1. Introduction
Thank you for choosing the COOSPO X1 Mini Electric Bike Pump. This manual provides essential information for the safe and efficient operation and maintenance of your device. Please read it thoroughly before use.

2. Specifications
2.1 Basic Parameters
| Parameter | Value |
|---|---|
| Product Name | Mini Bike Pump |
| Product Model | AP-X1 |
| Product Dimensions | 72*53*30mm |
| Inflation Pressure Range | 3-120psi |
| Pressure Measurement Range | 3-150psi |
| Sensor Accuracy | ±1psi |
| Battery Capacity | 500mAh (3.7Wh) |
| Charging Port | USB Type-C |
| Input Parameters | 5V-2A |
| Charging Time | Less than 1 hour |
| Operating Temperature | Charging: 0°C to 45°C, Discharging: -10°C to 45°C |
| Storage Temperature | -10°C to 45°C |
| Operating Noise | 80 dB at 1 meter distance |
| Screen Size | 16.25*14mm |
| Weight | 127g (from image) |
2.2 Inflatable Performance Reference

*Laboratory data, and may vary due to changes in test environment, conditions and other factors.
2.3 Common Unit Conversion
1 bar = 14.5 psi
1 bar = 100 kPa
1 psi ≈ 1 lbs
3. Setup
3.1 Package Contents

- COOSPO X1 Mini Electric Bike Pump
- USB Type-C Charging Cable
- User Manual (PDF available here)
- Presta Valve Adapter × 1
- Needle Valve × 1
- High-Pressure Hose (with Schrader Valve x1)
3.2 Charging the Pump
Before using the pump for the first time, fully charge it. Connect the charging cable to a 5V USB adapter (not included) to charge the pump.
Charging Status Indicators:
- Charging: The battery indicator flashes.
- Fully Charged: The battery indicator stops flashing (pump is off).
Note: The pump is off during charging and cannot be used. Please purchase a safety-approved adapter separately.
3.3 Nozzle Connection

Presta Valve
Connect the pump nozzle directly to the Presta valve to inflate. Keep the nozzle pressed tightly during inflation. Before using the Presta valve, screw the tire valve nut to the top and secure it.
Schrader Valve
Connect the pump nozzle to the included high-pressure hose, then connect the hose to the tire's Schrader valve to inflate.
Needle Valve
Connect the pump nozzle to the needle valve or the included high-pressure hose with the needle valve, then insert the needle valve into the ball's inflation hole to inflate.
4. Operation
4.1 Power On/Off
- Power On: Press and hold the power/start button for about 2 seconds.
- Power Off: To turn off, press and hold the power/start button. The pump will also turn off automatically after 3 minutes of inactivity.

4.2 Pressure Detection
When the pump is powered on, connect it to the object you wish to measure. The display will show the current pressure. The pump's pressure measuring range is 3-150 psi.
4.3 Preset Inflation Pressure
The pump's pressure unit is psi, with an adjustable range of 3-120 psi.
Preset Pressure Adjustment: Before inflating, adjust the preset pressure by short pressing "+" or "-" for fine adjustment, or long pressing for quick adjustment. When adjusting, the number will flash to indicate the target pressure. The value is saved and will display the last set pressure after turning the pump on.
4.4 Inflation Operation
In the powered-on state, press the start/stop button to begin inflating. The display will show the real-time pressure. If there is no pressure change for over one minute, inflation will stop automatically. Please check if the tire is leaking.
Safety Tip: Before inflating, read the manual or related information to ensure you know the correct pressure. Do not overinflate to avoid the risk of explosion and injury. During inflation, the noise level is about 80dB. Please take precautions.
4.5 Stop Inflation
When the pressure reaches the set value, the pump will stop automatically. You can also stop it manually by pressing the start/stop button.
Special Reminder: Balloon, toy, swimming ring, and other items with lower inflation pressure than the pump's range will not stop automatically. Use with caution.
4.6 Unscrew the Nozzle
The nozzle and hose may be hot after inflation. Be careful to avoid burns. A small amount of air may leak out when removing; do it quickly.
5. Maintenance
5.1 Battery Care
- Do not disassemble, hit, squeeze, or cut the battery, as this may cause explosion or leakage.
- Stop using if the battery shows obvious swelling and dispose of it properly.
- Ensure the battery compartment is securely closed. If it cannot close completely, stop using the device immediately and keep it away from children.
- Do not throw the battery in regular trash. Follow local regulations and take used batteries to a professional recycling facility for safe disposal.
- If not used for over 3 months, it is recommended to charge the pump once to maintain battery health.
5.2 General Care
- Avoid overheating, impact, or water to prevent fire or explosion.
- Store the pump within the recommended temperature range of -10°C to 45°C. Extreme cold or heat may shorten battery life.
- Use a qualified adapter and the original charging cable for charging.
6. Troubleshooting
| Problem | Solution |
|---|---|
| Slow Inflation Speed |
|
| Unable to Inflate After Powering On |
|
| Normal Inflation but Pressure Shows Zero | Low-pressure items, such as balloons, are not within the pump's measuring range. |
| Pump Turns Off Automatically After Nozzle is Tightened | Press and hold the power/start/stop button to turn the pump back on. |
| Air Leakage When Connecting the Hose | Tighten the nozzle securely. |
| Battery Indicator Color Changes During Inflation | The battery voltage drops during use, which may cause the indicator light to change or dim. This is normal and not a malfunction. |
| Unable to Power On | Make sure the battery is fully charged. |
| Unable to Inflate / Unable to Detect Pressure |
|
| Error Code H, L | The temperature is out of range. Let the pump cool at room temperature for 1 hour before using. |
| Error Code E1 | The pressure is out of range. Remove the nozzle to see if it resets. If the error code disappears, check if the inflated item's pressure exceeds the range. |
If the product makes unusual sounds or gets too hot, turn it off immediately. If any issues occur, try restarting. If it doesn't return to normal, please contact customer service.
7. User Tips
- Charging Indicator: The battery indicator will flash while charging and stop flashing when fully charged. A full charge typically takes less than 1 hour.
- Adapter Compatibility: Always use a 5V USB adapter for charging. Ensure it is safety-approved.
- Presta Valve Preparation: When using the Presta valve, remember to unscrew the tire valve nut to the top and secure it before connecting the pump for inflation.
- Over-inflation Prevention: For items like balloons or toys that have very low pressure requirements, monitor the inflation process closely as the pump may not automatically stop.
8. Support
For further assistance or inquiries, please contact COOSPO support:
- Website: www.coospo.com
- E-mail: support@coospo.com
- Phone: +86 (755) 23594795
The information contained in this manual is for reference only. The product described above may be subject to alteration owing to the manufacturer's continuing research and development plans without prior notice.