1. Introduction
The JIKONG Smart Active Battery Management System (BMS) is a sophisticated management system designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and GPS remote capabilities.
This BMS is suitable for various battery types, including Lithium Iron Phosphate (LiFePo4), Ternary Lithium (Li-Ion), and Lithium Titanate (LTO) batteries. It is engineered to ensure battery consistency, extend battery life, and prevent premature aging through its advanced active balancing technology.
The protection board utilizes energy transfer active balancing technology, capable of achieving a continuous balance current of up to 0.6A. This high-current active balancing maximizes battery consistency, improves battery range, and delays battery aging.
The compact design, ease of operation, and comprehensive functionality make this protection board ideal for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.


2. Specifications
The JIKONG BMS offers robust features and performance. Key specifications are detailed below:
2.1. General Product Properties
- Brand Name: JIKONG
- Type: LiFePO4 Battery BMS
- Handware or Smart: SMART BMS
- Usage Scenario: Power BMS
- Certification: CE, FCC, RoHS
- High-concerned chemical: None
2.2. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support alarm function (Optional)
- Support parallel function (Optional)
- ACC detection function (Optional)
- Support heating function (Optional)
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection

2.3. Main Parameters (JK-BD6A20S20P)
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 20-100 | V |
| Operating power consumption | <800 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 24 | String |
| Maximum balancing current | 0.6 | A |
| Maximum charging current | 200 | A |
| Maximum discharge current | 200 | A |
| Maximum instantaneous current | 400 | A |
| Maximum internal loop resistance | 0.35 | mΩ |
| Protective plate size (L*W*H) | 162*102*20.4 | mm |
| Finished weight | 567 | g |


3. Setup and Installation
3.1. Packing List
Before installation, please verify that all components are present in the package:
- BMS * 1
- NTC * 1 (long 400mm)
- Balance Wires * 1 (750mm)
- Switch * 1 (500mm)
- Packing box * 1

3.2. Wiring and Connections
The JK-BD6AXXS-10P/12P/15P/20P series protection board is compatible with lithium battery packs ranging from 7 to 24 series. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure correct connections to prevent damage.
General Wiring Steps:
- Connect the main negative terminal (B-) of the BMS to the total negative terminal of the battery pack.
- Connect the balance wires (B1, B2, B3... B24) to their respective positive terminals of each cell in the battery pack. Ensure the order is correct, starting from B1 (first cell positive) up to B24 (24th cell positive).
- Connect the main positive terminal (P-) of the BMS to the external load or charger negative terminal.
- If using the heating function, connect the protection board heating wire and temperature control switch as shown in the wiring diagram.
- Connect the NTC temperature sensor to the designated NTC interface on the BMS.
- Connect the switch to the designated switch interface.
- For communication (RS485, CAN) or display interfaces, connect the respective modules as needed.

3.3. Interface Definition
The BMS features a rich interface to accommodate various communication and control needs:

Connector P1 (XH-15AW - Balance with Acquisition interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive |
| ... | ... | ... |
| 24 | B24 | The twenty-fourth battery positive (Total battery positive) |
| 11 (B+) | B+ | Protection board power supply, connected to the battery |
Connector P3 (XH-4AW - Temperature interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B |
| 3 | T2A | Second temperature sensor pin A |
| 4 | T2B | Second temperature sensor pin B |
Connector P4 (A1254WF-4A - Communication interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | RS485 B | RS485 signal negative terminal |
| 2 | RS485 A | RS485 signal positive terminal |
| 3 | CAN H | CAN signal positive terminal |
| 4 | CAN L | CAN signal negative terminal |
Connector P5 (1.25T-4PWT - GPS interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | VGPS | Power output, voltage close to B+ |
| 2 | TX | UART_TX, 3.3V |
| 3 | RX | UART_RX, 3.3V |
| 4 | GND | Power/signal ground |
Connector P6 (A1254WF-6A - Display interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | VCC | Display power output |
| 2 | A | Display RS485 signal positive |
| 3 | B | Display RS485 signal negative |
| 4 | GND | Negative terminal |
| 5 | K+ | Activate the positive signal |
| 6 | K- | Activation signal negative electrode |
Connector P7 (A1254WF-3A - Parallel interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | GND | Signal ground |
| 2 | P-EN | Parallel module enable signal (low level to turn on parallel module) |
| 3 | P-status | Parallel module status signal |
Connector P8 (A1254WF-2A - Alarm interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | VCC | Alarm power supply positive |
| 2 | GND | Alarm power negative |
Connector P9 (A1254WF-5A - ACC Optional interface):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | ACC+ | ACC Positive |
| 2 | ACC- | ACC Negative |
| 3 | NC | Not connected (Empty) |
| 4 | C_Detect+ | Charger output 12V positive |
| 5 | C_Detect- | Charger output 12V negative |
Connector D1 (Heating wire - 16AWG-Orange-15CM Optional):
| Pin No. | Name | Definition |
|---|---|---|
| 1 | HT- | Heater element negative electrode |
3.4. Device Activation
Before powering on the protection board, double-check that the balance cable is properly connected and that the P- and B- terminals are correctly connected. Ensure the protection board is securely fixed to the battery core. Incorrect connections can lead to abnormal operation or even damage.
The protection board does not have a physical power-on switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After the battery assembly is complete, connect the charger to activate the protection board.
Alternatively, the protection board supports key activation and display activation. If you have chosen a display screen and button, simply insert the cable into the display interface and press the button to activate the BMS.
4. Operation
4.1. APP Installation and Connection
The JIKONG BMS comes with a mobile APP compatible with Android and iOS operating systems. The APP allows you to monitor the battery's working status, modify parameters, and control charge/discharge switches.
To install the APP, scan the QR code below. An Android device requires Android Version 7 or higher.

The APP connects to the protection board via Bluetooth. Once connected, you can view real-time battery information and adjust settings.
4.2. Active Equalization
The BMS employs active equalization to transfer energy from higher-voltage cells to lower-voltage cells, ensuring voltage balance with minimal energy loss. Before using this function, set the basic battery parameters in the APP, including the number of cells, battery capacity, and trigger equalization differential pressure (default value can be retained).
You can set the balance trigger pressure difference (mV) in the APP's parameter settings. When balancing is enabled, it automatically activates if the voltage difference between any two battery strings exceeds the set value, and deactivates when the difference falls below the set value. The default balance current is 0.6A. You can adjust this current based on your battery capacity, but it's recommended not to exceed 0.2C of the battery capacity. If not needed, the balancing function can be turned off in the BMS control page of the APP.

4.3. Parameter Setting
Detailed parameter settings can be found within the APP. This includes configuring various protection thresholds, communication protocols, and operational modes. Refer to the 'Instructions for Setting Protection Board Parameters' within the APP for comprehensive guidance.
4.4. Optional Functions
The BMS supports several optional functions that can be configured via the APP or external modules:
- GPS and Display Interface: The BMS reserves a GPS port for location tracking and a display interface for connecting an external display to view battery information.
- Heating Function: For low-temperature environments, an optional heating function can be used with a resistance heater or heating film to warm the battery, preventing performance degradation. The heating current is 10A. It's recommended to use a temperature control switch (45°C to 65°C normally closed) as a secondary safety measure.
- Battery Parallel Function: Supports parallel connection of battery packs, requiring synchronous use with parallel modules and disabling the 'charging current limiting' function in the APP.
- ACC Detection Function: Can be used to enable discharge. This can be achieved by applying 12V-70V between ACC+ and ACC- or by directly short-circuiting them. A charger detection function is also available via C_detect+ and C_detect- interfaces.
- Communication Function (CAN/RS485): Supports optional CAN and RS485 communication. Users can select the desired protocol and configure the address and communication protocol via the APP.
5. Maintenance
Proper maintenance ensures the longevity and optimal performance of your JIKONG BMS and battery pack.
5.1. Intelligent Sleep Function
The BMS features an intelligent sleep function to reduce its own energy consumption when the battery pack is in standby (charging and discharging current less than 1A for 26 consecutive hours). This helps preserve battery energy. The BMS can be reactivated by pressing a button (if equipped) or by connecting a charger.
5.2. General Care
- Regularly check all wiring connections for tightness and integrity. Loose connections can lead to poor performance or damage.
- Keep the BMS unit clean and free from dust and moisture.
- Ensure adequate ventilation around the BMS, especially if it's enclosed, to facilitate heat dissipation. The aluminum alloy casing provides superior heat dissipation.
- Monitor battery parameters via the APP periodically to ensure all cells are balanced and operating within safe limits.

6. Troubleshooting and Protection Mechanisms
The JIKONG BMS is equipped with multiple protection features to safeguard your battery pack. Understanding these mechanisms can help in basic troubleshooting.
6.1. Overvoltage Protection and Recovery (Charge)
The BMS includes standard charge overvoltage protection. If any battery cell's voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the set overcharge recovery voltage.
6.2. Undervoltage Protection and Recovery (Discharge)
Standard discharge undervoltage protection is integrated. If any cell's voltage falls below the set undervoltage protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the set undervoltage recovery voltage. If any cell voltage drops below the automatic shutdown voltage, the BMS will shut down completely.
6.3. Overcurrent Protection and Recovery (Charge/Discharge)
The BMS features standard charge and discharge overcurrent protection. If the current exceeds the set continuous current for a specified delay time, the BMS will trigger protection and stop the operation. The operation resumes after the overcurrent release time has passed.
6.4. Overtemperature/Low Temperature Protection and Recovery
The BMS provides standard charge and discharge overtemperature protection, as well as charge low temperature protection. If the temperature exceeds or falls below the set thresholds, the BMS will stop the respective operation. The operation resumes once the temperature returns to within the safe operating range.
6.5. Short Circuit Protection and Recovery
Standard short circuit protection is included. The BMS will automatically trigger protection if a short circuit is detected. The protection will be lifted after a set recovery time. If a short circuit occurs when connecting a charger or load, increasing the short circuit delay time in the APP settings might resolve issues caused by instantaneous peak currents.
6.6. Emergency Switch
In case of critical issues like over-temperature, over-discharge, over-charge, or cell drop, activating the emergency switch in the BMS control page of the APP will enable charge and discharge for 30 minutes. This provides a temporary operational window to address the issue, even if a single cell voltage reaches the automatic shutdown level.
7. Warranty and Support
7.1. Service Commitment
JIKONG provides global warranty services for its products. The warranty covers quality issues not caused by human factors (including functional failures, component defects, etc.) for three years from the date of receipt of the goods. The service form includes support for free repair or replacement, depending on the product's repairability evaluation results.
7.2. After-Sales Process
- Customer Application: Customers submit applications through official after-sales channels (email/online customer service), providing order numbers, fault descriptions, and evidence (photos/videos).
- Return of Goods: The customer is responsible for the international logistics cost of sending the product back to China and provides the waybill number for tracking purposes.
- Packaging Requirements: Ensure that the product accessories are complete and the packaging is intact to avoid transportation damage.
- Detection and Processing: After receiving the product, the quality department will complete the inspection and inform the repair/replacement plan within 5-7 working days. Responsibility definition: Non-human damage qualifies for free repair/replacement, with the seller bearing the return international logistics costs.
- Return and Tracking: After the repair/replacement passes the quality inspection, it will be sent back to the customer through logistics, and full logistics tracking information will be provided throughout the process. Time commitment: The return logistics cycle is controlled within 7-15 working days (may fluctuate due to customs clearance and other factors). Cross-border compliance: Customers need to cooperate in providing necessary customs declaration documents (such as original purchase vouchers, repair statements) to avoid customs clearance delays.

8. User Tips
- Always perform a thorough visual inspection of all connections before applying power to the BMS.
- For optimal battery life, regularly check the cell balance via the mobile APP. Adjust the active balancing parameters if significant discrepancies are observed.
- In cold climates, consider utilizing the optional heating function to maintain battery performance and prevent damage from low temperatures.
- Familiarize yourself with the APP's parameter settings to customize protection thresholds according to your specific battery chemistry and application needs.
- If experiencing frequent short-circuit protection trips during charger or load connection, try increasing the short circuit delay time in the APP settings to accommodate initial current surges.