AUTOOL LM130

AUTOOL LM130 Smart Digital Manifold Kit User Manual

Model: LM130

1. Introduction

The AUTOOL LM130 is a digital intelligent refrigerant meter designed for use in automotive air conditioning maintenance. This device accurately measures pressure values of refrigerants at various stages within the system, providing essential data for equipment operation and maintenance personnel. It ensures a clear understanding of the air conditioning system's operational status, contributing to its proper functioning.

Key features include a high-precision sensor, multiple operating modes (refrigeration, evacuation, pressure leak test), and a clear LCD HD display for easy readability in various lighting conditions.

2. Safety Information

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with refrigerants.
  • Ensure proper ventilation in the work area to prevent the accumulation of refrigerant vapors.
  • Do not expose the device to extreme temperatures, direct sunlight, or corrosive environments.
  • Handle refrigerant cylinders with care and follow all manufacturer guidelines for their use and storage.
  • Disconnect the device from the system before performing any maintenance or cleaning.
  • Keep the device away from children and unauthorized personnel.

3. Package Contents

Verify that all items are present in the package:

  • AUTOOL LM130 Smart Digital Manifold Kit Unit
  • Temperature Probe (Clamp Type)
  • User Manual
  • Storage Box
Image showing the AUTOOL LM130 unit, its packaging box, a clamp temperature probe, and the user manual.

Figure 1: Package Contents of the AUTOOL LM130

4. Device Overview

The AUTOOL LM130 features a robust design with intuitive controls and a clear display. Familiarize yourself with the components and their functions:

Diagram of the AUTOOL LM130 showing its dimensions and labeled components: Multi-Function interface, Display Screen, buttons for start/pause, sound on/off, settings, measurement mode, power, Refilling hose brass connector, Observation sight window, Refilling hose joint evacuation port, Rotary knob, and Foldable Hook.

Figure 2: AUTOOL LM130 Components and Controls

LabelComponentFunction
AMulti-Function interfaceMain display area for readings and settings.
BDisplay ScreenHigh-definition LCD for clear data presentation.
CPlay/Pause ButtonPress to start/pause measurement / restart measurement; In setting mode, press to scroll upward.
DSound/Scroll Down ButtonPress to control the sound on/off; In setting mode, press to scroll downward.
ESettings ButtonPress to open the settings menu (refrigerant selection, temperature unit selection, pressure unit selection, vacuum unit selection, auto power off selection).
FMeasurement Mode ButtonPress to select the measurement mode; long press to zero the pressure.
GPower/Backlight ButtonPress to power on the unit; long press for 2s to power off; press to control backlight.
HRefilling hose brass connectorConnection point for refrigerant hoses.
IObservation sight windowAllows visual inspection of refrigerant flow.
JRefilling hose joint evacuation portPort for evacuation hose connection.
KRotary knobUsed for controlling valves or settings.
MFoldable HookFor hanging the unit during use.
Close-up images of the AUTOOL LM130 showing its foldable hook, multi-button layout, observation sight window, and silicone sides.

Figure 3: Unique Design Details of the AUTOOL LM130

5. Specifications

The AUTOOL LM130 is engineered with the following technical specifications:

Table of product specifications for the AUTOOL LM130, including Pressure Unit, Temperature Unit, Vacuum Unit, Pressure Range, Temperature Range, Vacuum Range (Rel), Pressure Resolution, Temperature Resolution, Pressure Accuracy, Temperature Accuracy, Vacuum Accuracy, Overload, Refrigerants Available, and Operating Voltage.

Figure 4: AUTOOL LM130 Technical Specifications

ParameterValue
Pressure Unitpsi, Bar, Mpa
Temperature Unit°C, °F
Vacuum UnitTorr, mbar
Pressure Range0~870psi, 0~60bar(rel), 0~6Mpa
Temperature Range-55~125°C, -67~257°F
Vacuum Range (Rel)-14.7-0psi, -1~0bar
Pressure Resolution0.1psi, 0.01bar, 0.005MPa
Temperature Resolution0.1°C, 0.1°F
Pressure AccuracyWithin ±0.5% of the full range
Temperature Accuracy±0.5°C (±1 digit), ±0.9°F (±1 digit)
Vacuum AccuracyWithin ±0.5% of the full range
Overload942.5psi, 65bar, 6.5Mpa
Refrigerants AvailableR12, R410A, R407C, R404A, R22, R134A, R502
Operating Voltage6V (4 x 1.5V batteries)

6. Setup and Initial Use

Before operating the AUTOOL LM130, ensure it is properly set up:

  1. Battery Installation: Open the battery compartment and insert four 1.5V batteries, ensuring correct polarity.
  2. Power On: Press the power button (G) to turn on the unit. The LCD HD display (B) will illuminate.
  3. Unit Selection: Press the settings button (E) to enter the settings menu. Use the scroll buttons (C, D) to navigate and select your preferred pressure, temperature, and vacuum units.
  4. Refrigerant Type Selection: In the settings menu, select the appropriate refrigerant type (e.g., R134A, R22) for your application using the rotary knob (K) or scroll buttons.
  5. Connect Hoses: Connect the appropriate refrigerant hoses to the refilling hose brass connectors (H) and the refilling hose joint evacuation port (J) as required for your specific task.
  6. Attach Temperature Probe: If temperature measurement is needed, attach the clamp temperature probe to the pipe.

Watch this video for a quick overview of the device in action:

Video 1: AUTOOL LM130 Smart Digital Manifold Kit Demonstration

7. Operating Modes

The AUTOOL LM130 offers several operating modes for comprehensive system analysis:

7.1 Refrigeration Mode

This mode provides real-time measurement of pressure and temperature data within refrigeration systems. It displays key parameters to help assess system performance.

Display of the AUTOOL LM130 in Refrigeration Mode, showing Refrigerant Type (R134A), Refrigerant Evaporation Pressure Temperature (EV), Refrigerant Condensation Pressure Temperature (CO), Measured Pipe Temperature (T), and Real-time Pressure (Current P).

Figure 5: Refrigeration Mode Display

Display AbbreviationDescription
EVEvaporation Temperature
COCondensation Temperature
TActual Pipe Temperature
Current PCurrent Pressure

7.2 Evacuation Mode

This mode is used to measure pressure during the evacuation process of a refrigeration system and assess the current vacuum state. It helps ensure proper removal of non-condensable gases and moisture.

Display of the AUTOOL LM130 in Evacuation Mode, showing Evacuation Mode, H2O Evaporation Temp (Ev), Ambient Temp (Tamb), Current Pressure (Current P), Delta T (ΔT), Measurement Duration (TIME), and an indicator for Vacuum Not Achieved Within Range (000000) or Activate External Vacuum Probe (RUAT).

Figure 6: Evacuation Mode Display

Display AbbreviationDescription
EvacuationEvacuation Mode
EvH2O Evaporation Temp.
TambAmbient Temp.
Current PCurrent Pressure
ΔTDelta T
TIMEMeasurement Duration
000000Vacuum Not Achieved Within Range
RUATActivate External Vacuum Probe

7.3 Pressure Leak Test

This mode is used to test the leak tightness and sealing integrity of the refrigeration system. It monitors pressure changes over time to detect potential leaks.

Display of the AUTOOL LM130 in Pressure Leak Test mode, showing Starting Pressure (StartP), Real-time Pressure (Current P), Pressure Difference (ΔP), and Measurement Time (TIME).

Figure 7: Pressure Leak Test Display

Display AbbreviationDescription
Pressure Leak TestPressure Leak Test Mode
StartPStart Pressure
Current PCurrent Pressure
ΔPDelta Pressure
TIMEMeasurement Duration

8. User Tips

  • Always ensure the correct refrigerant type is selected in the settings before taking measurements to avoid inaccurate readings.
  • For precise temperature readings, ensure the clamp temperature probe is securely attached to the pipe and has good contact.
  • Regularly check battery levels, especially before critical measurements, to prevent unexpected power loss.
  • Utilize the foldable hook to hang the unit securely, keeping it stable and visible during operation.
  • When performing a pressure leak test, allow sufficient time for the system to stabilize before starting the measurement for reliable results.

9. Maintenance

  • Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the unit in its original packaging or a protective case in a dry, cool place when not in use.
  • Battery Replacement: Replace batteries when the low battery indicator appears on the display. Remove batteries if the device will not be used for an extended period.
  • Sensor Care: Keep the pressure sensor ports clean and free from debris.

10. Troubleshooting

  • No Display/Unit Not Powering On: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • Inaccurate Readings: Verify that the correct refrigerant type and units are selected in the settings. Ensure proper connection of hoses and temperature probe. Calibrate the unit if necessary (refer to the long press function of the measurement mode button to zero pressure).
  • Buttons Unresponsive: Ensure the unit is not in a locked mode. Try powering off and on again.
  • Leak Test Fails: Recheck all connections for tightness. Ensure the system is properly sealed before initiating the test.

11. Warranty and Support

The AUTOOL LM130 Smart Digital Manifold Kit comes with a 3-year warranty from AUTOOL authorized stores. This warranty covers manufacturing defects and ensures product quality. For any technical assistance, troubleshooting, or warranty claims, please contact AUTOOL customer support through their official channels.

Image displaying a 3-year warranty badge for AUTOOL products.

Figure 8: AUTOOL 3-Year Warranty

Related Documents - LM130

Preview AUTOOL LM130 Smart Digital Manifold Kit User Manual
User manual for the AUTOOL LM130 Smart Digital Manifold Kit, detailing its features, operation, safety guidelines, maintenance, and specifications for automotive air conditioning system diagnostics and refrigerant measurement.
Preview AUTOOL LM150 Digital Manifold Pressure Tester User Manual - HVAC Refrigerant Tool
Comprehensive user manual for the AUTOOL LM150 Digital Manifold Pressure Tester. Covers product specifications, operating instructions for refrigerant filling, vacuum, and leak testing, common problems, glossary of terms, maintenance, warranty, and return policy for HVAC and refrigeration professionals.
Preview AUTOOL LM70 Smart Digital Manifold Kit User Manual
User manual for the AUTOOL LM70 Smart Digital Manifold Kit, providing detailed instructions on operation, safety, maintenance, and technical specifications for automotive air conditioning system diagnostics.
Preview AUTOOL LM160 Smart Digital Manifold Kit User Manual
Comprehensive user manual for the AUTOOL LM160 Smart Digital Manifold Kit, covering operation, technical specifications, maintenance, and safety for HVAC applications.
Preview AUTOOL LM110 Digital Manifold Gauge User Manual
User manual for the AUTOOL LM110 Digital Manifold Gauge, providing detailed instructions on its features, operation, specifications, and troubleshooting for refrigeration system maintenance.
Preview AUTOOL LM120/LM120+ Digital Manifold Gauge User Manual
This user manual provides comprehensive guidance for the AUTOOL LM120/LM120+ Digital Manifold Gauge. It details product specifications, structure, function instructions for refrigerant filling, vacuum operation, and pressure leak testing. The manual also includes common problems, a glossary of terms, maintenance advice, warranty information, and return/exchange procedures. Essential for HVAC technicians and refrigeration professionals.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.