1. Important Safety Instructions
Before using this product, please read and understand all instructions in this manual. Retain this manual for future reference.
Intended Use
- This product is for household use only.
- Use only as described in this manual.
Product Condition
- Do not use the product if it is damaged in any way.
User Suitability
- This product is intended for persons aged 18 years and above.
- It may be used by persons with reduced physical, sensory or mental capabilities, or lack of experience/knowledge, only if they are supervised or instructed on safe use and understand the hazards involved.

Manufacturer: Guangzhou Aicai Technology Co., Ltd. | Made In China
2. Product Overview
The Tuya WiFi-3188 is a versatile 7-in-1 water quality monitor designed for real-time measurement and monitoring of various water parameters. It connects to your smartphone via WiFi for convenient data access and alerts.
Key Features
- Smart WiFi Connectivity: Connects to your phone via the Tuya app for instant access to real-time and historical data, including high and low alerts.
- Comprehensive Multi-Parameter Testing: Simultaneously measures pH, ORP, EC, PPM, CF, humidity, and temperature.
- User-Friendly Operation: Features an easy-to-read LCD with adjustable backlight and simple controls.
- App-Based Data Logging: Records long-term monitoring data for trend analysis and improved water management.
- High-Precision Replaceable Electrodes: Equipped with accurate, replaceable electrodes suitable for various applications like aquariums, hydroponics, and pools.
Components

The main unit, probe, and power adapter.

Multifunctional and removable electrode with quick response.
3. Setup Guide
- Unpack: Carefully remove all components from the packaging. Ensure you have the main monitor unit, the electrode probe, and the power adapter.
- Connect the Probe: Securely connect the electrode probe to the main monitor unit. The probe is designed for easy attachment and detachment.
- Power Connection: Connect the power adapter to the monitor unit and plug it into an appropriate power outlet (EU AC220V or US AC110V, depending on your model). The device will power on automatically.
- App Installation: Download the 'Tuya Smart' app from your smartphone's app store (compatible with iOS and Android systems).
- WiFi Connection: Follow the in-app instructions to connect your monitor to your home WiFi network. This will enable real-time data viewing and alerts on your smartphone.
- Initial Calibration: Before first use, it is recommended to perform a calibration for pH and EC/PPM/CF. Refer to the detailed PDF manual for specific calibration procedures using standard buffer solutions. The device features 'CAL' buttons on the display for this purpose.

Monitor with power adapter.
4. Operating Instructions
Taking Measurements
- Immerse the Electrode: Submerge the electrode probe into the water sample you wish to test. Ensure the sensor part is fully immersed.
- Read LCD Display: The monitor's LCD screen will display real-time readings for EC/PPM/CF, pH/ORP, and Temperature/Humidity.
- Switching Modes: Use the 'MODE' buttons below the EC/PPM/CF and pH/ORP displays to cycle through the different parameters.
- Temperature Units: Use the '°C/°F' button to switch between Celsius and Fahrenheit temperature units.
Using the Tuya App
- Real-Time Viewing: Open the Tuya Smart app on your smartphone to view current water quality data remotely.
- Data Logging: The app automatically records long-term monitoring data, allowing you to review historical trends (Day, Week, Month) and analyze changes over time.
- Setting Alerts: Configure custom high and low alert thresholds for each parameter within the app. You will receive notifications if readings fall outside your set ranges.
- Backlight Control: The app may offer options to control the backlight of the device for better visibility.

Monitor and app interface.

App real-time viewing and data analysis.
5. Maintenance
- Electrode Cleaning: Regularly clean the electrode probe with distilled water to remove any residue that may affect accuracy. For stubborn deposits, use a soft brush and a mild cleaning solution specifically designed for pH/EC probes, then rinse thoroughly.
- Electrode Storage: When not in use for extended periods, store the electrode in a suitable storage solution (e.g., KCL solution for pH electrodes) to prevent it from drying out.
- Electrode Replacement: The electrodes are replaceable. If readings become consistently inaccurate despite cleaning and calibration, consider replacing the electrode probe.
- Device Cleaning: Wipe the main unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the main unit in water.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Inaccurate readings | Dirty electrode, uncalibrated sensor, expired electrode. | Clean the electrode. Perform calibration. Replace the electrode if necessary. |
| No display/Device not powering on | Power adapter issue, loose connection. | Check power adapter and cable connections. Try a different power outlet. |
| WiFi connection failure | Incorrect WiFi password, device too far from router, router settings. | Ensure correct WiFi password. Move device closer to router. Check router settings (2.4GHz network required). Restart device and router. |
| App not showing data | Device not connected to WiFi, app not refreshed, server issues. | Verify device WiFi connection. Refresh the app. Check internet connection. |
7. Specifications
| Parameter | Range |
|---|---|
| PH Value | 0.01-14.00pH |
| ORP | -1200mV-+1200mV |
| EC | 0.00-19.00mS/cm, 20.1-200.0mS/cm |
| Total Dissolved Solids (TDS) | 0-9990ppm, 10.1-100ppt |
| Cubic Feet (CF) | 0.1-199.9CF |
| Humidity | 01%RH-99%RH |
| Temperature | 0.1°C-80.0℃ (32.1°F-176°F) |
| Plug Type | EU (AC220V) / US (AC110V) |
| Material | ABS |
| OS Requirements | Compatible with iOS and Android systems |
| Dimensions | Approx. 150mm x 80mm x 35mm (5.91in x 3.15in x 1.38in) |

Product dimensions and cable lengths.
8. User Tips
No specific user tips were available from reviews or Q&A for this product.
9. Warranty and Support
For detailed warranty information and technical support, please refer to the official user manual PDF provided by the manufacturer. This document contains comprehensive instructions for advanced features, calibration, and troubleshooting.
Official User Manual (PDF): Download PDF Manual
Manufacturer: Guangzhou Aicai Technology Co., Ltd.
Contact Information:
- Email: valhallatax@outlook.com