1. Introduction
The Hantek HT824 Multifunction Process Calibrator is a high-accuracy, high-stability instrument designed for a wide range of industrial and laboratory applications. It can simulate and measure various electrical signals, including millivolt and volt voltages, milliampere currents, and different types of thermocouple (TC) and Resistance Temperature Detector (RTD) signals. This manual provides essential information for the safe and effective use of your calibrator.
2. Package Contents
Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your supplier.
Figure 2.1: Hantek HT824 Calibrator and included accessories.
- Chassis (Main Unit)
- Data Line (USB Cable)
- Test Leads
- Chassis Key
- Thermocouple
- Instructions Manual
- CD (Software/Drivers)
- Power Cord
3. Product Overview
The Hantek HT824 features a clear 5 1/2 digit input/output display and an intuitive keypad for operation. Below are images illustrating the device from various angles.
4. Specifications
The following tables detail the technical specifications of the Hantek HT824 Multifunction Process Calibrator.
4.1 DC Voltage Measurement
| Parameter | Range (Upper Screen)*1 | Range (Bottom Screen)*2 | Range |
|---|---|---|---|
| Range | 0-30.000V | 0-24.000V | 0-90.000mV |
| Resolution | 0.001V | 0.001V | 0.001mV |
| Accuracy | 0.1%+5 | 0.05%+5 | 0.05%+5 |
*1 and *2: Input resistance is greater than 1MΩ
4.2 DC Voltage Output
| Parameter | Range | Range |
|---|---|---|
| Range | 0—20.000V | 0—90.000mV |
| Resolution | 0.001V | 0.001mV |
| Accuracy | 0.05%+5 | 0.05%+5 |
4.3 Millivolt Measurement and Output
| Parameter | Value |
|---|---|
| Range | -10.000mV—80.000mV |
| Resolution | 0.001mV |
| Accuracy | 0.05%+5 |
*1 Press TC(16) to select this function. Signal is at thermocouple micro input/output TC port.
4.4 DC Current (Milliampere) Measurement
| Parameter | Range (Upper Screen)*1 | Range (Bottom Screen)*2 |
|---|---|---|
| Range | 0—24.000mA | 0—24.000mA |
| Resolution | 0.001mA | 0.001mA |
| Accuracy | 0.05%+5 | 0.05%+5 |
4.5 DC Current (Milliampere) Output
| Parameter | Value |
|---|---|
| Range | 0—24.000mA |
| Resolution | 0.001mA |
| Accuracy | 0.05%+5 |
SIMU (Simulation): When outputting current, external voltage is greater than 12V, less than 28V.
SOUR (Source): When outputting current, signal driving ability is 1000Ω in 20mA.
4.6 Resistance Measurement
| Parameter | Range 1 | Range 2 |
|---|---|---|
| Ohm Range | 0—400.00Ω | 400.0—4000.0Ω |
| Accuracy ±Ω (4 Wire) | 0.02%+5 | 0.02%+5 |
| Accuracy ±Ω (2 & 3 Wire) | 0.05%+5 | 0.05%+5 |
- Excitation current: 0.2mA.
- Maximum input voltage: 30V.
- 2 Wire: Do not include wire resistance.
- 3 Wire: Assume to use the matched testing wire, the total resistance cannot be greater than 100Ω.
4.7 Resistance Output
| Parameter | Range 1 | Range 2 |
|---|---|---|
| Range | 5.00Ω—400.00Ω | 400.0—1500.0Ω |
| Excitation current from the measurement instrument | 0.15mA-2mA | 0.05mA-0.8mA |
| Accuracy ±Ω | 0.05%+5 | 0.05%+5 |
| Resolution | 0.1Ω | 0.1Ω |
4.8 Temperature - Thermocouple (ITS-90)
| Type | Range | Resolution | Measurement and Output Accuracy ±℃ |
|---|---|---|---|
| S | -50.0℃ to 0℃ | 0.1℃/0.1℉ | 2℃ |
| 0℃ to 500.0℃ | 0.1℃/0.1℉ | 1.5℃ | |
| 500.0℃ to 1760.0℃ | 0.1℃/0.1℉ | 1.3℃ | |
| R | -50.0℃ to 0℃ | 0.1℃/0.1℉ | 2℃ |
| 0℃ to 500.0℃ | 0.1℃/0.1℉ | 1.5℃ | |
| 500.0℃ to 1760.0℃ | 0.1℃/0.1℉ | 1.3℃ | |
| B | 200℃ to 800℃ | 1℃/1℉ | 2.5℃ |
| 800℃ to 1800℃ | 1℃/1℉ | 2.3℃ | |
| K | -200.0℃ to 1370.0℃ | 0.1℃/0.1℉ | 1.3℃ |
| N | -200.0℃ to 1300.0℃ | 0.1℃/0.1℉ | 1.3℃ |
| E | -200.0℃ to 1000.0℃ | 0.1℃/0.1℉ | 1℃ |
| J | -200.0℃ to 1200.0℃ | 0.1℃/0.1℉ | 1℃ |
| T | -200.0℃ to 400.0℃ | 0.1℃/0.1℉ | 1℃ |
If open cold junction compensation, there should be additional ±0.5℃.
4.9 Temperature - Thermal Resistance
| Type | Range | Accuracy ±℃ (Testing 4 wire ℃) | Accuracy ±℃ (Testing 2 & 3 wire ℃) | Output ℃ |
|---|---|---|---|---|
| Pt100-385 | -200.0℃-850.0℃ | 0.8℃ | 1℃ | 0.8℃ |
| Pt100-3926 | -200.0℃-850.0℃ | 0.8℃ | 1℃ | 0.8℃ |
| Pt100-JIS | -200.0℃-850.0℃ | 0.8℃ | 1℃ | 0.8℃ |
| Pt200-385 | -200.0℃-250.0℃ | 0.7℃ | 0.8℃ | 0.7℃ |
| 250.0℃-630.0℃ | 1.3℃ | 2.1℃ | 1.3℃ | |
| Pt500-385 | -200.0℃-500.0℃ | 0.8℃ | 1.1℃ | 0.8℃ |
| 500.0℃—630.0℃ | 1℃ | 1.5℃ | 1℃ | |
| Pt1000-385 | -200.0℃-100.0℃ | 0.7℃ | 0.7℃ | 0.8℃ |
| 100.0℃-630.0℃ | 0.7℃ | 0.8℃ | 0.8℃ | |
| Cu100 | -50.0℃-150.0℃ | 1℃ | 1.2℃ | 1℃ |
| Cu50 | -50.0℃-150.0℃ | 1℃ | 1.2℃ | 1℃ |
- Resolution: 0.1°C, 0.1°F
- Allowable excitation current (output): Pt100-385, Pt100-392, Pt100-JIS, Pt200-385: 0.15 to 3.0 mA
- Pt500-385: 0.05 to 0.80mA; Pt1000-385: 0.05 to 0.40mA
- 2 Wire: Do not include wire resistance.
- 3 Wire: Assume to use the matched testing wire, the total resistance cannot be greater than 100Ω.
4.10 Comprehensive Index
| Parameter | Value |
|---|---|
| Operation Temperature | 0℃ to 50℃ |
| Storage Temperature | -20℃ to 70℃ |
| Operation Height | Average elevation 3000 meters below. |
| Relative Humidity (No condensation) | 75% (30℃ to 40℃) |
| 45% (40℃ to 50℃) | |
| 35% (50℃ to 55℃) | |
| <10℃, no control | |
| Stability | Out of the range 23±5℃, each degree increase ±0.005% of the range. |
| Vibration | The random vibration, 2g, 5 to 500Hz |
| Security | EN 61010-1:1992 |
| Protection Level | Pollution grade Ⅱ |
5. Initial Setup
- Unpacking and Inspection: Carefully remove the calibrator and all accessories from the packaging. Inspect for any signs of damage.
- Charging the Battery: The HT824 uses an advanced built-in 7.4V/7800mAh lithium battery. Connect the provided power cord to the calibrator and a suitable power outlet to charge the device before first use.
- Software Installation (Optional): Insert the provided CD into your computer to install any necessary software or drivers for PC connectivity and data analysis.
- Power On: Press the power button to turn on the calibrator. The display will illuminate.
6. Operation
The HT824 offers a variety of measurement and output functions. The screen displays connection diagrams for probes and plugs to help prevent incorrect operation.
6.1 General Operation Features
- Display: 5 1/2 digit input/output display for precise readings.
- Cold Junction Compensation: Supports manual and automatic cold junction compensation for thermocouple measurements.
- Direct Temperature: The calibrator can directly measure and output temperature values.
- Signal Output: Features auto triangular wave and step wave signal output.
- Data Storage: Capable of storing 8 sets of measurement and output data, which can be recalled for review.
- Memory Function: All setting values and the function from the last operation are automatically saved after power-off.
- Backlight: The display includes a backlight for visibility in various lighting conditions.
- Step/Slope Output: The output function includes manual/auto step and slope output, allowing arbitrary setting of 0%, 25%, and 100% values within the signal output range to test transmitter response speed.
6.2 Measurement and Output Modes
The calibrator supports various measurement and output modes. The following images illustrate the software interface for different functions:
Refer to the on-screen prompts and the detailed instructions in the full user manual (PDF) for specific steps on selecting modes, connecting probes, and interpreting results.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the calibrator. Do not use abrasive cleaners or solvents.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will be stored for an extended period.
- Storage: Store the calibrator in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection during storage and transport.
- Calibration: For continued accuracy, periodic calibration by a qualified service center is recommended.
8. Troubleshooting
- Device Not Powering On: Ensure the battery is charged. Connect the power adapter and try again. If the issue persists, the battery may need replacement or there could be an internal fault.
- Inaccurate Readings: Check that the correct measurement mode is selected and that probes are properly connected. Ensure the device is within its specified operating temperature and humidity ranges. For temperature measurements, verify cold junction compensation settings.
- No Signal Output: Confirm the output mode is correctly configured and the output range is appropriate for the connected device. Check all connections.
- PC Connection Issues: Ensure the USB data line is securely connected and that the necessary drivers from the provided CD are installed on your computer.
9. User Tips
- The advanced built-in battery management system and 7.4V/7800mAh lithium battery are designed to provide over 8 hours of continuous operation, making it reliable for extended on-site measurement tasks.
- Always pay attention to the connection diagrams displayed on the screen when connecting probes and plugs to avoid incorrect operation and potential damage to the device or the circuit being tested.
- Utilize the data storage feature to save up to 8 sets of measurement and output data for later review or analysis, which can be particularly useful for repetitive tasks or trend monitoring.
10. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please refer to the official Hantek documentation or contact your point of purchase.