OLEY AC-118

Contents

OLEY AC-118 Digital Temperature Controller Thermostat

Model: AC-118

Introduction

The OLEY AC-118 Digital Temperature Controller is designed to precisely regulate temperature in various environments, such as aquariums, terrariums, and reptile enclosures. Featuring a bright LED display and intuitive controls, it offers both heating and cooling functions to maintain optimal conditions for your pets or plants. This manual provides essential information for safe and effective use of your device.

Video: Overview of the OLEY AC-118 Digital Temperature Controller's features and operation.

Safety Information

  • Ensure the device is connected to a power source that matches its voltage requirements (220V for EU Plug).
  • Do not immerse the main unit in water. Only the NTC sensor is waterproof.
  • Keep the device away from direct sunlight, high temperatures, and corrosive environments.
  • Do not attempt to disassemble or repair the device yourself. Contact qualified personnel for service.
  • Unplug the device from the power outlet before cleaning or performing any maintenance.

Product Overview

The OLEY AC-118 features a compact design with an integrated EU plug socket for connecting your heating or cooling appliance. The front panel includes a clear LED display and control buttons. A waterproof NTC sensor with a 1.05m cable is included for accurate temperature measurement.

Front view of OLEY AC-118 Digital Temperature Controller showing the display and control buttons.

Image: Front view of the OLEY AC-118 Digital Temperature Controller with its LED display and control buttons.

Close-up of the control buttons: H/C, SET, Up arrow, Down arrow.

Image: Close-up of the control buttons (H/C, SET, Up, Down arrows).

Top-down view of the thermostat with the NTC sensor and power cable.

Image: Top-down view showing the thermostat, NTC sensor, and power cable.

Setup

  1. Mounting the Controller

    The controller can be placed on a flat surface or mounted on a wall using the integrated mounting holes on the back of the unit.

    Bottom view of the thermostat showing mounting holes.

    Image: Bottom view of the thermostat, indicating mounting holes.

  2. Sensor Placement

    Place the waterproof NTC sensor in the environment where temperature needs to be controlled (e.g., inside an aquarium or terrarium). Use the provided suction cup to secure the sensor in place. Ensure the sensor is fully submerged if used in water, or positioned to accurately reflect ambient air temperature if used in air.

    Close-up of the NTC sensor with its suction cup.

    Image: NTC sensor with suction cup for easy placement.

  3. Connecting the Appliance

    Plug your heating or cooling device (e.g., aquarium heater, reptile heat lamp, cooling fan) into the EU socket on the side of the temperature controller.

    Close-up of the EU plug and the thermostat's socket.

    Image: Close-up of the EU plug and the thermostat's integrated socket.

  4. Powering On

    Plug the temperature controller's power cord into a suitable 220V EU wall outlet. The LED display will light up, showing the current measured temperature.

Operating Instructions

Button Functions:

  • H/C Button: Toggles between Heating (HEAT) and Cooling (COOL) modes.
  • SET Button: Enters temperature setting mode.
  • Up Arrow (∧) Button: Increases values in setting mode.
  • Down Arrow (∨) Button: Decreases values in setting mode.

Setting Desired Temperature:

  1. Press the SET button once. The display will flash, showing the current set temperature.
  2. Use the Up (∧) or Down (∨) arrows to adjust the desired temperature.
  3. Press SET again or wait a few seconds for the setting to be saved automatically.

Setting Temperature Difference (Hysteresis):

This setting determines the temperature range around your set point before the heating or cooling device activates. For example, if set to 1°C and target is 25°C in heating mode, heating will turn on at 24°C and off at 25°C.

  1. Press and hold the SET button for 3 seconds to enter advanced settings.
  2. Use the Up (∧) or Down (∨) arrows to navigate through settings until you find the temperature difference parameter (often indicated by 'd' or 'H').
  3. Press SET to view the current value, then use Up (∧) or Down (∨) to adjust.
  4. Press SET again to confirm, then hold SET for 3 seconds or wait to exit.

Setting Output Delay (Compressor Protection):

This function adds a delay before the heating/cooling device turns on again, protecting compressors from rapid cycling. This is particularly useful for cooling devices.

  1. Press and hold the SET button for 3 seconds to enter advanced settings.
  2. Use the Up (∧) or Down (∨) arrows to navigate through settings until you find the output delay parameter (often indicated by 'P' or 'Cd').
  3. Press SET to view the current value, then use Up (∧) or Down (∨) to adjust the delay time in minutes.
  4. Press SET again to confirm, then hold SET for 3 seconds or wait to exit.

Display Icons:

  • HEAT: Indicates the heating function is active.
  • COOL: Indicates the cooling function is active.
  • SNOWflake: Typically indicates cooling mode is selected.
  • SUN: Typically indicates heating mode is selected.
Close-up of the display showing temperature and 'HEAT' indicator.

Image: Close-up of the LED display showing current temperature and the 'HEAT' indicator.

Maintenance

  • Cleaning the Unit: Wipe the main unit with a soft, damp cloth. Do not use abrasive cleaners or immerse the unit in water.
  • Sensor Care: Regularly check the NTC sensor for any buildup or damage. Clean it gently with water if necessary. Ensure the sensor cable is not kinked or damaged.
  • Power Cord: Inspect the power cord periodically for any signs of wear or damage.

Troubleshooting

Common Issues and Solutions:

  • Display is blank or not working:
    • Check if the power cord is securely plugged into a working outlet.
    • Ensure there is power to the outlet.
  • Temperature reading seems inaccurate:
    • Verify the NTC sensor is correctly placed and clean.
    • Ensure the sensor cable is not damaged.
    • Allow some time for the sensor to stabilize in the environment.
  • Connected appliance is not heating/cooling:
    • Check if the appliance itself is functional by plugging it directly into a wall outlet.
    • Ensure the desired temperature is set correctly and the controller is in the appropriate mode (HEAT/COOL).
    • Verify the temperature difference (hysteresis) and output delay settings are not preventing activation.
    • Confirm the appliance is securely plugged into the controller's socket.

Specifications

Feature Specification
Model Number AC-118
Plug Type EU Plug
Voltage 220V
Power (W) 3W (Controller Consumption)
Temperature Measuring Range -40 to 110 °C
Temperature Control Range 16 to 40 °C
Resolution 0.1 °C
Accuracy +/- 1 °C
Sensor Type Water-proof NTC Sensor
Sensor Cable Length 1.05m
Ambient Temperature Requirements -10 to 60 °C
Ambient Humidity Requirements 20% to 85%
Item Size (Main Body) 13.6 x 5.6 x 4cm / 5.32 x 2.17 x 1.57in

User Tips

  • The functions are generally easy to set, making initial setup straightforward.
  • Before fully relying on the thermostat for critical temperature control, it is recommended to test its functionality with your specific heating/cooling device to ensure it operates as expected.
  • Regularly monitor the actual temperature with a separate thermometer to cross-reference readings and ensure accuracy.

Warranty and Support

For warranty information or technical support, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.