1. Product Overview
The JIKONG BMS JK-BD4A series is an intelligent battery protection board designed for large-capacity series lithium battery packs. It integrates advanced features such as voltage acquisition, high-current active balancing, overcharge/over-discharge protection, overcurrent/over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS remote functionality. This system is suitable for Li-ion, LiFePO4, and LTO battery types.
The protection board utilizes energy transfer active balancing technology, which allows for a continuous balancing current of up to 0.4A. This technology significantly improves battery consistency, extends battery life, and delays aging. The compact design and comprehensive functionality make it ideal for various applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Safety Information
Please read and understand all safety instructions before installing or operating the JIKONG BMS. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Always ensure proper wiring and connections. Incorrect wiring can lead to damage to the BMS, battery, or connected devices.
- Do not attempt to open or modify the BMS unit. There are no user-serviceable parts inside.
- Ensure the BMS is securely mounted and protected from physical damage, moisture, and extreme temperatures.
- Use appropriate personal protective equipment (PPE) when working with batteries and electrical systems.
- Verify battery compatibility (Li-ion, LiFePO4, LTO) and cell count (8-24S) before connecting the BMS.
- In case of smoke, unusual odors, or excessive heat, immediately disconnect the power source and seek professional assistance.
3. Features
The JIKONG BMS JK-BD4A series offers a comprehensive set of features to ensure optimal battery performance and safety:
- Active Equalization: Energy transfer balancing with up to 0.4A continuous current, ensuring cell voltage consistency.
- Voltage Acquisition: High-precision voltage acquisition (±3mV).
- Current Acquisition: High-precision current acquisition.
- Protection Functions:
- Overcharge Protection & Recovery
- Over-discharge Protection & Recovery
- Charge Overcurrent Protection & Recovery
- Discharge Overcurrent Protection & Recovery
- Over-temperature Protection & Recovery (Charge & Discharge)
- Low-temperature Protection & Recovery (Charge)
- Short Circuit Protection & Recovery
- Communication: Bluetooth for APP control, optional RS485, optional CAN.
- Monitoring: LED Bluetooth status indicator, support for information screen display, accurate time logging.
- Smart Functions: Coulomb meter for battery capacity calculation, intelligent sleep mode, emergency switch.
- Optional Features: GPS communication, heating function, battery parallel function.
4. Specifications
The following tables detail the basic and default parameters for the JIKONG BMS JK-BD4A series. Note that some parameters are adjustable via the mobile APP.
4.1. Basic Parameters
| Item | Parameter | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 24 | Strings |
| Max. Balancing Current | 0.4 | A |
| Max. Charging Current | 100 | A |
| Max. Discharge Current | 100 | A |
| Max. Instantaneous Current | 200 | A |
| Max. Internal Loop Resistance | 1 | mΩ |
| Protective Plate Size | 146.8*103*17.6 | mm |
| Finished Weight | 230 | g |
4.2. Default Parameters (Example for 20S/24S 100A Model)
For a comprehensive list of default parameters for different battery types (Li-ion, LiFePO4, LTO), please refer to the detailed table in the official PDF manual, section 4.2. These include balancing voltage, overcharge/over-discharge protection voltages, temperature thresholds, and delay times for various protections.
4.3. Dimensions
The standard size for the JK-BD4AxxS-10P series protection board is 146.8mm × 103mm × 17.6mm. Other variants may have slightly different dimensions as shown in the diagram.
5. Setup & Installation
Careful installation is crucial for the proper functioning and safety of the BMS. Ensure all connections are correct before powering on the device.
5.1. Package Contents
- JIKONG BMS Unit
- Switch Key (1)
- Sampling Cables (2)
- NTC Temperature Sensor (1)
5.2. Component Identification
5.3. Wiring Instructions
The JK-BD4AxxS-10P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure the balance cables are properly connected and the P- and B- terminals are correctly wired.
Key Connections:
- B- (Battery Total Negative): Connects to the total negative terminal of the battery pack.
- P- (Load/Charger Negative): Connects to the negative terminal of the load and charger.
- Balance Wires (B1, B2, ..., Bn, B+): Connect these wires sequentially from the first cell's positive (B1) up to the total positive of the battery pack (B+). Ensure each wire corresponds to the correct cell positive terminal.
- NTC Temperature Sensor: Connect the NTC sensor to the designated port (P3/P4) on the BMS.
- Bluetooth Module: Connect the Bluetooth module to its dedicated port for APP communication.
- Optional Connections: RS485, CAN, LCD display, heating module, parallel module, GPS module should be connected to their respective ports as per the interface definition tables in the full PDF manual.
Interface Definition Summary:
| Connector | Interface Name | Pins | Description |
|---|---|---|---|
| P1 (HY2.0-15P) | Balance & Acquisition | B-, B1-B14 | Battery total negative, Cell positive terminals 1-14 |
| P2 (HY2.0-11P) | Balance & Acquisition | B15-B24 | Cell positive terminals 15-24 |
| P3 (HY2.0-4P) | Temperature Interface | T1A, T1B, T2A, T2B | Temperature Sensor 1 & 2 pins |
| P4 (HY2.0-4P) | Optional Temperature Interface | T3A, T3B, T4A, T4B | Temperature Sensor 3 & 4 pins (optional) |
| P5 (1.25T-4PWT) | GPS Interface | VGPS, TX, RX, GND | GPS power, UART TX/RX, Ground |
| P6 (A1254WF-2A) | Buzzer Interface (Optional) | VCC, GND | Buzzer power positive/negative |
| P7 (A1254WF-4A) | Communication Interface | RS485 B, RS485 A, CAN H, CAN L | RS485/CAN communication lines |
| P8 (A1254WF-6A) | Display Interface | VCC, A, B, GND, K+, K- | Display power, RS485 signals, Activation signals |
| P9 (A1254WF-3A) | Parallel Interface (Optional) | GND, P-EN, P-status | Ground, Parallel module enable, Parallel status |
5.4. APP Installation & Device Activation
The JIKONG BMS is controlled via a mobile APP available for Android and iOS. To install the APP:
- Scan the QR code below with your smartphone to download the official JIKONG BMS APP. (Android Version 7 minimum is required).
- Install the APP on your device.
Device Activation:
Before powering on the protection board, double-check all balance cable connections and ensure P- and B- are correctly wired. The BMS does not have a power-on control switch; it is designed for charging activation. After battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if an optional display screen and button are connected, the device can be activated by pressing the button.
6. Operation
The JIKONG BMS is primarily operated and monitored through its mobile APP via Bluetooth. The APP allows you to view battery status, modify parameters, and control charge/discharge switches.
6.1. Active Equalization
The active equalization function transfers energy from higher-voltage cells to lower-voltage cells. Before using, set basic battery parameters (number of cells, battery capacity) in the APP. You can adjust the balance trigger pressure difference (mV) in the APP settings. Equalization automatically starts when the voltage difference between any two cells exceeds the set value and stops when it falls below the set value. The default balance current is 0.4A, adjustable based on battery capacity (recommended not to exceed 0.2C).
6.2. Protection Functions
The BMS provides various protection mechanisms. Most protection parameters (e.g., voltage thresholds, temperature limits, delay times) can be configured via the APP to suit your specific battery type and usage.
- Overcharge/Over-discharge Protection: Prevents battery damage from excessive charging or discharging. The BMS will cut off charging/discharging and resume once conditions are safe.
- Overcurrent Protection: Protects against excessive charge or discharge currents. Configurable delay times prevent false triggers.
- Over/Low Temperature Protection: Monitors battery temperature during charge and discharge, cutting off operations if temperatures exceed safe limits or fall below low-temperature charging limits.
- Short Circuit Protection: Automatically protects against short circuits. Recovery occurs after a set delay.
6.3. Optional Features Operation
- GPS & Display Interface: If equipped, the GPS module provides location tracking, and the display interface allows for direct viewing of battery information.
- Heating Function: For models with heating, this function can be activated via the APP to warm the battery in low-temperature conditions, preventing performance degradation. A temperature control switch in the heating circuit is recommended for secondary protection.
- Alarm Function: If enabled, the BMS will provide external alerts for safety risks like over-temperature, overcharge, or over-discharge.
- Battery Parallel Function: For parallel battery packs, this function (used with parallel modules) ensures synchronized operation.
- Emergency Switch: In critical situations (e.g., over-temperature, over-discharge, overcharge, cell drop), activating the emergency switch via the APP will enable charge and discharge for 30 minutes, providing a temporary operational window.
- Intelligent Sleep: This feature puts the BMS into a low-power standby mode if the charge/discharge current is below 1A for 26 consecutive hours, reducing self-consumption. It can be reactivated by pressing a button or connecting a charger.
- Communication Function (RS485/CAN): If equipped, these interfaces allow for advanced communication with other systems. Address and protocol settings can be configured via the APP.
6.4. Parameter Setting
Detailed instructions for setting all parameters, including advanced configurations, are provided in the dedicated "Instructions for Setting Protection Board Parameters" document, which is part of the full user manual PDF. Users should refer to this document for precise parameter adjustment procedures.
7. Maintenance
To ensure the longevity and reliable performance of your JIKONG BMS, follow these maintenance guidelines:
- Regular Inspection: Periodically check all wiring connections for tightness and signs of corrosion or damage.
- Cleanliness: Keep the BMS unit clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning.
- Temperature Management: Ensure the BMS operates within its specified temperature range (-30°C to 70°C). Adequate ventilation is important, especially in enclosed spaces.
- Firmware Updates: Check the official JIKONG website or APP for any available firmware updates to ensure optimal performance and access to new features.
- Avoid Physical Damage: Protect the BMS from impacts, vibrations, and excessive mechanical stress.
8. Troubleshooting
This section provides guidance on common issues you might encounter with your JIKONG BMS.
| Problem | Possible Cause | Solution |
|---|---|---|
| BMS not powering on/activating | Incorrect wiring; battery voltage too low; activation method not followed. | Verify all wiring (P-, B-, balance wires). Ensure battery voltage is sufficient. Activate by connecting a charger or using the optional button/display. |
| Bluetooth connection issues | APP not installed correctly; incorrect password; Bluetooth module not connected or faulty; out of range. | Ensure APP is installed and updated. Check Bluetooth module connection. Move closer to the BMS. Verify APP password if required. |
| Battery not balancing | Active equalization disabled in APP; trigger voltage difference not met; faulty balance wires. | Enable active equalization in the APP. Adjust trigger voltage difference. Check balance wire connections. |
| Charging/Discharging cuts off unexpectedly | Protection (overcharge, over-discharge, overcurrent, over-temperature) triggered. | Check battery cell voltages, current, and temperature via APP. Review protection parameters in APP and adjust if necessary (within safe limits). Allow conditions to return to normal for recovery. |
| Short circuit protection triggers frequently | High inrush current from charger/load; actual short circuit. | Verify external wiring for actual shorts. Increase short circuit protection delay in APP if high inrush current is the cause (refer to parameter setting guide). |
9. User Tips
- APP Password: If the APP prompts for a password, ensure you are using the correct default password or any custom password you may have set. Refer to the full PDF manual for default credentials if applicable.
- Initial Setup: Take your time during initial wiring. Double-check every connection, especially the balance leads, to prevent damage.
- Parameter Customization: The JIKONG BMS offers extensive parameter customization. Utilize the APP to fine-tune settings like protection thresholds and balancing currents to match your specific battery pack and application needs.
- Temperature Monitoring: Pay close attention to temperature readings, especially during high charge/discharge cycles or in extreme environments. The NTC sensors are crucial for preventing thermal issues.
10. Warranty & Support
For warranty information, technical support, and service inquiries, please contact your retailer or the official JIKONG customer service. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format is available for download, which includes comprehensive parameter settings and advanced configurations. You can access it via the following link: JIKONG BMS User Manual (PDF).