review the 'System Log' and 'Detailed Log' sections in the PC software for error messages or protection triggers. The emergency switch can provide temporary operation if needed.

9. User Tips

  • Verify Version: Always confirm that you are using the correct V19 version of the BMS and corresponding software/firmware for optimal compatibility and performance.
  • Initial Setup Check: Before first use, meticulously check all wiring connections (Bat+, B-, balance wires) and ensure the BMS is securely mounted. Proper activation is key.
  • Customizing Parameters: The BMS offers extensive customization. Familiarize yourself with the default parameters and adjust them via the mobile APP or PC software to match your specific battery capacity and usage requirements.
  • Balancing Function: If active balancing is not required for your application, you can disable it in the BMS control page of the APP to potentially reduce power consumption.
  • Cold Weather Operation: For installations in extremely cold regions, it is highly recommended to utilize the heating function to protect battery cells and maintain efficiency. Consider adding an external temperature control switch for enhanced safety.
  • Parallel System Addressing: When setting up multiple BMS units in parallel, carefully configure the unique address for each unit using the DIP switches to ensure proper communication and monitoring.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official user manual PDF available for download. This document contains comprehensive guides and additional information.

Reference: JIKONG V19 BMS User Manual (PDF)


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.