1. Product Overview
The JIKONG V19 Smart BMS (Battery Management System) is an intelligent protection board designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge, over-discharge, over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS and remote functions. This BMS is suitable for various battery types including Lithium Iron Phosphate (LiFePO4), Ternary Lithium (Li-ion), and Lithium Titanate (LTO) batteries.
The protection board utilizes energy transfer active balancing technology with a continuous balance current of 1A or 2A, ensuring battery consistency, extending battery life, and delaying aging. It is compact, easy to operate, and full-featured, making it ideal for small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage, base station backup power supplies, and solar power stations.
The BMS supports a mobile APP for Android and iOS, allowing users to monitor battery status, modify working parameters, and control charge/discharge switches via Bluetooth.

2. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support ACC detection function (Optional)
- Support heating function (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
3. Setup Guide
3.1. Unboxing and Package Contents
Before proceeding with installation, please verify that all components are present and undamaged. The package typically includes:
- BMS unit (with built-in Bluetooth)
- Temperature sensor (40cm)
- Balance Wires (75cm)
- Active Switch (15cm)
- Heating cable (Only for BMS models with Heat Function)
- Screws (x6)
- Pack box

3.2. APP Installation
The JIKONG BMS is managed via a mobile application available for both Android and iOS devices. To install the APP:
- For iOS devices, search for "JIKONG BMS" in the Apple App Store.
- For Android devices, search for "JK BMS" in the Google Play Store. (Android Version 7 minimum is required).
- Alternatively, scan the QR code below to download the APP.

3.3. Hardware Connection and Wiring
The JK-BxA8S-20P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure correct connections to prevent damage.
- Connect the protection board and battery pack according to the wiring diagram provided.
- Ensure that the last power cord (B+) is connected to the main positive pole of the battery.
- The total voltage of the battery pack must be greater than 20V (for default BMS) or 10V (for 4S BMS) before starting up.
- Ensure the balance cable is properly connected.
- Verify that P- and B- are correctly connected.
- Confirm that the protection board is securely fixed to the battery cells.

Interface Definitions:
| Connector | Pin Name | Description |
|---|---|---|
| P1 (Balance & Acquisition) | B- to B8, B+ | Connects to individual cell positives (B1-B8) and total battery positive (B+). B- is total negative. |
| P2 (Buzzer, Optional) | GND, VCC | Buzzer power negative and positive. |
| P3 (Communication, Optional) | CAN L, CAN H, RS485 A, RS485 B | CAN signal negative/positive, RS485 signal positive/negative. |
| P4 (GPS) | GND, RX, TX, VGPS | Power/signal ground, UART RX/TX, GPS power output. |
| P5 (External Temp Sensors) | T5A, T5B, T4A, T4B | Pins for 4th and 5th external temperature sensors. |
| P6 (Internal Temp Sensors) | T2A, T2B, T1A, T1B | Pins for 1st and 2nd internal temperature sensors. |
| P7 (Display) | VCC, A, B, GND, K+, K- | Display power output, RS485 signals, ground, activation signals. |
| P8 (Parallel, Optional) | P-status, P-EN | Parallel module status signal and enable signal. |
| P9 (ACC) | ACC+, ACC-, NC, C_Detect+, C_Detect- | ACC positive/negative, Not Connected, Charger output 12V positive/negative. |
| Heating Wire (Optional) | HT- | Heater element negative electrode. |
3.4. Device Activation
The BMS does not have a power-on control switch. It is designed for charging activation mode. After the battery assembly is complete, the charger needs to be connected to activate the protection board.
To activate the BMS:
- Connect the charger to the battery pack. The charger voltage must be at least 2V higher than the battery pack voltage.
- Alternatively, use the display activation button or an additional switch (if equipped) to activate the BMS. Users with a display screen and button can simply insert the cable into the display interface and press the button.
4. Operating Instructions
4.1. APP Operation
The mobile APP allows real-time monitoring and parameter configuration of your BMS. After installing the APP and activating the device:
- Turn on GPS and Bluetooth on your mobile phone.
- Open the APP, click on the top left corner to search for devices.
- Select your device from the list to connect. The default password is "1234".
- For the first startup, set the number of units (battery strings) and battery type (LiFePO4, Li-ion, LTO) in the parameter settings. The default parameter setting password is "123456".
- Go back to the real-time status page to check the battery status. Ensure no error messages are prompted and normal operation is indicated. The APP will show the highest voltage in blue and the lowest voltage in red.

4.2. Active Equalization
The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring balanced cell voltages. Before using this function, set the basic battery parameters in the APP, including the number of cells, battery capacity, and trigger equalization differential pressure (default value can be retained). The default balance current is 1A/2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. If not needed, the balancing switch can be turned off in the APP's BMS control page.
4.3. Heating Function (Optional)
For BMS models with the heating function ("Heat" in the model name), this feature prevents charging/discharging issues in low temperatures. The heating interface requires an external heating film or charger. The green 5PIN cable of the heating cable connects to the heating pad, while the red and black cables connect to the smart charger. The maximum heating power is 200W (100W for B2A8S20P) with a maximum current of 3A and voltage of 100V. It is recommended to use a normally closed temperature control switch (45°C to 65°C) in series with the heating circuit as a secondary protection.
Heating is activated when the battery temperature falls below the low-temperature protection threshold for charging. The APP can also activate heating, which will consume battery power. Heating via the charger is also possible, depending on the BMS hardware and charger.
4.4. Battery Parallel Function (Optional)
For models supporting battery parallel function, this feature requires synchronous use with parallel modules. Ensure to disable the "charging current limiting" function in the APP when using this feature.
4.5. ACC Detection Function (Optional)
This function enables discharge. It can be achieved by applying a voltage between 20V-100V to ACC+ and ACC-, or by directly short-circuiting ACC+ and ACC-. Additionally, the C_detect+ and C_detect- interfaces are reserved for charger detection, connecting to the 12V voltage signal output of the charger to enable charging.
4.6. Communication Functions (Optional)
The BMS supports optional CAN and RS485 communication functions. Users can select CAN or RS485 for multiplexed ports on the APP's BMS control page. Address and communication protocol can be configured via the APP. Refer to the Jikong Protection Board communication protocol document for specific details.
5. Maintenance
The JIKONG Smart BMS is designed for durability and reliability. Regular maintenance involves monitoring its performance through the mobile APP and ensuring all connections remain secure.
- Regular Monitoring: Periodically check the battery status, cell voltages, current, and temperature readings via the mobile APP to ensure optimal performance and detect any anomalies early.
- Connection Integrity: Ensure all wiring, especially the balance wires and main power connections (P- and B-), are tight and free from corrosion. Loose connections can lead to inaccurate readings or system malfunctions.
- Software Updates: Keep the mobile APP updated to the latest version to benefit from new features, improvements, and bug fixes.
- Environmental Conditions: Operate the BMS within its specified temperature range (-30°C to 70°C) to prevent damage and ensure longevity. If operating in extremely cold conditions, utilize the heating function (if available) to protect the battery cells.
6. Troubleshooting
6.1. Common Issues and Solutions
- BMS Does Not Turn On:
- Ensure the last "B+" line of the balance cable is connected to the positive pole of the battery.
- Activate the BMS by connecting the charger. The charger voltage must be greater than 4V above the battery pack voltage.
- Verify that the charger has voltage output.
- Inaccurate Voltage Readings:
- Measure the actual total voltage of the battery pack using a multimeter.
- Enter this actual total voltage into the "voltage calibration" setting within the APP's parameter page.
- Inaccurate Current Readings:
- Ensure both B- and P- (7AWG wires) are connected in parallel; otherwise, it will lead to current errors.
- Measure the actual current of the battery pack with a clamp meter.
- Enter this actual current into the "current calibration" setting in the APP. Higher actual current during calibration leads to higher accuracy.
- Inaccurate Capacity Readings:
- The initial capacity estimated by the monomer voltage when the BMS is first powered on may be inaccurate.
- Calibrate the capacity by fully discharging the battery pack to its cut-off voltage, then fully charging it without interruption.
- Inconsistent String Number:
- Check if the "unit quantity" in the APP's parameter settings is correctly configured for your battery pack.
- If there is no voltage in two or more strings in the middle of the pack, inspect the acquisition cable for disconnections.
6.2. Protection Triggers and Recovery
The BMS is equipped with various protection mechanisms. When a protection is triggered, the BMS will take action (e.g., stop charging/discharging) and will recover once conditions return to normal or after a set delay.
- Overcharge Protection: Stops charging when any cell voltage exceeds the set limit. Recovers when all cell voltages drop below the recovery threshold.
- Discharge Undervoltage Protection: Stops discharging when any cell voltage falls below the set limit. Recovers when all cell voltages rise above the recovery threshold. An automatic shutdown voltage is also configurable.
- Overcurrent Protection (Charge/Discharge): Stops charging/discharging if current exceeds the set limit for a specified delay. Recovers after a set release time. (Max continuous discharge current is 200A).
- Overtemperature Protection (Charge/Discharge): Stops charging/discharging if temperature exceeds the set limit. Recovers when temperature falls below the recovery threshold.
- Low Temperature Protection (Charge): Stops charging if temperature falls below the set limit. Recovers when temperature rises above the recovery threshold.
- Short Circuit Protection: Automatically triggers upon short circuit. Recovery time and delay can be adjusted in the APP. Issues may arise from high peak currents from chargers or large load capacitances.
- Emergency Switch: In critical situations (over-temperature, over-discharge, over-charge, string drop), activating the emergency switch in the APP will enable charge and discharge for 30 minutes, providing an emergency use period.
7. Specifications
7.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 7.5-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 8 | String |
| Maximum Balancing Current | 1 or 2 | A |
| Maximum Charging Current | 200 | A |
| Maximum Discharge Current | 200 | A |
| Maximum Instantaneous Current | 400 | A |
| Maximum Internal Loop Resistance | 0.35 | mΩ |
| Protective Plate Size | 152.25 × 127.26 × 15.6 | mm |
| Finished Weight | 424 | g |


7.2. Default Parameters
The BMS comes with pre-configured default parameters for various battery types (Li-ion, LiFePO4, LTO). These can be adjusted via the APP as needed.
| Parameter | Li-ion Default | LiFePO4 Default | LTO Default | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 1 or 2 | 1 or 2 | 1 or 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | uS |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
7.3. Dimensions

8. User Tips
- Voltage Compatibility: The JIKONG BMS is designed to be compatible with battery packs ranging from 4S to 8S, supporting operating voltages from 12V to 36V. Ensure your battery configuration matches the BMS's supported string count.
- First-Time Setup: When setting up for the first time, always double-check all wiring connections before powering on. Incorrect wiring can lead to damage.
- APP Password: Remember the default APP connection password "1234" and the parameter setting password "123456" for initial setup. Change them if necessary for security.
- Heating Cable Connection: For models with heating functionality, ensure the green 5PIN heating cable is correctly linked to the heating pad, and the red/black cables are connected to a smart charger for proper temperature-controlled heating.
- Capacity Calibration: For accurate capacity readings, perform a full discharge to cut-off voltage followed by an uninterrupted full charge after initial setup.
9. Support and Documentation
For further detailed information and technical documentation, please refer to the official user manual PDF:
JIKONG Lithium Battery Active Balance Protection Board Maintenance Manual (PDF)
Manufacturer: Chengdu Jikong Technology Co.LTD