JIKONG JK-B1A8S20P

Contents

JIKONG JK-B1A8S20P Smart Active Balance BMS Instruction Manual

Model: JK-B1A8S20P

1. Introduction

The JIKONG JK-B1A8S20P is a Smart Active Balance Battery Management System (BMS) designed for various lithium battery types, including LiFePO4, Li-Ion, and LTO. This BMS provides comprehensive protection and active balancing to ensure the longevity and optimal performance of your battery pack. It features mobile app connectivity via Bluetooth for real-time monitoring and parameter adjustment.

Video: A 360-degree view of the JIKONG JK-B1A8S20P BMS unit.

2. Key Features

  • Active Balance: Real-time active energy transfer equalization using a supercapacitor medium, ensuring good durability, long life, and stable performance.
  • High Accuracy: Single voltage range of 1V~5V with an equalization accuracy of ±5mV.
  • Continuous Balanced Current: Achieves 2-10A continuous balanced current to maintain battery consistency, improve cruising range, and delay battery aging.
  • Mobile Connectivity: Bluetooth communication with a dedicated mobile APP (Android and iOS) for real-time battery status monitoring.
  • Scalability: Supports balanced cascading, suitable for battery packs with more than 24 series.
  • Versatile Compatibility: Compatible with LiFePO4, ternary lithium, and lithium titanate (LTO) battery types.
  • Comprehensive Protection: Includes Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection, Dropout Protection, and Over Temperature Protection.
  • Interfaces: Features Bluetooth, RS-485, and optional GPS/CAN interfaces (customization may be required).
JIKONG JK-B1A8S20P BMS highlighting key features like 4S-8S battery strings, 1A balance current, and 200A charge/discharge.

Image: Overview of the JK-B1A8S20P BMS with its main functions and specifications.

3. Package Contents

The standard package for the JK-B1A8S20P BMS includes:

  • 1 x BMS Unit (with Bluetooth built-in)
  • 1 x Temperature Sensor (40cm cable length)
  • 1 x Set of Balance Wires (75cm cable length)
  • 1 x Active Switch (15cm cable length)
  • 1 x Heating Cable (Only included for BMS models with Heat Function, denoted by 'H')

Note: BMS models with 'H' include the heating function, and 'C' indicates a built-in CANBUS chip. RS485, LCD, and other BMS accessories may not be universally compatible across all B1A8S20P/B2A8S20P variants due to differing voltage ranges. Please verify compatibility when purchasing additional accessories.

4. Setup and Wiring

4.1 Basic Wiring Diagram

The following diagram illustrates the basic connection of the BMS to your battery pack, controller, and charger. Ensure all connections are secure and correctly polarized.

Basic wiring diagram for JIKONG BMS showing connections for B+, B-, P-, controller, charger, and individual battery cells.

Image: Basic wiring diagram for the JIKONG BMS.

4.2 5-Step Wiring Method

Follow these steps for proper installation of the BMS, using a series connection as an example:

  1. Connect P- and B-: Find the P- and B- positions on the protection board. Connect the corresponding black row of wires to B-. Ensure the cable is not inserted into the protection board initially.
  2. Find Total Negative Terminal: Identify the total negative terminal of your battery pack. This is the first string of batteries.
  3. Connect Balance Wires: Connect the first wire to the negative terminal of the battery, the second wire to the positive terminal of the first series of batteries, and so on. The wires must be connected in order; do not skip any strings.
  4. Measure Voltage: Use a multimeter to measure the voltage between each 2S or more strings. For ternary batteries, the range is 3V-4.2V; for iron batteries, it's 2.5V-3.6V. If the measurement is outside this range, it indicates incorrect wiring. Ensure the line must be connected to the right before plugging into the protection board. Incorrect wiring can damage the board.
  5. Final Connection: After confirming all wires are correctly connected, connect B- to the total negative terminal of the battery (wire length within 15cm is recommended). Then, insert the connected wires, measure the protection board B- and the total positive voltage. This should equal the total positive voltage of the P- and the total positive voltage. Finally, connect the P- welding charging and discharging interface negative terminal to the total positive terminal connected to the charging and discharging interface positive terminal.
Detailed 5-step wiring method for JIKONG BMS, including multimeter checks and connection points.

Image: Step-by-step guide for wiring the JK BMS.

4.3 BMS Interface Description

The BMS unit features several interfaces for various functions:

  •  ① Temperature Sensor: For monitoring battery temperature.
  •  ② RS485 Interface: All JK BMS models are configured with RS485 by default.
  •  ③ LCD Interface: All JK BMS models (except JK-BD4A17S4P) are configured with an LCD interface by default.
  •  ④ Heat Function Interface: For connecting heating elements (customization may be required).
  •  ⑤ CANBUS Interface: Requires customization.
Close-up of JIKONG BMS interfaces including temperature sensor, RS485, GPS, LCD, and heat function ports.

Image: Detailed view of the BMS interfaces.

4.4 Parallel Operation

If you intend to use multiple BMS units in parallel, it is crucial to add a Fast Class T Fuse to each battery pack. Alternatively, a discharge diode (high power diode selected according to load) can be used.

Diagram illustrating parallel operation of LiFePO4 batteries with individual BMS units and Fast Class T Fuses connected to bus bars.

Image: Diagram for parallel operation of LiFePO4 batteries with individual BMS units.

5. Operating Modes and App Usage

5.1 Smart Energy Working Modes

The BMS operates in several smart energy modes to optimize battery life and safety:

  • Storage Mode: In transportation, storage, offline, or wireless transmission off mode, the BMS enters storage mode and does not consume battery pack current.
  • Normal Working Mode: When the charger is inserted in storage mode and turned off, the BMS returns to normal working mode. All protection functions, equalization functions, and communication functions become active.
  • Shutdown Mode: To prevent power wastage during long periods of inactivity or battery pack damage, the BMS automatically shuts down when a cell falls below the shutdown voltage.
  • Standby Mode: When the battery pack is in a static state (no charge or discharge current and no equilibrium current), the BMS automatically enters standby state after a set time (1-30 days, configurable).
Flowchart illustrating Smart Energy Working Mode Switching: Storage, Normal Working, Shutdown, and Standby modes.

Image: Smart Energy Working Mode Switching diagram.

5.2 Mobile APP Usage

The JIKONG BMS mobile application allows you to monitor and manage your battery pack in real-time. It supports active balancing and provides detailed battery information.

The app provides various screens for basic settings, advanced settings, cell voltage monitoring, and more.

Screenshots of the JIKONG BMS mobile app showing battery status, cell voltages, and settings for active balancing.

Image: Mobile APP interface displaying battery data and settings.

5.3 Heating Function (If applicable)

For BMS models equipped with the heating function, the green 5PIN cable of the heating cable connects to the heating pad. The black and red cables connect to a smart charger. The smart charger, linked to the BMS, detects battery temperature and automatically manages the heating function when the battery temperature falls below the low-temperature charge protection threshold. This threshold is a configurable parameter within the APP.

The heating power is dependent on the battery voltage and the resistance value of the heating film.

6. Maintenance

The JIKONG BMS is designed for low maintenance. Its active balancing feature helps maintain battery cell consistency, which is crucial for prolonging battery life and performance. Regularly check the mobile app for any alerts or abnormal readings. Ensure all wiring connections remain secure and free from corrosion. Keep the BMS unit clean and free from dust and moisture.

7. Troubleshooting

7.1 No Power On

  • Ensure the last "B+" line is connected to the battery's total positive pole.
  • Activate charging: The charger voltage must be more than 4V above the battery pack voltage to activate the BMS.
  • Verify charger output: Check if the charger is providing voltage output.

7.2 Voltage Inaccuracy

Measure the actual total voltage of the battery pack using a multimeter. Enter this actual total voltage into the "Voltage Calibration" setting within the mobile application's parameter settings page.

7.3 Current Inaccuracy

  • The BMS B- and P- connections use two 7AWG wires. Both must be connected in parallel; otherwise, it may lead to current errors.
  • Use a clamp meter to measure the actual current of the battery pack. Enter this actual current into the "Current Calibration" setting within the mobile application's parameter settings page. Higher actual current measurements will result in higher calibration accuracy.

7.4 Capacity Inaccuracy

  1. Set Battery Capacity: Initially set the battery capacity in the app. If your battery is 100AH, you can set it slightly higher, e.g., 120AH or 150AH.
  2. Discharge Battery: Discharge the battery using an electrical instrument until the protection board indicates a single undervoltage protection.
  3. Charge Battery: Charge the battery without interruption until the BMS indicates single-unit over-voltage protection.

After completing these steps, the capacity will automatically update in the APP, showing the actual battery capacity and ensuring accurate SOC (State of Charge) readings.

7.5 Mismatch in Number of Strings

  • Verify that the "number of single unit" parameter in the app settings is correctly configured.
  • If there is no voltage in the middle of 2S or more strings, check if the collection line is disconnected or loose.
Diagram showing six security protection features: Overcharge, Short circuit, Over discharge, Over current, Dropout, and Over temperature protection.

Image: Six security protection features of the BMS.

8. Specifications

The following table outlines the general specifications for the JIKONG Smart Active BMS, with specific details for the JK-B1A8S20P model highlighted where applicable.

Attribute Value (JK-B1A8S20P)
Brand Name EZKABO (JIKONG)
Type LiFePO4 Battery BMS
Handware or Smart SMART BMS
Battery Series 4S 5S 6S 7S 8S
Charging Current 200A
Continuous Discharge Current 200A
Balance Function Active Balance (1A)
Single Voltage Range 1V~5V
Balance Acquisition Accuracy ±5mV
Overcharge Protection Voltage 1.2-4.35V Adjustable
Overcharge Release Voltage 1.2-4.35V Adjustable
Over Current Detect Delay 2-120S Adjustable
Over Discharge Protection Voltage 1.2-4.35V Adjustable
Over Discharge Release Voltage 1.2-4.35V Adjustable
Short Circuit Protection Yes
Over Temperature Protection Yes
Bluetooth Yes (Support for Android/iOS phone)
RS-485 Yes
GPS According to Customer need
CAN According to Customer need
Certification CE, RoHS
Dimensions (B1A8S20P) 162*102*20mm
Comprehensive product specifications table for various JK Smart Active BMS models, including balance current, continuous charge/discharge current, and dimensions.

Image: Detailed product specifications for JK Smart Active BMS models.

9. User Tips

  • Port Configuration: Understand the difference between 'same port' (charge and discharge share one interface) and 'separate port' (charge and discharge have distinct interfaces) to ensure correct wiring and current handling.
  • BMS Current Selection: The BMS current rating should primarily be determined by the current limit of your controller, which in turn depends on your motor's power. Always choose a BMS with a continuous current rating greater than your controller's current limit, allowing for a safety margin.
  • Charger Compatibility: Always use a charger specifically designed for your battery chemistry (e.g., LiFePO4 charger for LiFePO4 batteries). Using a lead-acid battery charger can damage the BMS.
  • Voltage for Chargers: For LiFePO4 batteries, the charger voltage should be 3.65V per cell. For ternary lithium batteries, it should be 4.25V per cell, multiplied by the number of series.

10. Warranty and Support

JIKONG products are designed for reliability and performance. For any issues or support, please refer to the seller's return and refund policy. The product includes a delivery guarantee, which may offer compensation in case of delayed delivery, lost packages, or damaged items.

For detailed information regarding return and refund policies, please consult the official seller's terms and conditions.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.