1. Introduction
The ASAIR AGP11 Series Piezoresistive Vacuum Gauge is a high-precision instrument designed for accurate vacuum measurement. Utilizing advanced piezoresistive technology, it offers exceptional corrosion resistance, high precision, and long-term stability, making it suitable for a wide range of industrial and scientific applications. This manual provides essential information for the safe and effective installation, operation, and maintenance of your AGP11 vacuum gauge.

2. Safety Information
Please read and understand all safety instructions before installing, operating, or maintaining the AGP11 vacuum gauge. Failure to follow these instructions may result in personal injury or damage to the equipment.
- Installation should only be performed by qualified personnel familiar with vacuum systems and electrical wiring.
- Ensure the power supply voltage matches the specifications of the device (24V DC).
- Do not exceed the specified operating temperature and pressure ranges.
- Always disconnect power before performing any wiring or maintenance.
- Handle the vacuum gauge with care to avoid damage to the sensor or connections.
- Ensure proper grounding to prevent electrical hazards.
3. Product Overview
The AGP11 series vacuum gauge is designed for robust performance in demanding environments. Key features include:
- High Precision: Accuracy of ±0.5% FS (Full Scale).
- Wide Measurement Range: Available in 0-100 Torr and 0-1000 Torr variants.
- Multiple Output Options: Supports 4-20mA, 0-10V, and 1-5V analog output signals.
- Gas Type Independence: Measurement is not affected by the type of gas.
- Corrosion Resistance: Constructed with 316L stainless steel and ceramic materials exposed to vacuum.
- Optional Digital Display: Some models feature an integrated digital display for local reading.
- Standardized Connection: Equipped with a KF16 flange for easy integration into vacuum systems.
Typical Applications:
- Semiconductor manufacturing
- Vacuum coating processes
- Solar energy production
- Metallurgy and material science
- Petrochemical industry
- Medical equipment
- Aerospace research
- Scientific research and development
- Environmental protection systems
4. Specifications
The following table details the technical specifications for the ASAIR AGP11 Series Piezoresistive Vacuum Gauge:

| Parameter | Specification |
|---|---|
| Model | AGP11 Series |
| Measurement Range | 0-100 Torr, 0-1000 Torr |
| Accuracy | ±0.5% FS |
| Output Signal | 4-20mA, 0-10V, 1-5V (model dependent) |
| Power Supply | 24V DC |
| Process Connection | KF16 (standard), KF25, KF40, 1/4" NPT, 1/2" NPT, 1/8" NPT, 1/4" VCR, 1/2" VCR, 1/4" Swagelok, 1/2" Swagelok (various options available) |
| Materials Exposed to Vacuum | 316L Stainless Steel, Ceramic |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 70°C |
| Weight | Approx. 0.5 kg (depending on configuration) |
For detailed dimensions, please refer to the diagrams in Figure 2.
5. Setup and Installation
Proper installation is crucial for the accurate and reliable operation of the AGP11 vacuum gauge.
5.1 Mechanical Installation
- The AGP11 series features a standardized KF16 flange connection for easy integration. Ensure the mating flange on your vacuum system is clean and free of debris.
- Use appropriate O-rings and clamps to create a leak-tight seal.
- Mount the gauge in a position that minimizes vibration and is easily accessible for wiring and observation.
- Avoid mounting the gauge directly above sources of heat or in areas with extreme temperature fluctuations.
5.2 Electrical Wiring
The AGP11 gauge requires a 24V DC power supply. Refer to the wiring diagrams below and the pin definitions for correct connection. Always ensure power is disconnected before wiring.

| Pin No. | Function |
|---|---|
| 1 | Power+ (24V DC) |
| 2 | Power- (GND) |
| 3 | Signal+ (Current/Voltage Output) |
| 4 | Signal- (Current/Voltage Output) |
Connect the plug to the corresponding socket and tighten the screw securely. Ensure all connections are firm and correctly polarized.
6. Operation
Once installed and wired correctly, the AGP11 vacuum gauge is ready for operation.
- Power On: Apply 24V DC power to the gauge.
- Reading Display (if applicable): For models with a digital display, the current vacuum pressure will be shown on the LED screen. The display typically shows the pressure in Torr.
- Analog Output: The gauge will continuously provide an analog output signal (4-20mA, 0-10V, or 1-5V) corresponding to the measured vacuum pressure. This signal can be connected to a PLC, data acquisition system, or other control devices.
- Display Controls (if applicable): Models with a display may have 'up' and 'down' buttons for adjusting display settings or viewing different parameters. Consult the specific model's detailed instructions for advanced display functions.

7. Maintenance
The AGP11 vacuum gauge is designed for low maintenance due to its robust construction and corrosion-resistant materials. However, regular checks can ensure optimal performance and longevity.
- Cleaning: Periodically inspect the vacuum connection port for any contamination. If cleaning is necessary, use appropriate vacuum-compatible cleaning agents and procedures. Avoid harsh chemicals or abrasive materials that could damage the sensor or sealing surfaces.
- Connection Integrity: Regularly check all electrical and vacuum connections for tightness and signs of wear. Loose connections can lead to inaccurate readings or system leaks.
- Calibration: While the AGP11 offers high stability, periodic calibration by a qualified technician using a certified reference standard is recommended to maintain measurement accuracy over time, especially in critical applications.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent premature aging or malfunction.
8. Troubleshooting
This section provides guidance for common issues encountered with the AGP11 vacuum gauge. For problems not listed here, please contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/No output | No power or incorrect wiring | Check 24V DC power supply and verify wiring according to Section 5.2. |
| Inaccurate readings | Contamination, leak in vacuum system, or gauge malfunction | Check for leaks in the vacuum system. Inspect gauge for contamination. Consider professional calibration if issues persist. |
| Fluctuating readings | System instability, electrical noise, or vibration | Ensure stable vacuum conditions. Check for sources of electrical noise or excessive vibration near the gauge. |
| Gauge not responding to pressure changes | Sensor damage or internal fault | Contact technical support for diagnosis and potential repair or replacement. |
9. User Tips
- The AGP11's measurement is not affected by gas type, simplifying its use across various applications without needing gas-specific calibration factors.
- Its compact and robust design facilitates easy installation and convenient disassembly, contributing to reduced maintenance efforts.
- Consider the "screenless" models for applications where local visual indication is not required, relying solely on the analog output for system integration.
- For critical applications, leverage the multiple output options (4-20mA, 0-10V, 1-5V) to integrate seamlessly with your existing control systems.
10. Warranty and Support
ASAIR (Guangzhou Aosong Electronic Co., Ltd.) is committed to providing high-quality products and excellent customer service.
- Warranty: The AGP11 Series Piezoresistive Vacuum Gauge comes with a 1-year product warranty from the date of purchase.
- Technical Support: For any technical inquiries, installation assistance, or troubleshooting guidance, please contact ASAIR's official support team.
- Quality Assurance: Product quality certificates are available upon request.
- Customization: Customized services, including cable length, PCB changes, OEM, and ODM, are available. Please contact support for details.
Contact Information:
For support, please email: support@aosong.com