1. Product Overview
The JIKONG V19 Smart BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It offers comprehensive features including voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and PC monitoring capabilities. This BMS is compatible with LiFePO4, Li-ion, and LTO battery types.
The protection board utilizes energy transfer active balancing technology, ensuring a maximum continuous 2A balance current. This high-current active equalization technology optimizes battery consistency, extends battery range, and delays battery aging.
A mobile APP (Android and iOS compatible) allows users to connect via Bluetooth to monitor battery status, modify parameters, and control charge/discharge switches. Its compact size, simple operation, and full functionality make it ideal for high-power energy storage, base station backup power, and solar power station battery packs.
2. Functional Characteristics
The JIKONG V19 Smart BMS offers a wide range of features to ensure optimal battery performance and safety:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- Supports PC operations
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 communication
- Support CAN communication
- Support heating function
- Alarm dry contact function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Battery parallel current limiting function
3. Package Contents
The JIKONG V19 Smart BMS package includes the following items:

- Packing Box
- BMS Unit
- Interface Board
- Adapter
- RJ45 Network Cable (400mm)
- Switch (500mm)
- Heating Adapter Cable x1 (170mm)
- Cells Total B+ Cable x1 (500mm)
- Sampling Line A (900mm)
- Sampling Line B (900mm)
- Sampling Line C (900mm)
- Adapter Cable A (300mm)
- Adapter Cable B (300mm)
- Adapter Cable C (300mm)
- 4.3LCD-TTL-P Display (Optional, depending on model)
4. Setup and Installation
4.1. Interface Board Overview
The interface board facilitates connections for various functions including LED indicators, reset switch, DIP switch, dry contacts, and communication ports. The LED indicators help in determining the BMS's operational status and remaining battery power. The reset button can be used to reset the BMS in case of malfunction. The DIP switch is crucial for setting the address when multiple BMS units are used in parallel.

4.2. Wiring Instructions
The JIKONG V19 BMS is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure all connections are secure and correct before powering on the BMS.
4.2.1. Wiring for 16-String Cells

4.2.2. Wiring for 8-String Cells

4.3. Device Activation
Before powering on the protection board, double-check that the balance wires are correctly connected and that the P- and B- terminals are properly connected. Ensure the protection board is securely fixed to the battery pack. Once confirmed, you can power on the BMS.
The BMS does not have a physical power-on switch. It is designed for charging activation mode. After the battery assembly is complete, connect the charger (with a voltage 2V higher than the battery voltage) to activate the BMS. Alternatively, if you have the optional display screen and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.
5. Operating Instructions
5.1. Mobile APP and PC Software
The JIKONG V19 BMS supports both a mobile APP (Android and iOS) and PC software for monitoring and control. These interfaces allow you to view real-time battery data, adjust protection parameters, and manage various functions.

5.1.1. APP Installation
Scan the QR code below to download the mobile APP. Android Version 7 or higher is required.

5.1.2. Parameter Setting via APP/PC
You can freely adjust multiple protection values such as overcharge, over-discharge, overcurrent, temperature, and balance. Before making changes, it is recommended to read the internal parameters of the protection board. The PC software provides a comprehensive interface for detailed parameter configuration.

5.2. Active Equalization (Lossless Balancing)
The BMS employs active equalization to transfer energy from higher-voltage cells to lower-voltage cells, ensuring minimal energy loss. This process maintains battery consistency, improves range, and extends battery life. The default balance current is 2A. Users can adjust the balance current based on battery capacity, ensuring it does not exceed 0.2C of the battery capacity. If balancing is not required, it can be switched off in the APP's BMS control page.

5.3. Heating Function
The BMS includes a heating function to warm the battery in low-temperature conditions using a resistance heater or heating film. This prevents performance degradation due to reduced battery activity. The designed heating current is 10A. Users can control this function via the APP's BMS control page. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary safety measure.5.4. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects over-temperature, overcharge, or over-discharge, the alarm interface can trigger a buzzer or activate a fan. Users can select two trigger conditions and configure them as needed.5.5. Communication Functions (CAN, RS485)
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand. Two RS485 interfaces are available: RS485-1 for communication with inverters and other settings, and RS485-2 for parallel connection of battery packs and communication with a host computer. The default baud rate for RS485-2 is 115200. The communication address can be set using the DIP switch (0-15).


5.6. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units via a host computer using the RS485 bus. This requires a USB to RS485 serial port cable and the JIKONG host computer software. Up to 16 BMS units can be connected, with addresses from 0 to 15. BMS with address 0 acts as the host, and 1-15 as slaves. Addresses are set via DIP switches.

6. Protection Features
The JIKONG V19 BMS integrates several protection mechanisms to safeguard your battery system:
- Overcharge Protection & Recovery: Prevents battery overcharging by shutting off charging when any cell exceeds the set overcharge voltage. Charging resumes when all cells drop below the recovery voltage.
- Over-discharge Protection & Recovery: Prevents battery over-discharging by shutting off discharge when any cell drops below the set under-voltage protection value. Discharge resumes when all cells are above the recovery voltage. An automatic shutdown voltage also protects the battery.
- Charge Overcurrent Protection & Recovery: Shuts off charging if the charging current exceeds the set continuous charging current for a specified delay. Charging resumes after the overcurrent release time.
- Discharge Overcurrent Protection & Recovery: Shuts off discharge if the discharge current exceeds the set continuous discharge current for a specified delay. Discharge resumes after the overcurrent release time.
- Over-temperature Protection & Recovery: Shuts off charging/discharging if the battery temperature exceeds the set over-temperature protection value. Operation resumes when the temperature drops below the recovery value.
- Low-temperature Protection & Recovery: Shuts off charging if the battery temperature drops below the set low-temperature protection value. Charging resumes when the temperature rises above the recovery value.
- Short Circuit Protection & Recovery: Automatically protects against short circuits. Users can adjust the short circuit protection delay and recovery time via the APP.
- Emergency Switch: Provides a 30-minute window for emergency operation (both charge and discharge) even if protection conditions are met, to prevent critical failures.
- Intelligent Sleep: Reduces BMS power consumption by entering a sleep mode when the battery is in standby (charging/discharging current less than 1A for 26 consecutive hours). It can be reactivated by button or charger.
- Charge Current Limiting: Limits the charging current to approximately 10A if an overcurrent condition occurs during charging, protecting the battery.
7. Specifications
7.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Collection Strings | 16 | Strings |
| Max. Balancing Current | 2 | A |
| Max. Charging Current | 300 | A |
| Max. Discharge Current | 300 | A |
| Max. Instantaneous Current | 600 | A |
| Max. Internal Loop Resistance | 0.25 | mΩ |
| Protective Plate Size | 300x100x24 | mm |
| Finished Weight | 1000 | g |

7.2. Default Parameters
The following table outlines the default parameters for different battery chemistries. These can be adjusted via the APP or PC software.
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 2 | 2 | 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.17 | 3.54 | 2.64 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 3 | 3 | 3 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | µS |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charging Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charging Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
8. Troubleshooting
If you encounter issues with your JIKONG V19 Smart BMS, consider the following troubleshooting steps:
- BMS Not Activating: Ensure all balance wires, P- and B- connections are correct and secure. The BMS activates upon connecting a charger (voltage 2V higher than battery) or by pressing the button on the optional display.
- Short Circuit Protection Triggered: If short circuit protection is triggered during charging (especially with a new charger) or discharge (with a new load), the peak current might be too high. Try increasing the 'Short Circuit Protection Delay' parameter in the APP/PC software. Verify external wiring for actual short circuits.
- Monitoring Issues: If the mobile APP or PC software cannot connect or display data, ensure Bluetooth is enabled and the BMS is powered on. For parallel systems, verify DIP switch addresses and RS485 connections.
- Temperature-related Issues: If the BMS is shutting down due to temperature, check the set over-temperature and low-temperature protection values in the APP/PC software. For cold environments, ensure the heating function is enabled and consider installing a temperature control switch.
- Unexpected Shutdowns: Review the 'System Log' and 'Detailed Log' sections in the PC software for error messages or protection triggers. The emergency switch can provide temporary operation if needed.
9. User Tips
- Verify Version: Always confirm that you are using the correct V19 version of the BMS and corresponding software/firmware for optimal compatibility and performance.
- Initial Setup Check: Before first use, meticulously check all wiring connections (Bat+, B-, balance wires) and ensure the BMS is securely mounted. Proper activation is key.
- Customizing Parameters: The BMS offers extensive customization. Familiarize yourself with the default parameters and adjust them via the mobile APP or PC software to match your specific battery capacity and usage requirements.
- Balancing Function: If active balancing is not required for your application, you can disable it in the BMS control page of the APP to potentially reduce power consumption.
- Cold Weather Operation: For installations in extremely cold regions, it is highly recommended to utilize the heating function to protect battery cells and maintain efficiency. Consider adding an external temperature control switch for enhanced safety.
- Parallel System Addressing: When setting up multiple BMS units in parallel, carefully configure the unique address for each unit using the DIP switches to ensure proper communication and monitoring.
10. Warranty and Support
For detailed warranty information and technical support, please refer to the official user manual PDF available for download. This document contains comprehensive guides and additional information.
Reference: JIKONG V19 BMS User Manual (PDF)