1. Introduction and Overview
The SUMRY EP4200-H is an advanced all-in-one solar inverter charger designed for efficient power management in various applications. It integrates an MPPT charge controller, battery charger, and power inverter into a single unit, offering dual voltage output capabilities (2.3KW for 12VDC systems and 4.2KW for 24VDC systems).
This inverter features a 100A MPPT solar charge controller and a 100A battery charger, with a PV input range of 55-500VDC and a maximum PV array power of 4000W. The output is a stable 230VAC at 50/60Hz, making it compatible with a wide range of electrical appliances. It is battery adaptive, supporting 12V and 24V battery systems, including GEL, LI (Lithium), AGM, USER-defined, and FLD (Flooded) types.

2. Safety Information
Please read and understand all safety instructions before installation and operation to prevent injury and damage to the unit. Keep this manual for future reference.
General Safety Precautions:
- All wiring and installation procedures must be performed by qualified personnel in accordance with local electrical codes and regulations.
- Ensure proper grounding of the inverter.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure adequate ventilation around the inverter to prevent overheating.
Integrated Safety Protections:
The SUMRY EP4200-H is equipped with comprehensive safety features to ensure reliable and stable operation:
- Overload Protection: Prevents damage from excessive load.
- Overheating Protection: Shuts down the unit if internal temperature exceeds safe limits.
- Short Circuit Protection: Protects against short circuits in the output.
- Overcurrent Protection: Safeguards against excessive current draw.
- Battery Protection: Includes safeguards against overcharge and over-discharge.
- High/Low Voltage Protection: Protects the system from abnormal voltage levels.

3. Product Features
The SUMRY EP4200-H offers a range of features for optimal solar power utilization:
- Pure Sine Wave Output: Provides commercial-grade, high-quality AC power, compatible with over 98% of electrical appliances, ensuring efficient and stable operation.
- Dual Voltage Compatibility: Works with both 12VDC and 24VDC battery systems. Rated power is 2300W when operating with a 12VDC battery and 4200W with a 24VDC battery.
- Advanced MPPT Technology: Built-in MPPT charge controller with an operating voltage range of 55V to 500V and an open circuit voltage of 500VDC, maximizing solar energy harvest.
- Real-Time Monitoring: Features a clear LCD display for effortless real-time monitoring of system status. An optional WiFi module allows for remote monitoring and control via the Sun house App.
- Hybrid Functionality: Supports three charging modes (Solar First, Solar and Utility, Only Solar) and three output modes (SUB, SBU, MKS), making it suitable for various hybrid solar scenarios.
- Battery Type Adaptability: Compatible with multiple battery types including GEL, Lithium (LI), AGM, USER-defined, and Flooded (FLD) batteries.
- Communication Ports: Includes an RS485 port for communication with Battery Management Systems (BMS) and an RS232 communication port.
- Dustproof Design: Features a built-in anti-dust kit and a dustproof construction for enhanced durability.


4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your SUMRY solar inverter. Always ensure all connections are secure and follow local electrical codes.
4.1 Product Appearance and Connections


- LCD screen
- Status indicator
- Charging indicator
- Fault indicator
- Function keys (ESC, UP, DOWN, ENTER)
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- Circuit breaker
- Ground wire terminal
- BMS communication port
- RS232 communication port
4.2 PV Connection
CAUTION: Before connecting the PV module, please install a separate DC circuit breaker between the inverter and the PV module.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It is very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size.
PV Module Selection:
When selecting proper PV modules, consider the following parameters:
- Open circuit Voltage (Voc) of PV modules should not exceed the maximum PV array open circuit voltage of the inverter (500VDC).
- Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
| Model | Wire Gauge | Torque Value |
|---|---|---|
| 12V/24V | 1 * 16 AWG | 1.2-1.6 Nm |
| Parameter | Value |
|---|---|
| Max. PV Array Power | 4000W |
| I Max. PV | 18A |
| Nominal PV Voltage | 240V |
| PV Array MPPT Voltage Range | 55-500V |
| Max. PV Array Open Circuit Voltage | 500V |
Example configuration for 250Wp PV module:
| Solar panel parameters -250Wp | Range (Min in serial: 6 pcs, max in serial: 11 pcs) | Q'ty of panels | Total Input |
|---|---|---|---|
| -Vmp: 30.1Vdc | 3 pcs in serial | 3 | 750W |
| -Imp: 8.3A | 6 pcs in serial | 6 | 1500W |
| -Voc: 37.7Vdc | 8 pcs in serial | 8 | 2000W |
| -Isc: 8.4A | 12 pcs in serial | 12 | 3000W |
| -Cells: 60 | 13 pcs in serial | 13 | 3250W |
| 8 pcs in serial and 2 sets in paralleled | 16 | 4000W |
4.3 System Wiring Diagram

4.4 Communication and Setting of Lithium Battery (BMS)
To enable communication with a Lithium Battery Management System (BMS), connect an RJ45 communication cable between the inverter and the battery. Ensure that the lithium battery BMS port's PIN configuration corresponds with the inverter BMS communication port.
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |

5. Operating Instructions
The SUMRY EP4200-H offers flexible operating modes to suit various energy needs.
5.1 Charging Modes
The inverter supports three distinct charging modes:
- Solar First: Prioritizes solar power for charging batteries and supplying loads.
- Solar and Utility: Uses solar power as the primary source, supplementing with utility grid power when solar is insufficient.
- Only Solar: Charges batteries and powers loads exclusively from solar energy.
5.2 Output Modes
The inverter provides three output modes:
- SUB (Solar-Utility-Battery): Solar power is the primary source, followed by utility grid, then battery.
- SBU (Solar-Battery-Utility): Solar power is the primary source, followed by battery, then utility grid.
- MKS (Utility-Solar-Battery): Utility grid is the primary source, followed by solar, then battery.

5.3 Monitoring and Control
- LCD Display: The integrated LCD screen provides real-time information on input, output, battery status, and load.
- Optional WiFi Module: For enhanced monitoring, an optional WiFi module can be connected to the inverter. This allows you to monitor and control the system remotely via the "Sun house App" on your smartphone or tablet.

5.4 Settings
- Charging Current: The charging current can be set through the LCD interface according to battery requirements.
- Utility Grid Input Voltage Range: The input voltage range of the utility grid can be selected based on the requirements of the connected loads (e.g., household appliances, personal computers).
6. Maintenance
The SUMRY EP4200-H is designed for low maintenance. Regular checks can help ensure optimal performance and longevity.
- Cleaning: Periodically clean the exterior of the inverter to prevent dust buildup. The unit features a dustproof design and a built-in anti-dust kit, but external cleaning is still recommended.
- Ventilation: Ensure that the ventilation openings are clear and not obstructed to allow for proper airflow and heat dissipation.
- Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
- Environmental Conditions: Ensure the inverter is operating within its specified environmental conditions (temperature, humidity).
7. Troubleshooting
The inverter is designed with self-protection features. If the inverter enters a fault state, the fault indicator (4 in Figure 6) will illuminate, and an error code may be displayed on the LCD screen. Refer to the specific error codes in the full product manual for detailed troubleshooting steps.
Common issues and their general causes:
- Overload: Reduce the connected load.
- Overheating: Ensure adequate ventilation and clear any obstructions around the cooling fins.
- Short Circuit: Check output wiring for short circuits.
- Overcurrent: Inspect connected devices for faults causing excessive current draw.
- Battery Issues (High/Low Voltage): Check battery connections, voltage, and health. Ensure battery settings in the inverter match the connected battery type.
If the issue persists after basic troubleshooting, contact customer support.
8. Specifications
The SUMRY EP4200-H inverter comes in two main power configurations depending on the battery voltage.
| Parameter | Value |
|---|---|
| Model | EP-4200H 2300W |
| Max. PV Array Power | 4000W |
| Battery Voltage | 12VDC |
| MPPT Voltage Range | 55-500VDC |
| Output Voltage | 230VAC ±5% |
| Max. Charge Current | 100A |
| Frequency Range | 50/60Hz |
| Surge Power | 4600W |
| Parameter | Value |
|---|---|
| Model | EP-4200H 4200W |
| Max. PV Array Power | 4000W |
| Battery Voltage | 24VDC |
| MPPT Voltage Range | 55-500VDC |
| Output Voltage | 230VAC ±5% |
| Max. Charge Current | 100A |
| Frequency Range | 50/60Hz |
| Surge Power | 8400W |
| Parameter | Value |
|---|---|
| Size | 40*35*19cm |
| Weight | 6.7kg |
| Output Type | SINGLE |
| Origin | Mainland China |
| Certification | CE |
| Is Smart Device | Yes (with optional WiFi module) |

9. User Tips
- Remote Monitoring: Consider purchasing the optional WiFi module to enable remote monitoring and control of your inverter via the Sun house App. This allows you to check system status and adjust settings from anywhere.
- Battery Compatibility: When selecting batteries, ensure they are compatible with the inverter's 12V or 24V system and match one of the supported types (GEL, LI, AGM, USER, FLD) for optimal performance and charging.
- Professional Installation: For safety and optimal performance, always have the inverter installed by a qualified electrician or solar professional.
10. Warranty and Support
For specific warranty details, including coverage period and terms, please refer to the documentation provided at the time of purchase or contact the SUMRY Official Store directly. Warranty information can vary by region and seller.
For technical support, troubleshooting assistance, or any inquiries regarding your SUMRY EP4200-H solar inverter, please contact the SUMRY Official Store or your authorized dealer. Provide your product model number (EP4200-H) and any relevant purchase details when seeking support.