1. Introduction
This manual provides essential information for the safe and efficient operation of your Hantek DSO2C10, DSO2C15, DSO2D10, and DSO2D15 Digital Portable Oscilloscope. Please read this manual thoroughly before using the device and keep it for future reference.
The Hantek DSO2000 series offers a cost-effective economy oscilloscope with a 150MHz bandwidth, 1GSa/s sample rate, and 8M memory depth. Models DSO2D10 and DSO2D15 include a 1-channel 25MHz waveform generator. These devices support various trigger modes, serial protocol decoding, auto measurements with statistics, and digital voltage meter functions.
2. Specifications
Below are the key specifications for the Hantek DSO2000 series models:
| Model | Channel | Bandwidth | Sample Rate | Memory Depth | AFG (Arbitrary Function Generator) |
|---|---|---|---|---|---|
| DSO2C10 | 2 CH | 100 MHz | 1 GSa/S | 8M | Without |
| DSO2C15 | 2 CH | 150 MHz | 1 GSa/S | 8M | Without |
| DSO2D10 | 2 CH+1CH | 100 MHz | 1 GSa/S | 1CH | |
| DSO2D15 | 2 CH+1CH | 150 MHz | 1 GSa/S | 1CH |
Additional Specifications:
- Battery Included: No
- High-concerned chemical: None
- Certification: CE
- Origin: Mainland China
- Digital Channels: 2
- Display Resolution: 800*480 Pixels
- Display Size: 7 Inches & Above
- Max Waveform Capture Rate: 30,000wfm/s
- Average waveform, times: 4, 8, 16, 32, 64, 128
- High resolution: Up to 12bit
- Input coupling: DC, AC, GND
3. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition:
- Hantek Digital Portable Oscilloscope Unit
- Power Cable
- USB Cables
- BNC Cables
- Oscilloscope Probes
- User Manual (Printed or Digital)
4. Setup
- Power Connection: Connect the provided power cable to the oscilloscope and a suitable power outlet.
- Initial Power On: Press the power button to turn on the device.
- Language Selection: If prompted, or to change the language, press the UTILITY button. Navigate through the options to select your preferred language (e.g., English or Chinese).
- Probe Connection: Connect the oscilloscope probes to the CH1 and CH2 input channels as needed for your measurements. Ensure a secure connection.
- Waveform Generator Connection (DSO2D10/DSO2D15 only): If using the built-in waveform generator, connect a BNC cable from the EXT TRIG/GEN OUT port to the circuit or device you wish to test.
5. Operating Instructions
This section outlines the basic operation of your Hantek oscilloscope.
5.1 Basic Waveform Display and Measurement
- Connect your probes to the circuit under test.
- Adjust the VERTICAL (Volts/Div) and HORIZONTAL (Sec/Div) knobs to scale the waveform appropriately on the screen.
- Use the AUTO SET button for automatic waveform scaling.
- The oscilloscope provides 32 kinds of auto measurements with statistics, including maximum, minimum, and standard deviation.
5.2 Decoding Functions
The oscilloscope supports standard 5 decoding functions for serial protocols:
- Press the DECODE button.
- A menu will appear on the screen, allowing you to select from UART, LIN, CAN, SPI, and IIC protocols.
- Choose the desired protocol for analysis.
5.3 Trigger Settings
To adjust trigger settings:
- Press the TRIGGER button.
- Use the on-screen menu and associated knobs to configure trigger modes such as Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, and Delay.
5.4 Waveform Generator (DSO2D10/DSO2D15 only)
For models with a built-in waveform generator:
- Ensure a cable is connected from the EXT TRIG/GEN OUT port to your target circuit.
- Press the WAVE GEN button.
- Use the controls to select the desired waveform type (e.g., sine, square, triangle) and adjust its frequency, amplitude, and offset.
5.5 Saving Data
The oscilloscope allows saving data in multiple formats:
- Settings
- Waveforms
- Reference waveforms
- CSV files
- Pictures
6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the oscilloscope. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity.
- Probe Care: Handle probes carefully. Avoid bending or stressing the cables excessively. Keep probe tips clean.
- Software Updates: Periodically check the manufacturer's website for any available firmware or software updates to ensure optimal performance and access to new features.
7. Troubleshooting
If you encounter issues with your oscilloscope, refer to the following common problems and solutions:
- Device does not power on:
- Ensure the power cable is securely connected to both the oscilloscope and a working power outlet.
- Check the power outlet with another device to confirm it has power.
- No waveform displayed:
- Verify that probes are correctly connected to both the oscilloscope input channels and the circuit under test.
- Check the probe settings (e.g., 1X/10X) match the oscilloscope's channel settings.
- Adjust the vertical (Volts/Div) and horizontal (Sec/Div) scales.
- Ensure the trigger settings are appropriate for the signal being measured. Try using the AUTO SET function.
- Inaccurate measurements:
- Perform a self-calibration if available in the utility menu.
- Ensure probes are properly compensated.
- Verify the signal source is stable and within the oscilloscope's measurement capabilities.
- Interface is unresponsive:
- Try restarting the device.
- Ensure no external devices are interfering with the USB connection if applicable.
8. User Tips
- For optimal signal integrity, always use the shortest possible ground lead on your probes.
- When measuring high-frequency signals, use 10X attenuation probes to minimize loading effects on the circuit.
- Familiarize yourself with the various trigger modes to capture specific events in your waveforms effectively.
- Utilize the serial protocol decoding functions to debug communication lines efficiently.
- Regularly save important waveform data and settings to a USB drive for analysis and record-keeping.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your vendor directly. Keep your proof of purchase for any warranty claims.
The manufacturer provides abundant SCPI remote command control for advanced users and integration into automated test systems.