INVT Goodrive20

Contents

INVT Goodrive20 Series Vector Inverter User Manual

Models: GD20-0R7G-4, GD20-1R5G-4, GD20-2R2G-4, GD20-004G-4, GD20-5R5G-4, GD20-7R5G-4

1. Introduction

The INVT Goodrive20 series inverter utilizes advanced speed sensorless vector control technology, offering exceptional driving performance and comprehensive control functions. Designed with a rich hardware configuration and powerful software, this series significantly enhances ease of use and reliability, catering to diverse industrial control applications.

Key features include a compact design for space-saving installation, and for models ranging from 18.5KW to 110KW, a standard built-in DC reactor is included. Models from 18.5KW to 37KW come with a built-in standard brake unit, while 45KW to 110KW models offer an optional built-in brake unit. The entire series benefits from an independent air duct design, which improves product reliability and performance.

2. Features

  • Excellent Control Performance: Achieves superior control through PG-free vector control mode, providing excellent motor drive and high-frequency operation capabilities.
  • Optimized Structure Design: Reduced product size saves installation space. Supports side-by-side guide rail installation for models up to 2.2KW.
  • Rich Configuration and Interface: Standard built-in 485 communication interface, with ample input/output terminals and an external keyboard interface for versatile field applications.
  • Power Factor Improvement: 18.5~110KW inverters include a standard built-in DC reactor.
  • Integrated Braking Unit: Standard built-in braking unit for models up to 37KW; optional for 45KW~110KW.
  • Various Installation Methods: Supports rail-mounted and wall-mounted installation for models up to 2.2KW; wall-mounted and flange-mounted for 4KW and above.
  • Easy Maintenance: The fan can be independently disassembled for convenient servicing.
  • Flexible Keyboards: Optional common LED external keyboard and an LED external keyboard with parameter copy function.
  • Integrated Functions: Includes Simple PLC, multi-speed control, built-in PID, torque control, multi-point V/F curve, multiple braking methods, and non-stop operation during instantaneous power failure.
  • Wide Application: Suitable for small and medium power applications in various industries such as food, plastic, ceramic, petroleum, cable, air compressors, machine tools, woodworking, textile, printing, packaging, chemical, and environmental protection equipment.

3. Specifications

The INVT Goodrive20 series offers various models with different power ratings and input/output characteristics. Below are detailed specifications for common models.

3.1 General Specifications

  • Name: INVT Goodrive20 Vector Inverter
  • Type: DC/AC Inverters
  • Origin: Mainland China
  • Certification: CE
  • is_customized: Yes
  • High-concerned chemical: None
  • Weight: Approximately 4kg (varies by model)

3.2 Model-Specific Electrical Parameters (Three-phase 380V)

Table detailing Goodrive20 inverter specifications for three-phase 380V models, including model number, voltage level, output power (kW), input current (A), and output current (A).
Figure 3.1: Goodrive20 Three-phase 380V Model Specifications
Goodrive20 Three-phase 380V Model Specifications
ModelVoltage LevelOutput Power (kW)Input Current (A)Output Current (A)
GD20-0R7G-4Three-phase 380V0.753.42.5
GD20-1R5G-41.55.04.2
GD20-2R2G-42.25.85.5
GD20-004G-4413.59.5
GD20-5R5G-45.519.514
GD20-7R5G-47.52518.5
GD20-011G-4113225
GD20-015G-4154032
GD20-018G-418.54738
GD20-022G-4225145
GD20-030G-4307060
GD20-037G-4378075
GD20-045G-4459892
GD20-055G-455128115
GD20-075G-475139150
GD20-090G-490168180
GD20-110G-4110201215

3.3 Model-Specific Electrical Parameters (Single-phase 220V & Three-phase 220V)

Table detailing Goodrive20 inverter specifications for single-phase 220V and three-phase 220V models, including model number, voltage level, output power (kW), input current (A), and output current (A).
Figure 3.2: Goodrive20 Single-phase 220V & Three-phase 220V Model Specifications
Goodrive20 Single-phase 220V & Three-phase 220V Model Specifications
ModelVoltage LevelOutput Power (kW)Input Current (A)Output Current (A)
GD20-0R4G-S2Single-phase 220V0.46.52.5
GD20-0R7G-S20.759.34.2
GD20-1R5G-S21.515.77.5
GD20-2R2G-S22.22410
GD20-0R4G-2Three-phase 220V0.43.72.5
GD20-0R7G-20.7554.2
GD20-1R5G-21.57.77.5
GD20-2R2G-22.21110
GD20-004G-241716

4. Safety Information

WARNING: Electrical Hazard. Only qualified personnel should install, operate, and maintain this equipment.

  • Always disconnect power before installation, wiring, or maintenance.
  • Wait at least 5 minutes after disconnecting power for capacitors to discharge. The inverter may display a 'DANGER 5 min' warning, indicating residual voltage. Verify voltage is zero before touching any components.
  • Ensure proper grounding of the inverter and motor.
  • Protect against overcurrent, short circuits, and ground faults.
  • Do not operate the inverter with damaged cables or components.
  • Keep the inverter free from dust, moisture, and corrosive gases.
  • Ensure adequate ventilation to prevent overheating.
  • Follow all local and national electrical codes and safety regulations.

5. Installation

The Goodrive20 series inverters offer flexible installation options depending on the model's power rating.

5.1 Mounting Options

  • Rail-mounted: Models up to 2.2KW (inclusive) support side-by-side guide rail installation.
  • Wall-mounted: Models up to 2.2KW (inclusive) support wall-mounted installation.
  • Wall-mounted and Flange-mounted: Models 4KW and above support both wall-mounted and flange-mounted installation.
Three INVT Goodrive20 inverters mounted on a DIN rail, demonstrating installation flexibility.
Figure 5.1: Goodrive20 Inverters Mounted on a DIN Rail
Rear view of two INVT Goodrive20 inverters, showing mounting points and guide rail compatibility.
Figure 5.2: Rear View with Mounting Points

5.2 Environmental Considerations

  • Ensure the installation location is clean, dry, and free from direct sunlight.
  • Maintain proper clearance around the inverter for adequate airflow and heat dissipation.
  • Avoid areas with excessive vibration, dust, or corrosive substances.

6. Wiring Diagrams

Correct wiring is critical for the safe and proper operation of the inverter. Refer to the following diagrams for main circuit and control circuit connections.

6.1 Main Circuit Wiring Diagram

Main circuit wiring diagram for Goodrive20 inverters, showing connections for single-phase 220V and three-phase 380V/220V inputs to motor outputs.
Figure 6.1: Main Circuit Wiring Diagram (3.2.1)

This diagram illustrates the main power connections for the Goodrive20 inverter. It shows configurations for:

  • Single-phase 220V input: Connects to L and N terminals, with PE for ground. Output U, V, W connect to the motor.
  • Three-phase 220V input: Connects to R, S, T terminals, with PE for ground. Output U, V, W connect to the motor.
  • Three-phase 380V input: Connects to R, S, T terminals, with PE for ground. Output U, V, W connect to the motor.

Braking resistors (制动电阻) and braking units (制动单元) are shown for energy dissipation during deceleration. Ensure all connections are secure and correctly phased.

6.2 Control Circuit Wiring Diagram

Control circuit wiring diagram for Goodrive20 inverters, illustrating connections for multi-function inputs, analog outputs, and RS485 communication.
Figure 6.2: Control Circuit Wiring Diagram (3.2.4)

This diagram details the connections for the control terminals, enabling various control functionalities:

  • Multi-function Inputs (S1, S2, S3, S4): Used for external control signals such as start/stop, jog, multi-speed selection.
  • High-speed Pulse Input (HDI): For high-frequency pulse signals.
  • Common (COM) and Power (PW): Reference and power supply for control signals.
  • Analog Inputs (AI2, AI3): For external analog signals (e.g., 0-10V, 4-20mA) to control frequency or other parameters.
  • Analog Outputs (AO1, AO2): Provide analog output signals (e.g., 0-10V, 0-20mA) for monitoring.
  • Relay Outputs (RO1A, RO1B, RO1C, RO2A, RO2B, RO2C): Programmable relay contacts for status indication or external device control.
  • RS485 Communication: Terminals for serial communication (485+, 485-, GND) for integration with control systems.

Refer to the inverter's parameter manual for detailed configuration of each control terminal function.

7. Operation

The Goodrive20 series inverters are designed for user-friendly operation with a robust control panel and extensive programmable functions.

7.1 Control Panel

Front view of the INVT Goodrive20 inverter with control panel, showing display and buttons.
Figure 7.1: Inverter Control Panel

The control panel typically includes:

  • Digital Display: Shows frequency, current, voltage, and other operational parameters.
  • Function Keys: PROG/ESC, DATA/ENT, UP, DOWN, SHIFT for parameter setting and navigation.
  • RUN/STOP Buttons: For starting and stopping the motor.
  • Potentiometer: For manual frequency adjustment.

7.2 Key Operational Functions

  • PG-free Vector Control: Provides precise speed and torque control without the need for a motor encoder.
  • Multi-speed Control: Allows pre-setting up to 16 different speeds, selectable via digital inputs.
  • Built-in PID: Integrated Proportional-Integral-Derivative controller for process control applications (e.g., pressure, flow, temperature).
  • Torque Control: Enables control of motor output torque.
  • Multi-point V/F Curve: Customizable voltage-to-frequency ratio for specific motor characteristics or load types.
  • Multiple Braking Methods: Includes DC braking and flux braking for controlled deceleration.
  • Non-stop in Instantaneous Power Failure: The inverter can maintain operation during brief power interruptions by utilizing the motor's inertia.
  • External Keyboard: An optional external LED keyboard can be used for remote operation and parameter copying.

For detailed parameter settings and programming, refer to the comprehensive programming manual provided by INVT.

8. Maintenance

Regular maintenance ensures the longevity and reliable operation of your INVT Goodrive20 inverter.

  • Cleaning: Periodically clean the inverter's exterior and cooling fins to prevent dust accumulation, which can impede heat dissipation. Use a soft, dry cloth.
  • Fan Inspection: The cooling fan is critical for heat management. Inspect it regularly for dust buildup or damage. The fan can be independently disassembled for easy cleaning or replacement.
  • Terminal Connections: Check all power and control terminal connections periodically to ensure they are tight and free from corrosion. Loose connections can cause overheating or intermittent operation.
  • Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges. Protect the inverter from moisture, corrosive gases, and excessive vibration.
  • Capacitor Check: While typically maintenance-free, large electrolytic capacitors have a finite lifespan. If the inverter shows signs of instability or reduced performance after several years, consider professional inspection of the capacitors.

Always disconnect power and wait for the 'DANGER 5 min' indicator to clear before performing any maintenance.

9. Troubleshooting

This section provides general guidance for common issues. For specific fault codes and detailed troubleshooting steps, refer to the full INVT Goodrive20 series manual.

  • No Power/Display: Check input power supply, fuses, and main circuit connections. Ensure the control power supply is active.
  • Motor Not Running: Verify RUN command, frequency setting, and motor wiring. Check for any fault indications on the display. Ensure motor parameters are correctly set in the inverter.
  • Overcurrent Fault: May be caused by sudden load changes, short circuits in motor wiring, or incorrect acceleration/deceleration times. Check motor and load conditions.
  • Overvoltage Fault: Often occurs during deceleration due to regenerative energy. Increase deceleration time or install an external braking resistor if not already present.
  • Undervoltage Fault: Check input power supply voltage.
  • Overheat Fault: Ensure proper ventilation, clean cooling fins and fan. Check ambient temperature.
  • Motor Noise/Vibration: Verify motor parameters (e.g., auto-tuning), motor wiring, and mechanical balance of the load.

If an issue persists after basic troubleshooting, contact qualified technical support.

10. User Tips

  • Parameter Backup: Utilize the parameter copy function of the optional external keyboard to save and restore settings, especially before making significant changes or for deploying multiple inverters with similar configurations.
  • Auto-tuning: For optimal motor performance, perform the auto-tuning function after initial installation and whenever the motor is changed. This helps the inverter learn the motor's electrical characteristics.
  • Cable Shielding: For control signals and communication lines, use shielded cables and ensure proper grounding of the shield to minimize electrical noise interference.
  • Load Matching: Ensure the inverter's power rating is appropriately matched to the motor and application load to prevent overloading or underutilization.
  • Software Updates: Periodically check the manufacturer's website for any firmware updates that may offer improved performance or new features.

11. Warranty and Support

The INVT Goodrive20 series inverter is covered by a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and distributor. Please retain your proof of purchase for warranty claims.

For technical support, service, or warranty inquiries, please contact your authorized INVT distributor or the manufacturer's customer service department. Provide the model number and serial number of your inverter when seeking assistance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.