1. Introduction
The GEYA GPS6 Series Surge Protective Device (SPD) is designed to safeguard electrical systems and on-loading electrical apparatus from damage caused by thunder and instantaneous over-voltage. This device is applicable to power systems such as TN-S, TN-C-S, TT, and IT with an AC frequency of 50/60Hz and a voltage of 380V. It is intended for installation on the connectors of LPZ1 or LPZ2 and LPZ3 zones, adhering to IEC61643-1 and GB18802.1 standards. Each module of the surge protection device includes a fault relief device.

2. Product Features
- Internal Protection: Equipped with internal overcurrent and overheat protection, featuring open temperature control.
- Modular Design: Convenient module design allows for easy installation and online replacement.
- Performance: Exhibits low leakage current, rapid response time, and reduced residual voltage.
- Status Indication: Includes a signal indication device: green indicates normal operation, while red signifies an abnormal or fault state.
- Advanced Technology: Utilizes new technology with high energy, gap discharge electrode (N-PE).
- Material Quality: The shell is constructed from UL94-V0 flame-retardant PC material, ensuring high protective insulation and preventing fire hazards in case of line faults.
- Manufacturing Precision: Features fully automatic soldering for stable soldering points, minimizing premature indicator changes.
- Certified Components: Incorporates core components with certification certificates for enhanced stability and quality.

3. Specifications
| Attribute | Value |
|---|---|
| Brand Name | GEYA |
| Model Number | GSP6-C40 |
| Type | Residual Current, Circuit breaker |
| Poles | 1P/2P/3P/4P |
| Rated Voltage (Uc) | 275VAC |
| Nominal Discharge Current (In (8/20µs)) | 20kA |
| Maximum Discharge Current (Imax (8/20µs)) | 40kA |
| Voltage Protection Level (Up) | 1.5kV |
| Response Time | ≤25 NS |
| Protection Grade | IP20 |
| Operating State Indication | Green (Normal) |
| Fault Indication | Red (Abnormal) |
| Certification | CE, RoHS |
| Is Smart Device | Yes |


4. Setup and Installation
The GSP6 series SPD is designed for installation on a 35mm standard DIN rail. Ensure all power is disconnected before attempting installation.
4.1 Installation Steps
- Mount the SPD unit securely onto a 35mm DIN rail. The guide buckle design facilitates easier installation.
- Connect the appropriate wiring according to the specific pole configuration (1P, 2P, 3P, or 4P) of your system. Refer to the wiring diagrams below.
- Ensure all connections are tight and secure.
- Verify the operating state indicator is green after power is restored.

4.2 Wiring Diagrams
Below are the wiring diagrams for different pole configurations. Always ensure proper grounding (PE) connection.




5. Operating Instructions
Once installed and connected to the power system, the GSP6 SPD operates automatically to protect against surge voltages. There are no user-adjustable settings.
5.1 Status Indicator
Each module of the SPD is equipped with a visual status indicator:
- Green Indicator: Signifies that the surge protective device is operating normally and providing protection.
- Red Indicator: Indicates that the surge protective device has absorbed a significant surge and is no longer providing protection. The module needs to be replaced.

6. Maintenance
The GSP6 SPD is designed for minimal maintenance. Regular visual inspection is recommended.
- Visual Inspection: Periodically check the status indicator on each module. If any indicator is red, the corresponding module has reached its end-of-life and requires replacement.
- Module Replacement: In case of a red indicator, the faulty module can be replaced online without disconnecting the entire system, thanks to its modular design. Ensure to follow all safety procedures and disconnect power to the specific circuit before replacing a module.
- Cleaning: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
7. Troubleshooting
The primary troubleshooting step for the GSP6 SPD involves checking the status indicator.
- Problem: Red indicator light is on.
- Solution: A red indicator signifies that the module has absorbed a surge and is no longer functional. The module needs to be replaced. Refer to the 'Maintenance' section for replacement procedures.
- Problem: No indicator light or device not functioning as expected.
- Solution: Ensure proper power supply to the circuit and correct wiring connections. If the issue persists, consult a qualified electrician.
8. User Tips
- Always ensure the power is completely off before performing any installation or maintenance work on electrical systems.
- For optimal protection, ensure the SPD is correctly matched to your electrical system's voltage and current specifications.
- Regularly check the status indicators, especially after severe weather conditions, to ensure continuous protection.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact GEYA customer service or your authorized dealer. Keep your purchase receipt as proof of purchase.