1. Product Overview
The JIKONG Lithium battery intelligent protection board (BMS) is a management system designed for large capacity series lithium battery packs. It integrates voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote functions. This BMS is compatible with Lithium Iron Phosphate (LiFePO4), Ternary Lithium (Li-ion), and Lithium Titanate (LTO) battery types.
The protection board utilizes energy transfer active balancing technology, capable of achieving a maximum continuous 2A balance current. This high current active equalization technology ensures battery consistency, extends battery range, and delays battery aging. The BMS is compact, easy to operate, and fully functional, making it suitable for various applications such as small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Functional Characteristics
The JIKONG JK-B2A24S-30P Smart BMS offers a comprehensive set of features to ensure optimal battery performance and safety:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support heating function (Optional)
- Support GPS communication (Optional)
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- ACC detection function
- Short circuit protection

3. Specifications
3.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <1200 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 24 | String |
| Maximum Balancing Current | 2 | A |
| Maximum Charging Current | 300 | A |
| Maximum Discharge Current | 300 | A |
| Maximum Instantaneous Current | 600 | A |
| Maximum Internal Loop Resistance | 0.21 | mΩ |
| Finished Weight | 675 | g |
3.2. Dimensions
The dimensions of the JK-B2A24S-30P series protection board are 208mm (length) x 120.7mm (width) x 15.6mm (height).

3.3. Battery Type Compatibility
| Battery Type | Adaptive Battery Strings (S) |
|---|---|
| Ternary Lithium (Li-ion) | 7-24S |
| Lithium Iron Phosphate (LiFePO4) | 8-24S |
| Lithium Titanate (LTO) | 14-24S |
4. Package Contents
The standard package for the JIKONG JK-B2A24S-30P Smart BMS typically includes:
- JIKONG JK-B2A24S-30P Smart BMS unit
- Balance wires (multi-pin connector)
- Temperature sensor wires
- Mounting screws

5. Setup and Installation
5.1. Installation Method
The JK-B2A24S-30P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always refer to the detailed wiring diagram provided.

Important Wiring Notes:
- P- Terminal: Connect to external load or negative terminal of charger. Equipped with M6 screws.
- B- Terminal: Connect to the negative battery terminal. Equipped with M6 screws.
- B+ Terminal: Connect to the battery power positive.
- Heater Element Negative Electrode (HT-): Connects to the heating wire (16AWG orange-yellow, 15CM, optional).
- Bluetooth Connection Indicator (D1): When Bluetooth is connected to the protection board, the indicator is steady on. When the connection is disconnected, the indicator blinks.
5.2. Device Activation
Before powering on the protection board, ensure the balance cable is correctly connected and that P- and B- terminals are properly connected. Verify that the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a physical power-on switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.
Alternatively, the protection board supports key activation and display activation. If you have chosen the optional display screen and button, simply insert the cable into the display interface and press the button to activate.
6. Operation Instructions
6.1. Active Equalization
The BMS uses active equalization to transfer energy from high-voltage cells to low-voltage cells. Before using this function, set the basic battery parameters in the APP. Download the JIKONG BMS APP, then set the battery type on the parameter setting page. Refer to the 'Default Parameters' section for initial values. After setting the battery type, configure the number of cells, battery capacity, trigger equalization differential pressure (default value can be retained), voltage calibration, and current calibration in the common settings.
Users can set the balance trigger pressure difference (mV) in the APP. When balancing is enabled, it automatically activates if the voltage difference between any two battery strings exceeds the set value, and deactivates when it falls below the set value. The default balance current is 2A. You can adjust this current based on your battery capacity, but it's recommended not to exceed 0.2C of the battery capacity. If balancing is not needed, it can be turned off in the BMS control page of the APP.

6.2. Heating Function (Optional)
The BMS supports an optional heating function to prevent charging and discharging issues in low temperatures. It uses a resistance heater or heating film to warm the battery. The designed heating current is 10A. Users can control this function via the BMS control page in the APP based on ambient temperature. It is recommended to install a normally closed temperature control switch (45°C to 65°C) in series with the heating circuit as a secondary protection to prevent thermal runaway. The heating circuit will cut off when the temperature reaches the switch's threshold.
6.3. Alarm Function (Optional)
The BMS includes an optional alarm function. If the BMS detects safety risks such as over-temperature, overcharge, or over-discharge, it will trigger an external alarm.
6.4. Battery Parallel Function (Optional)
For energy storage battery packs, the BMS supports an optional parallel function. This requires synchronous use with parallel modules and disabling the 'charging current limiting' function in the APP.
6.5. ACC Detection Function
The ACC detection function enables discharge. There are two ways to activate it: applying a voltage between ACC+ and ACC- (20V-100V range) or directly short-circuiting ACC+ and ACC-. Additionally, the BMS has a charger detection function (C_detect+ and C_detect- interfaces) that connects to the 12V voltage signal output of the charger to enable charging.
6.6. Protection Functions
The BMS provides comprehensive protection for your battery:
- Charge Overvoltage Protection: Standard feature. Users can set single overcharge protection and recovery voltages in the APP. If any cell exceeds the set overvoltage, charging stops. Charging resumes when all cells are below the recovery voltage.
- Discharge Undervoltage Protection: Standard feature. Users can set battery undervoltage protection, recovery, and automatic shutdown voltages in the APP. If any cell drops below the undervoltage protection value during discharge, discharge stops. Discharge resumes when all cells are above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will automatically shut down.
- Charge Overcurrent Protection: Standard feature. Users can set continuous charging current, overcurrent delay, and release times in the APP. If charging current exceeds the set value for the specified delay, charging stops. It resumes after the release time.
- Discharge Overcurrent Protection: Standard feature. Users can set continuous discharge current, overcurrent delay, and release times in the APP. If discharge current exceeds the set value for the specified delay, discharge stops. It resumes after the release time. (Note: Max continuous discharge current cannot exceed 300A).
- Over Temperature Protection: Standard feature for both charge and discharge. Users can set protection and recovery temperatures in the APP. If the temperature exceeds the set value, the respective operation (charge/discharge) stops and resumes when the temperature falls below the recovery value.
- Low Temperature Protection (Charging): Standard feature. Users can set charging low temperature protection and recovery temperatures in the APP. If the temperature drops below the set value, charging stops and resumes when the temperature rises above the recovery value. For extremely cold regions, the optional heating function is recommended.
- Short Circuit Protection: Standard feature. The current that triggers short circuit protection is pre-set. Users can adjust the short circuit protection delay (µs) and recovery time (S) in the APP. If a short circuit occurs during charging or discharging, the BMS will stop the operation and resume after the recovery time. Adjusting the delay can help prevent false triggers from high peak currents during charger startup or capacitive loads.
- Emergency Switch: Standard feature. If issues like over-temperature, over-discharge, over-charge, or cell drop occur, activating the emergency switch in the APP will enable charge and discharge for 30 minutes, providing emergency use time. The BMS will continue to operate until the 30-minute period ends, even if a cell reaches automatic shutdown voltage.
6.7. Intelligent Sleep
The BMS features an intelligent sleep function as standard, which users can enable or disable in the APP. This function puts the protection board into a low-power standby state (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. To reactivate, press a button (if available) or connect a charger.
6.8. Communication Function (Optional)
The BMS supports optional CAN and RS485 communication. Users can select these based on their requirements. When using communication, set the address and communication protocol in the APP according to your specific needs and scenarios. Refer to the JIKONG Protection Board communication protocol document for details.
6.9. APP Operation Instructions
The BMS comes with a mobile APP compatible with Android and iOS operating systems. The APP connects to the protection board via Bluetooth, allowing you to view battery status, modify parameters, and control charge/discharge switches.

To install the APP, scan the QR code below. Android Version 7 minimum is required for the Android APP.

6.10. Parameter Setting
Detailed instructions for setting protection board parameters are available in the comprehensive