1. Introduction
The TTNergy SM-H Series Hybrid Solar Inverter is a versatile power solution designed for both on-grid and off-grid solar power systems. It integrates a solar charge controller, inverter, and battery charger into one unit to offer uninterruptible power support. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SM-H series inverter.
2. Safety Information
Please read and understand all instructions and warnings in this manual before installing, operating, or servicing this inverter. Failure to follow these instructions may result in electric shock, fire, severe injury, or death.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly polarized and securely connected.
- Do not attempt to disassemble or repair the inverter yourself. Contact qualified service personnel.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (solar, utility, battery) before performing any maintenance or wiring.
- Wear appropriate personal protective equipment (PPE) during installation and maintenance.
3. Product Overview
3.1. Components
The SM-H series inverter features a user-friendly interface and robust connection points.

Figure 1: Front View of the SM-H Inverter showing LCD display and control buttons.

Figure 2: Rear View of the SM-H Inverter showing connection terminals.
Front Panel:
- LCD Display: Shows system status, operating parameters, and error messages.
- Control Buttons: For navigation and setting configuration (Power, Up, Down, Enter).
- LED Indicators: Provide quick visual status (e.g., Inverting, Charging, Fault).
Rear Panel:
- AC IN: Terminal for connecting to the utility grid or generator.
- AC OUT: Terminal for connecting to household loads.
- Input Breaker: Overcurrent protection for the AC input.
- BATTERY (+/-): Terminals for connecting to the battery bank.
- PV IN (+/-): Terminals for connecting to solar PV array.
- Communication Interface: RS232 (Standard), GPRS/WIFI (Optional) for monitoring.
3.2. Key Features
- Pure sine wave output for sensitive electronics.
- Configurable AC/Solar input priority via LCD setting.
- Smart battery charging design for optimized battery performance.
- Overload, high temperature, and inverter output short circuit protection.
- Cold start function for system startup without AC input.
- External battery compatibility.
- Optional WiFi monitoring and setting capabilities.
- Optional dust filter for enhanced durability.
4. Setup
4.1. Installation Location
- Mount the inverter vertically on a wall in a well-ventilated area.
- Ensure the ambient temperature is within the operating range (-10°C to 55°C).
- Avoid direct sunlight, moisture, and dust.
- Maintain sufficient clearance around the inverter for proper airflow.
4.2. Wiring Connections
All wiring should be performed by a qualified electrician. Ensure all power sources are disconnected before making any connections.

Figure 3: Solar System Connection Diagram
- PV Array Connection: Connect the positive and negative terminals of your solar panels to the 'PV IN +' and 'PV IN -' terminals on the inverter. Ensure the PV array voltage is within the specified MPPT range and does not exceed the maximum open circuit voltage.
- Battery Connection: Connect the positive and negative terminals of your battery bank to the 'BATTERY +' and 'BATTERY -' terminals. Ensure correct polarity. The inverter supports 12VDC (SM-2200H) or 24VDC (SM-3200H) battery systems.
- AC Input Connection: Connect the utility grid or a generator to the 'AC IN' terminals. Ensure the input voltage is within the selectable range (170-280VAC for PC, 90-280VAC for home appliances).
- AC Output Connection: Connect your household loads to the 'AC OUT' terminals.
- Grounding: Ensure the inverter is properly grounded according to local electrical codes.
5. Operating Instructions
5.1. Initial Startup
- After all connections are secure, switch on the battery breaker (if applicable).
- Switch on the AC input breaker (if connected to utility/generator).
- Press and hold the Power button on the inverter's front panel for a few seconds until the LCD display illuminates.
- The inverter will perform a self-test and then display the current operating status.
5.2. LCD Display and Settings
The LCD display provides real-time information about the system. Use the Up, Down, and Enter buttons to navigate through menus and adjust settings such as:
- Output Source Priority: Configure whether the inverter prioritizes solar, utility, or battery power for loads.
- Charging Source Priority: Set the preferred charging source for the battery (solar, utility, or both).
- Battery Type: Select the type of battery connected (e.g., AGM, Flooded, Lithium).
- Charging Current: Adjust the maximum battery charging current.

Figure 4: LCD Display and LED Indicators
5.3. Shutdown Procedure
- Disconnect all AC loads from the inverter.
- Press and hold the Power button until the inverter shuts down.
- Switch off the AC input breaker.
- Switch off the battery breaker.
- Disconnect the PV array.
6. Maintenance
- Regular Cleaning: Keep the inverter's exterior clean and free of dust. If equipped with an optional dust filter, clean or replace it periodically to ensure proper airflow.
- Ventilation Check: Ensure that the ventilation openings are not blocked and that there is sufficient space around the inverter for heat dissipation.
- Connection Inspection: Periodically check all wiring connections (PV, battery, AC input/output) for tightness and signs of corrosion or damage.
- Battery Health: Monitor battery voltage and health as recommended by the battery manufacturer.
- Environmental Conditions: Ensure the operating environment remains within specified temperature and humidity ranges.
7. Troubleshooting
This section provides solutions to common issues. For problems not listed here, please contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not turn on | No battery connection or low battery voltage | Check battery connections and ensure battery voltage is above minimum operating level. |
| No AC output | Overload, short circuit, or inverter fault | Reduce load, check for short circuits, or check LCD for fault codes. Restart inverter. |
| Battery not charging | PV array disconnected, low PV voltage, or AC input not present | Check PV connections, ensure sufficient sunlight, or verify AC input is active. Check charging settings. |
| Overload warning/shutdown | Connected loads exceed inverter capacity | Reduce the total load connected to the inverter. |
8. Specifications
| Specification | SM-2200H | SM-3200H |
|---|---|---|
| Rated Power | 2200VA/1800W | 3200VA/3000W |
| Input Voltage | 230VAC | |
| Selectable Voltage Range | 170-280VAC (for personal computers), 90-280VAC (for home appliances) | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| AC Voltage Regulation (Batt.Mode) | 230VAC±5% | |
| Surge Power | 4400VA | 6400VA |
| Transfer Time | 10ms (for personal computers), 20ms (for home appliances) | |
| Wave form | Pure Sine Wave | |
| Battery Voltage | 12VDC | 24VDC |
| Floating Charge Voltage | 13.5VDC | 27VDC |
| Overcharge Protection | 16VDC | 33VDC |
| Maximum Charge Current | 60A | |
| MAX. PV Array Power | 2000W | 3000W |
| MPPT Range @ Operating Voltage | 90-450VDC | |
| Maximum PV Array Open Circuit Voltage | 450VDC | |
| Maximum Charging Current (Solar) | 80A | |
| Maximum Efficiency | 98% | |
| Dimension (D*W*H) | 348*259*105mm | |
| Net Weight | 5KG | 5.5KG |
| Communication Interface | RS232 (Standard), GPRS/WIFI (Optional) | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Operating Temperature | -10°C to 55°C | |
| Storage Temperature | -15°C to 60°C | |
9. User Tips
- Monitor Regularly: Periodically check the LCD display for system status and any alerts to ensure optimal performance.
- Optimize Settings: Experiment with the output and charging source priorities to best suit your energy consumption patterns and solar availability.
- Battery Compatibility: Always ensure your battery bank's voltage and capacity are compatible with your specific inverter model (12VDC for SM-2200H, 24VDC for SM-3200H).
- Ventilation is Key: Good airflow prevents overheating and extends the life of your inverter. Never block the vents.
10. Warranty and Support
The TTNergy SM-H Series Hybrid Solar Inverter comes with a 12-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For technical support, troubleshooting assistance, or warranty claims, please contact your seller or authorized service center. Provide your product model number and a detailed description of the issue when seeking support.