1. Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your RONIX RC-0200 Air Compressor. Please read this manual thoroughly before operating the unit and keep it for future reference.

Figure 1: RONIX RC-0200 Air Compressor
2. Safety Information
Always follow basic safety precautions to reduce the risk of fire, electric shock, and personal injury when using this product.
- Ensure the compressor is placed on a stable, level surface.
- Do not operate the compressor in wet or damp conditions.
- Always wear appropriate personal protective equipment (PPE), such as eye protection.
- Before performing any maintenance, ensure the compressor is unplugged and the tank is fully depressurized.
- Do not modify the pressure settings beyond the recommended limits.
- Keep children and unauthorized personnel away from the operating compressor.
3. Product Features
The RONIX RC-0200 Air Compressor is designed for continuous application with a focus on quiet operation and efficiency.
- Hyper Silent Motor: Engineered for reduced noise during operation.
- Induction Motor: Provides reliable performance for continuous use.
- High Capacity Tank: 200L tank for extended operation.
- Dual Cylinders: Efficient air compression.
- Portable Design: Equipped with 6-inch casters for easy movement.

Figure 2: Key features of the RC-0200 Air Compressor
4. Setup and Assembly
The RC-0200 Air Compressor requires minimal assembly, primarily for attaching the wheels.
- Unpacking: Carefully remove the compressor from its wooden box packaging. Inspect for any shipping damage.
- Wheel Assembly:
- Attach the 4 pieces of 6-inch 20-hole black casters to the designated mounting points on the compressor base.
- Secure each caster using the provided 4MM split pins and 21mm flat pads. Ensure all fasteners are tightened securely.
- Placement: Position the compressor on a firm, level surface in a well-ventilated area. Ensure there is adequate space around the unit for air circulation and maintenance access.
- Electrical Connection: Connect the compressor to a grounded 220-240V, 50Hz power outlet. Ensure the power supply matches the compressor's requirements.
- Initial Check: Before first use, ensure all connections are secure and there are no visible leaks or damage.
5. Operating Instructions
Familiarize yourself with the controls and indicators before operating the compressor.

Figure 3: Detail of controls (pressure gauge, quick connect, pressure switch)
- Power On: Plug the compressor into a suitable electrical outlet. The pressure switch (often a red button or lever) will typically have ON/OFF markings. Pull the red button up to turn ON the compressor.
- Pressure Adjustment: The compressor is equipped with a pressure gauge and a regulator.
- The maximum operating pressure is 0.8MPa (8 bar).
- The safety valve opens at 0.9MPa to prevent over-pressurization.
- The compressor will restart automatically when the pressure drops to 0.6MPa.
- Adjust the output pressure using the regulator knob to suit your pneumatic tool's requirements within the 0.1-0.8MPa use pressure range.
- Connecting Tools: Attach your pneumatic tool to the quick-connect coupler. Ensure a secure connection.
- Operation: Once the desired pressure is reached and the tool is connected, you can begin using your pneumatic tools. The compressor will cycle on and off automatically to maintain tank pressure.
- Power Off: Push the red button down to turn OFF the compressor.
- Depressurizing: After use, always depressurize the air tank by opening the drain valve or using an air tool until the pressure gauge reads zero.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your air compressor.
- Daily:
- Drain condensation from the air tank. This prevents rust and extends tank life.
- Check for any unusual noises or vibrations.
- Weekly/Monthly:
- Inspect air filter for cleanliness. Clean or replace if necessary.
- Check all fittings and hoses for leaks. Tighten as needed.
- Verify the safety valve operates correctly by briefly pulling its ring.
- Annually:
- Inspect the power cord for damage.
- Have a qualified technician inspect the compressor for wear and tear.
Warning: Always unplug the compressor and depressurize the tank before performing any maintenance.
7. Troubleshooting
This section covers common issues you might encounter with your air compressor.
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor does not start | No power; ON/OFF switch in OFF position; Thermal overload activated. | Check power connection; Ensure switch is ON; Allow motor to cool and reset thermal overload. |
| Compressor runs continuously or frequently | Air leak in tank or connections; Excessive air consumption; Pressure switch malfunction. | Check for leaks using soapy water; Reduce air tool usage; Consult service technician. |
| Low air pressure output | Air leaks; Clogged air filter; Regulator set too low. | Check for leaks; Clean/replace air filter; Adjust regulator to desired pressure. |
| Excessive noise or vibration | Loose components; Worn motor bearings; Unstable surface. | Tighten all fasteners; Consult service technician; Place on a stable, level surface. |
8. Specifications
| Feature | Specification |
|---|---|
| Model | RC-0200 |
| Voltage | 220-240V |
| Power | 2200W |
| Tank Capacity | 200L |
| Frequency | 50Hz |
| Speed | 1000 RPM |
| Air Delivery | 370 L/min |
| Max Pressure | 0.8 MPa (8 bar) |
| Safety Valve Opening | 0.9 MPa |
| Restart Pressure | 0.6 MPa |
| Use Pressure Range | 0.1-0.8 MPa |
| Weight (G.W) | 120 kg |
| Dimension (L*W*H) | 140*50*98 cm |
| Configuration | Stationary |
| Power Source | Air |
| Mute | Yes |
| Core Components | Engine |
| Supplied In | Wooden box |
| Includes | 6 inch 20 hole black casters 4pcs, 4MM split pin 4pcs, 21mm flat pad 4pcs |
9. Warranty and Support
The RONIX RC-0200 Air Compressor comes with a 1-year warranty for core components. For any issues or support, please contact your seller or an authorized service center.
The manufacturer is responsible for the supplied product within its usage life.
10. User Tips
- Always ensure the air hose and connections are free from kinks or damage to maintain optimal airflow and prevent leaks.
- For best performance and to prolong the life of your pneumatic tools, use an inline air filter/regulator/lubricator (FRL unit) if your tools require lubrication.
- Regularly check the pressure gauge for accurate readings.
- Store the compressor in a dry, clean environment when not in use.
11. Frequently Asked Questions (FAQ)

Figure 4: Common questions and answers
- Q: What about the after-sales service?
- A: Our company is responsible for the supplied product within its usage life.
- Q: Can you help me design or modify the products as we request?
- A: We develop new products with your requested quality through our R&D department. Our professional design team can assist if the Minimum Order Quantity (MOQ) is met.
- Q: What about the samples?
- A: We can supply samples. A sample fee will be charged and returned after the order is confirmed. The customer is responsible for the shipping fee when a specific delivery method is required.