TZONE TT19

Rate this product if you’ve used it
Contents

TZONE TT19 Real Time Data Logger User Manual

Model: TT19

1. Introduction

The TZONE TT19 is a sophisticated 4G real-time temperature and humidity data logger designed for precise environmental monitoring. It integrates temperature, humidity, light, vibration, and location tracking capabilities, making it ideal for applications requiring continuous and reliable data collection, such as cold chain transportation, pharmaceutical storage, and environmental control. This manual provides essential information for setting up, operating, and maintaining your TT19 data logger.

Front view of the TZONE TT19 Real Time Data Logger showing its LCD display and buttons.
Front view of the TZONE TT19 Real Time Data Logger.

2. Key Features

  • Built-in Vibration Monitoring: Supports trend warning and vibration monitoring to detect physical disturbances.
  • Built-in Alarm System: Provides real-time monitoring of data changes and triggers immediate alarms for critical events.
  • High-Accuracy Position System: Supports LBS, WiFi, and GPS positioning for precise location tracking and full trajectory dynamic playback.
  • Automatic Data Generation: PDF reports can be directly downloaded via USB port or accessed remotely through the TZONE cloud platform.
  • Intuitive LCD Indication: The LCD presents all key information including signal status, alarm status, and remaining battery volume for easy monitoring.
  • Comprehensive Monitoring: Tracks temperature, humidity, light, and vibration to prevent and address risks associated with environmental fluctuations, low light, and physical impacts.
  • Rechargeable Battery: Equipped with a built-in 3.7V/4000mAh Lithium Battery for extended use.
  • Robust Design: IP64 waterproof level ensures durability in various environments.
Diagram illustrating the key features of the TT19 data logger, including vibration monitoring, alarm, high-accuracy position, automatic data generation, and intuitive LCD indication.
Key features of the TT19 data logger.

3. Specifications

AttributeValue
Product Name4G real-time temperature & humidity data logger
Monitoring InformationTemperature, Humidity, Location, Light, Vibration
Working Temperature Range-20°C to +60°C
Working Humidity Range5% to 95% (non-condensing)
Position TypeLBS, WiFi, GPS positioning
USB InterfaceUSB-C
Dimensions100 x 66 x 29mm
Memory Capacity17,000 readings
Battery Life120 days (Default 1 hour interval)
Inner Lithium BatteryBuilt-in 3.7V/4000mAh Lithium Battery
Net Weight165g
IP RatingIP64
Data Transmit Interval60 minutes
Transmission Mode4G/2G (LTE CAT1; LTE-FDD B1,B2,B3,B4,B5,B7,B8,B20,B28,B66; GSM: 850/900/1800/1900MHz)
Resolution0.1
Other SensorLight and vibration sensors
CertificationCE

4. Setup Guide

4.1. Installing a SIM Card

The TT19 requires a 4G/2G SIM card for real-time data transmission. Follow these steps to install it:

  1. Carefully open the casing of the TT19 data logger.
  2. Locate the SIM card slot on the circuit board.
  3. Insert the SIM card into the slot, ensuring it is correctly oriented.
  4. Gently press the SIM card until it clicks into place.
Play video
Watch video online
Video demonstrating the installation of a SIM card and battery connection.

4.2. Connecting the Battery

After installing the SIM card, connect the internal lithium battery:

  1. Locate the battery connector on the circuit board.
  2. Plug the battery cable into the connector.
  3. Carefully close the device casing, ensuring it is securely fastened.

4.3. Powering On

To turn on the TT19 data logger:

  1. In the off state, press and hold the "START" button for more than 3 seconds.
  2. The "OK" LED will light up in green.
  3. The LCD display will show temperature values, indicating the device is turned on and has begun uploading data to the cloud immediately.
Image showing how to turn on the TT19 data logger by long-pressing the START button.
Instructions for powering on the TT19 data logger.

5. Operating Instructions

5.1. Powering Off

To turn off the TT19 data logger:

  1. In the on state, press and hold the "STOP" button for more than 3 seconds.
  2. The "Alarm" LED will light up in red.
  3. The LCD display will turn off, indicating the device is powered down and has uploaded its final data to the cloud.
Image showing how to turn off the TT19 data logger by long-pressing the STOP button.
Instructions for powering off the TT19 data logger.

5.2. Device Placement

For accurate monitoring, place the TT19 in the desired environment. For cold chain applications, ensure it is placed within the refrigerated container or area where temperature and humidity need to be tracked.

The TT19 data logger being placed into a cooler for cold chain monitoring.
Proper placement of the TT19 in a refrigerated environment.

6. Data Access and Monitoring

The TT19 data logger provides multiple ways to access and monitor your collected data:

6.1. TZONE Cloud Platform

The primary method for real-time monitoring and data analysis is through the TZONE Cloud Platform. This platform allows you to:

  • View real-time temperature, humidity, light, vibration, and battery status.
  • Access historical data charts and lists.
  • Track GPS location data and full trajectory playback in real-time.
  • Download PDF data reports at any time.
Diagram showing how the TT19 data logger connects to the TZONE Cloud Platform for data processing, real-time monitoring, data reports, GIS geographic information, and equipment management.
Overview of the TZONE Cloud Platform functionality.

6.2. USB Data Download

For local data access, connect the TT19 to a computer via its USB-C interface. The device can generate PDF reports directly, which can then be downloaded and saved.

7. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Charging: Ensure the device is regularly charged using the provided USB-C cable to maintain optimal performance and continuous data logging.
  • Storage: When not in use for extended periods, store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Firmware Updates: Periodically check the TZONE website or cloud platform for any available firmware updates to ensure your device has the latest features and bug fixes.

8. Troubleshooting

  • Device Not Turning On: Ensure the battery is connected and fully charged. Try pressing and holding the START button for longer than 3 seconds.
  • No Data Transmission: Check if the SIM card is correctly installed and has an active 4G/2G plan. Verify network coverage in the device's location. Ensure the device is powered on.
  • Inaccurate Readings: Ensure the device is placed in an environment free from direct heat sources, extreme drafts, or direct sunlight that could affect sensor accuracy. Allow the device to stabilize for a few minutes after placement.
  • Cloud Platform Connectivity Issues: Verify your internet connection. Ensure the device ID is correctly entered on the cloud platform.
  • PDF Report Generation Failure: Ensure the device has sufficient memory. Try connecting to a different USB port or computer.

9. Warranty and Support

The TZONE TT19 Real Time Data Logger comes with a one-year warranty from the date of purchase. For technical support, warranty claims, or any inquiries regarding your device, please contact TZONE Digital Technology Co. Ltd. directly. Refer to the official TZONE website for contact information and further support resources.

Collage of various certifications for TZONE products, including NIST Calibration Report, ISO 9001, CE Certification, EN 12830 Certification, FCC Certification, and TELEC Certification.
Certifications for TZONE products, ensuring quality and compliance.

10. User Tips

  • For optimal battery life, ensure the device is fully charged before long deployments.
  • Regularly check the signal strength indicator on the LCD to confirm stable 4G/2G connectivity for real-time data uploads.
  • Utilize the TZONE Cloud Platform's alert features to receive immediate notifications for any deviations from your set temperature or humidity thresholds.
  • When using the device in cold chain applications, place it centrally within the cargo to get a representative reading of the environment.

Documents and downloads