A-BF RX-300, RX-350

Contents

A-BF RX-300/RX-350 Thermal Imager User Manual

Models: RX-300, RX-350

Introduction

This manual provides detailed instructions for the safe and effective use of your A-BF RX-300 and RX-350 Thermal Imagers. These devices are designed for various applications including electrical inspection, electronic parts repair, microcircuit detection, and general facility maintenance. Please read this manual thoroughly before operating the device.

Safety Information

Always observe the following safety precautions to prevent injury and damage to the device:

  • Do not point the laser directly at eyes or reflective surfaces.
  • Do not expose the device to extreme temperatures, humidity, or corrosive environments.
  • Avoid dropping the device. The RX-300/RX-350 models are designed with a 2m drop resistance, but excessive impact can still cause damage.
  • Only use the provided USB-C cable and power adapter for charging.
  • Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.

Package Contents

Upon opening your A-BF Thermal Imager package, please verify that all items are present:

  • A-BF Thermal Imager (RX-300 or RX-350 model)
  • Instruction Manual
  • USB Type-C Charging Cable
  • Power Adapter
  • Lanyard
  • Storage Bag/Carrying Case
A-BF RX-300 with accessories
Figure 1: A-BF RX-300 Thermal Imager and included accessories (Instructions, packing box, lanyard, USB-TypeC cable, storage bag).
RX-300 thermal imager and accessories inside carrying case
Figure 2: The RX-300 thermal imager, manual, USB-C cable, and power adapter neatly stored inside its carrying case.

Setup

1. Charging the Device

Before first use, fully charge the thermal imager. Connect the provided USB Type-C cable to the device's charging port and the other end to the power adapter. Plug the adapter into a wall outlet. The charging indicator on the screen will show the charging status.

USB Type-C charging port on the thermal imager
Figure 3: USB Type-C charging port location on the device.
Thermal imager connected to laptop for charging and data transfer
Figure 4: The thermal imager connected via USB-C, showing charging status and PC software interface.

2. Power On/Off

Press and hold the power button (usually marked with a power symbol) located on the device to turn it on or off.

3. Basic Controls

The device features an intuitive button layout for navigation and settings adjustment:

  • OK/Enter Button: Confirms selections.
  • Navigation Buttons (Up/Down/Left/Right): Used to navigate menus and adjust settings.
  • Menu Button: Accesses the main menu for settings and modes.
  • Power Button: Turns the device on/off.
  • Trigger Button: (If applicable) Used to capture images or activate laser positioning.
Close-up of the RX-300's control buttons and screen
Figure 5: Close-up view of the RX-300's 2.0" LCD screen and control buttons.

4. Tripod Mounting

The device includes a standard tripod interface at the bottom for stable, hands-free operation, especially useful for long-term monitoring or precise measurements.

Tripod interface on the thermal imager
Figure 6: Tripod interface located at the base of the thermal imager.

Operating Instructions

1. Screen Elements Explanation (RX-300)

The LCD screen displays critical information during operation:

Explanation of RX-300 screen elements
Figure 7: RX-300 Screen Elements Explanation and Color Palette Description.
  1. Emissivity
  2. Battery level
  3. The highest temperature cursor
  4. Color code
  5. Central point temperature cursor
  6. Date
  7. Time
  8. The lowest temperature cursor
  9. Central temperature

Note: The radiation coefficient (emissivity) can be adjusted to increase the measurement accuracy of objects with half-reflection surfaces. The highest and lowest temperature cursors guide users to areas of interest.

2. Color Palette Selection

The thermal imager offers various color palettes to visualize temperature differences. You can select the most suitable palette for your application from the menu.

RX-350 Color Palette options
Figure 8: RX-350 Color Palette options including Rainbow, Iron oxide red, Cold color, Black & white, White & black, and Visible light camera modes.

Available palettes typically include: Iron red, Rainbow, White hot, Black hot, Brown, Blue red, Hot cold, Feather.

3. Image Modes

The device supports different image modes to suit various inspection needs:

  • Infrared Light Mode: Displays only the thermal image.
  • Visible Light Mode: Displays a standard visual image (RX-350).
  • Dual Light Fusion Mode: Overlays the thermal image onto the visible light image for enhanced detail and context (RX-350).

4. Temperature Measurement and Analysis

  • Point Analysis: The central point cursor provides a temperature reading for the center of the screen.
  • High and Low Temperature Detection: The device can automatically identify and display the highest and lowest temperatures within the observed area.
  • Measurement Correction: Adjust emissivity, reflected temperature, and ambient temperature settings for more accurate readings.

5. PC Software Functions

Connect your thermal imager to a computer via USB to utilize the PC software for advanced analysis and reporting. The software supports:

  • Real-time analysis of thermal data.
  • Image data analysis.
  • PDF export of reports.
Real-time analysis of thermal data on a laptop
Figure 9: Real-time analysis of thermal data on a laptop connected to the thermal imager.
PC Software Functions for thermal imager
Figure 10: PC Software Functions, showing support for PDF export and analysis of image data.

6. Applications

The A-BF thermal imagers are versatile tools for various professional and DIY applications:

  • Electrical Inspection: Detecting hot spots in distribution boards, circuit breakers, and wiring to prevent failures.
  • HVAC & Building Diagnostics: Identifying insulation deficiencies, air leaks, moisture issues, and floor heating problems.
  • Electronic Device Detection: Pinpointing overheating components in electronic circuits.
  • Mechanical Overhaul: Monitoring temperature of mechanical parts for wear and tear.
  • Motor Fault Detection: Checking motor temperatures for signs of malfunction.
  • Pipeline Fault Check: Locating blockages or leaks in pipes.
Various applications of the thermal imager
Figure 11: Examples of thermal imager applications: Distribution inspection, circuit power failure detection, floor heating installation detection, and pipeline fault check.
Wider range of thermal imager applications
Figure 12: Additional applications including electronic device detection, mechanical overhaul, research on architectural defects, motor fault detection, detection of floor heating equipment, and distribution box detection.

Maintenance

1. Cleaning

  • Use a soft, damp cloth to clean the exterior of the device.
  • For the lens, use a specialized lens cleaning cloth and solution to avoid scratching.
  • Do not use abrasive cleaners or solvents.

2. Storage

  • Store the device in its protective carrying case when not in use.
  • Keep the device in a dry environment with a storage ambient temperature between -40°C to +70°C (-40°F to +158°F).
  • Avoid prolonged exposure to direct sunlight or extreme temperatures.
  • For long-term storage, ensure the battery is partially charged (around 50%) and recharge it every few months to maintain battery health.

Troubleshooting

If you encounter issues with your thermal imager, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Device does not power onLow battery; device malfunctionCharge the battery fully. If problem persists, contact support.
Inaccurate temperature readingsIncorrect emissivity setting; environmental factorsAdjust emissivity based on the material being measured. Ensure ambient temperature is within operating range.
Screen is blank or frozenSoftware glitch; low batteryPerform a soft reset by holding the power button for 10 seconds. Charge the device.
Cannot connect to PC softwareIncorrect cable; driver issues; software not installedEnsure using original USB-C cable. Install necessary drivers and PC software. Try a different USB port.

Specifications

Below are the detailed specifications for the A-BF RX-300 and RX-350 thermal imagers. For a comprehensive comparison with other models, please refer to Figure 13.

A-BF RX-300 Specifications:

  • IR Resolution: 96x96 pixels (192x192 ISR Function)
  • Image Frame Rate: 25Hz
  • Field of View (FOV): 50°x 50°
  • Minimum Focusing Distance: 0.5m
  • Spatial Resolution (IFOV): 8.89mrad
  • Thermal Sensitivity (NETD): < 0.05°C @ +30°C (+86°F) / 50 mK
  • Focus: Focus-free
  • Focal Length: 1.35mm
  • Detector Type/Operating Wavelength: Uncooled microbolometer / 7.5‒14 µm
  • LCD Display: 2.0 inch LCD, 240x320 pixels
  • Image Mode: Infrared light
  • Color Palettes: Iron red, rainbow, white hot, black hot, brown, blue red, hot cold, feather
  • Temperature Range 1: ‒20°C to +150°C (‒4°F to +302°F)
  • Temperature Range 2: 100°C to +550°C (+212°F to +1022°F)
  • Accuracy: ±2°C (±3.6°F) or ±2% of reading (ambient temperature 10°C-35°C, object temperature > 0°C)
  • Point Analysis: Center point
  • High and Low Temperature Detection: Automatic capture
  • Measurement Correction: Emissivity, reflected temperature, ambient temperature
  • Working Ambient Temperature: -15°C to +50°C (5°F to +122°F)
  • Storage Ambient Temperature: ‒40°C to +70°C (‒40°F to +158°F)
  • Ambient Humidity (working and storage): 10%~90% (non-condensing)
  • Drop Resistance: 2m
  • Impact Resistance: 25g (IEC60068-2-29)
  • Vibration Resistance: 2g (IEC60068-2-6)
  • Weight (including battery): <500g
  • Dimensions (L W H): 234.8*75.49*100.7mm

A-BF RX-350 Specifications:

  • Infrared Resolution: 160x120
  • Infrared Response Band: 8 to 14μm
  • Pixel Size: 12um
  • NETD: ≤50mK@25C.@F/1.1
  • Lens Focal Length: 3.2mm
  • IFOV: 3.75mrad
  • Field of View: 35°x27°
  • Focus Mode: Focus-free
  • Temperature Measurement Range: -20℃ to +550℃ (-4F to 1022F)
  • Temperature Measurement Accuracy: ±2℃ (35.6F) or ±2%
  • Temperature Measurement Resolution: 0.1℃
  • Temperature Measurement Mode: Center point/hot and cold spot tracking
  • Color Palette: Rainbow/iron red/cold color/white hot/black hot
  • Emissivity Setting: 0.01 to 1.00 adjustable
  • Thermal Imaging Frame Rate: <25Hz
  • Visible Light Resolution: 640x480
  • Display Screen Size: 2.8 inches (240x320)
  • Image Display Mode: Infrared/visible light/dual light fusion
  • Lighting System: LED fill light
  • Equipment Storage: Built-in 4G eMMC (user available storage space is about 3G)
  • Storage Image/Video Format: JPG/MP4
  • Image/Video Export Method: USB connection computer export
  • Image Analysis Function Support: PC offline analysis
  • Menu Language: Chinese, English, German, Italian
  • Battery Type: Removable rechargeable lithium battery (18650)
  • Battery Capacity: 2200mAh
  • Working Time: 2 to 3 hours
  • Power Interface: Micro USB
  • Power Configuration: 5 minutes/20 minutes/no automatic shutdown
  • Operating Temperature: -10℃ to +50℃
  • Storage Temperature: -20℃ to +60℃
  • Relative Humidity: 10% to 85%RH (non-condensing)
  • Product Weight: 389g
  • Product Size: 96mmX72mmX22ómm
Comparison table of A-BF thermal imager models
Figure 13: Comparison table of different A-BF thermal imager models (RX-300, RX-350, RX-500, RX-550, RX-600, RX-680) and their key specifications.

User Tips

  • For best accuracy, allow the imager to stabilize in the measurement environment for a few minutes before use.
  • Always adjust the emissivity setting to match the material you are inspecting. Common emissivity values can be found online or in specialized guides.
  • When inspecting electrical components, ensure the power is off or take extreme caution to avoid electrical hazards.
  • Utilize the PC software for detailed analysis and reporting, especially for professional applications.
  • Keep the lens clean to ensure clear and accurate thermal images.

Warranty and Support

Your A-BF Thermal Imager comes with a 1-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.

A-BF RX-300 highlighting 1-year warranty
Figure 14: A-BF RX-300 Thermal Imager indicating a 1-year warranty.

For technical support, warranty service, or any questions regarding your device, please contact your retailer or the manufacturer's customer service. Contact information can typically be found on the product packaging or the official A-BF website.

© 2023 A-BF. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.