1. Introduction
The JIKONG JK-B2A24S20PHCR is an advanced Active Battery Management System (BMS) designed for a wide range of battery configurations, specifically supporting 8S to 24S series LiFePO4, Li-ion, and LTO batteries. This BMS features an Inverter Protocol Version, enabling seamless communication with various inverter brands. It integrates essential functions such as active balancing, comprehensive protection mechanisms, and multiple communication interfaces including CAN and RS485, alongside Bluetooth connectivity for mobile app monitoring. Its robust design, featuring a fully enclosed aluminum alloy shell, ensures high efficiency, durability, and superior heat dissipation.
2. Package Contents
Please verify that all items listed below are included in your package:
- 1 x JIKONG JK-B2A24S20PHCR BMS Unit
- 1 x Communication Board
- 1 x Switch Key
- 1 x Sampling Cable (long 70cm)
- 1 x NTC (Negative Temperature Coefficient) Sensor (long 40cm)
3. Specifications
The JIKONG JK-B2A24S20PHCR BMS offers the following technical specifications:
| Feature | Specification |
|---|---|
| Model | JK-B2A24S20PHCR |
| Number of Battery Strings | 8S-24S (Li-ion, LiFePO4, LTO) |
| Continuous Discharge Current | 200A |
| Continuous Charge Current | 200A |
| Maximum Discharge Current (MAX 2min) | 350A |
| Over Charge Protection Current (J) | 10-200A |
| Over Discharge Protection Current (ADJ) | 10-200A |
| Balance Current | 2A (Active Balance) |
| Communication Interfaces | RS485, CANBUS, Bluetooth |
| Other Interfaces | HEAT, GPS, Display/Switch |
| Overcharge Protection | Yes |
| Over Discharge Protection | Yes |
| Overcurrent Protection | Yes |
| Short Circuit Protection | Yes |
| Temperature Detection | 3 NTC sensors |
| Dimensions (L x W x H) | 162mm x 102mm x 16.6mm (approx.) |
| Certifications | CE, FCC, RoHS |
4. Setup & Installation
Proper installation and wiring are crucial for the safe and efficient operation of your BMS. Please follow these steps carefully:
- Connect all cables: Ensure all necessary cables, including sampling lines, NTC sensors, and communication cables, are prepared.
- Insert the cable into the BMS: Carefully connect the sampling cables to the designated ports on the BMS.
- Connect the B-line and P-line to the battery: Connect the main negative (B-) and positive (P-) lines from the BMS to your battery pack.
4.1. BMS Interface Overview
The BMS unit features various interfaces for comprehensive battery management and communication:
- CAN/RS485: For inverter communication and external devices.
- NTC: Temperature sensor input.
- GPS: Optional GPS module connection.
- Display/Switch: For external display or soft switch.
- Hot: Heating function output.
- Sampling Port A/B: For connecting cell voltage sampling lines.
4.2. Wiring Diagrams
Refer to the following diagrams for correct wiring of your battery cells to the BMS:
Important: Always ensure correct polarity and sequence when connecting balance wires and main power cables to avoid damage to the BMS or battery pack. Consult a qualified professional if you are unsure about any wiring steps.
5. Operating Instructions
The JIKONG BMS can be monitored and configured via a mobile application or PC software.
5.1. Mobile App Connectivity
The BMS supports iOS, Android, and HarmonyOS systems. Download the "JIKONG SMART BMS" app from your device's app store. Once installed, connect to the BMS via Bluetooth to monitor real-time data and adjust settings.
The app provides a clear overview of:
- Voltage (Total and individual cell voltages)
- Current (Charge/Discharge)
- Temperature (NTC sensor readings)
- State of Charge (SOC)
- Alarms and Protection Status
- Cycle Count
You can freely adjust multiple protection values such as overcharge, overdischarge, overcurrent, temperature, and balance settings through the app. Always read the internal parameters of the protection board before making changes.
5.2. PC Software and Inverter Protocol
The BMS also supports PC software for detailed monitoring and configuration, including setting up inverter communication protocols.
The inverter communication protocol can be set via the host computer. The BMS is compatible with mainstream inverter communication protocols in the market.
| Brand | Protocol Name |
|---|---|
| JIKONG | NIU, China tower |
| Growatt | Voltronic, WOW |
| Other | Pylon, Deye, Victron Energy, Sofar, Invt, SMA, SRNE (check app for specific protocol versions) |
6. Maintenance
The JIKONG JK-B2A24S20PHCR BMS is designed for durability and high performance with minimal maintenance. Its fully enclosed aluminum alloy shell provides excellent dustproof, waterproof, anti-voltage, and anti-vibration properties, reducing the risk of damage to internal electronic components.
- Cleaning: Keep the exterior of the BMS clean and free from dust and debris. Use a dry, soft cloth for cleaning. Avoid using liquids or abrasive cleaners.
- Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to poor performance or damage.
- Environment: While the BMS is robust, avoid exposing it to extreme temperatures, direct sunlight for prolonged periods, or highly corrosive environments.
- Firmware Updates: Check the official JIKONG website or app for any available firmware updates to ensure optimal performance and access to new features.
7. Troubleshooting
If you encounter issues with your JIKONG BMS, consider the following common troubleshooting steps:
- No Power/No Display:
- Check all main power connections (B- and P+) to ensure they are correctly and securely attached.
- Verify the battery pack voltage is within the operational range of the BMS.
- Ensure the switch key is in the 'ON' position if an external switch is used.
- App Connection Issues:
- Ensure Bluetooth is enabled on your mobile device.
- Make sure the BMS is powered on and within Bluetooth range.
- Restart the mobile app and try reconnecting.
- Check if the app is updated to the latest version.
- Inaccurate Readings (Voltage/Current):
- Verify that all cell voltage sampling lines are correctly connected and in the right sequence.
- Ensure the NTC temperature sensors are properly installed and making good contact with the battery cells.
- BMS Entering Protection Mode:
- Check the app or PC software for specific fault codes or protection triggers (e.g., overcharge, overdischarge, overcurrent, high/low temperature).
- Address the underlying cause (e.g., reduce load, adjust charging parameters, ensure proper ventilation).
If the problem persists after attempting these steps, please contact JIKONG customer support for further assistance.
8. User Tips
- Initial Setup: Double-check all wiring, especially the balance leads, before applying power to prevent damage. Incorrect wiring is a common cause of initial setup issues.
- App Monitoring: Regularly use the mobile app to monitor your battery's health, cell voltages, and temperature. This helps in early detection of potential issues.
- Parameter Adjustment: When adjusting protection parameters via the app or PC software, make small, incremental changes and observe the system's behavior. Always understand the implications of each setting.
- Inverter Compatibility: Ensure your inverter's communication protocol is supported by the BMS. Refer to the supported protocols list in the operating instructions and the app's settings.
9. Warranty & Support
For any technical support, warranty claims, or inquiries regarding your JIKONG JK-B2A24S20PHCR BMS, please contact the JIKONG Official Store or your authorized dealer. Provide your product model and a detailed description of the issue to facilitate efficient support.