1. Introduction
The OWON OW18D and OW18E are advanced 4 1/2 digit (20000 counts) handheld digital multimeters designed for precise electrical measurements. Both models feature True RMS testing, a built-in flashlight, and Non-Contact Voltage (NCV) detection. The OW18E model further enhances functionality with Bluetooth 4.0 wireless transmission, data logging capabilities, and a thermometer function, allowing for real-time data display, analysis, and sharing via a dedicated mobile/PC application.
This manual provides detailed instructions for the safe and effective use of your OWON digital multimeter.
2. Package Contents
Please check the package contents upon unboxing. If any items are missing or damaged, contact your vendor.
Figure 2.1: OWON Multimeter and Accessories
- OW Series Multimeter (OW18D or OW18E)
- 9V Battery (optional, check local regulations for inclusion)
- Screwdriver
- K-type Thermocouple (included with OW18E only)
- Alligator Clip
- Multimeter Lead (Red and Black)
- Instructions Manual (this document)
- App Installation Guide (included with OW18E only)
Product Dimensions: L: 196mm x W: 88.5mm x H: 56mm
Product Weight: Net weight 0.32 kg, Gross weight 0.55 kg
Packaging Size: L: 210mm x W: 132mm x H: 55mm
3. Product Overview
Familiarize yourself with the components of your OWON digital multimeter:
Figure 3.1: Front Panel Layout (OW18E shown)
- Flashlight: Illuminates the measurement area.
- LCD Display: Shows measurement readings, units, and function indicators.
- Bluetooth/Backlight Buttons: Activates Bluetooth connectivity (OW18E) and display backlight.
- Rotary Switch: Selects measurement functions (Voltage, Current, Resistance, etc.).
- Input Terminals:
- 20A Current Input Terminal: For high current measurements.
- V/Ω/Hz/(t/~)/→+/°C/°F Input Terminal: For Voltage, Resistance, Frequency, Diode, Continuity, and Temperature measurements.
- mA µA Input Terminal: For low current measurements.
- COM Input Terminal: Common ground for all measurements.
Figure 3.2: Back Panel and Additional Features
- Insulated Non-slip Case: Provides protection and grip.
- Test Lead Slot: Convenient storage for test leads.
- Retractable Stand: Allows for hands-free operation.
- Fuse and Battery Compartment: Houses the 9V battery and protective fuse.
- Protective Sleeve: Additional protection for the multimeter.
4. Setup
4.1 Battery Installation
The multimeter requires a 9V battery for operation. To install or replace the battery:
- Ensure the multimeter is turned OFF and all test leads are disconnected.
- Locate the battery compartment on the back of the device (refer to Figure 3.2).
- Use a screwdriver to open the battery compartment cover.
- Insert a new 9V battery, observing the correct polarity (+/-).
- Replace the cover and secure it with the screw.
4.2 Connecting Test Leads
Always connect the test leads correctly for accurate and safe measurements.
- Insert the black test lead into the "COM" (Common) input terminal.
- For most voltage, resistance, frequency, diode, continuity, and temperature measurements, insert the red test lead into the "V/Ω/Hz/(t/~)/→+/°C/°F" input terminal.
- For current measurements:
- For low currents (mA, µA), insert the red test lead into the "mA µA" input terminal.
- For high currents (up to 20A), insert the red test lead into the "20A" input terminal.
WARNING: Incorrect connection of test leads, especially for current measurements, can damage the multimeter or cause injury. Always ensure the rotary switch is set to the appropriate function before connecting leads to a circuit.
5. Operating Modes and Functions
The OWON multimeter offers a variety of measurement functions, selected using the rotary switch and function buttons.
5.1 Basic Measurements
- DC Voltage (V-): Turn the rotary switch to V-. Connect leads in parallel with the DC source.
- AC Voltage (V~): Turn the rotary switch to V~. Connect leads in parallel with the AC source.
- DC Current (µA-, mA-, 20A-): Turn the rotary switch to the desired DC current range. Connect leads in series with the circuit.
- AC Current (µA~, mA~, 20A~): Turn the rotary switch to the desired AC current range. Connect leads in series with the circuit.
- Resistance (Ω): Turn the rotary switch to Ω. Connect leads across the component. Ensure the circuit is de-energized.
- Diode Test (→+): Turn the rotary switch to →+. Connect leads across the diode.
- Continuity Buzzer (t/~): Turn the rotary switch to t/~. The buzzer sounds if resistance is below a certain threshold.
- Capacitance: Turn the rotary switch to the capacitance symbol. Connect leads across the capacitor. Ensure the capacitor is discharged before testing.
- Frequency (Hz): Turn the rotary switch to Hz. Connect leads to the signal source.
- Temperature (°C/°F) (OW18E only): Turn the rotary switch to °C/°F. Connect the K-type thermocouple to the input terminals. Press the Hz/% /°C/°F button to switch between Celsius and Fahrenheit.
5.2 Special Functions
- True RMS: Both OW18D and OW18E models feature True RMS measurement for accurate readings of non-sinusoidal AC waveforms.
- Auto Range: The multimeter automatically selects the appropriate measurement range.
- Auto Power Off (APO): The device will automatically power off after a period of inactivity to save battery.
- Flashlight: Press the flashlight button to illuminate the work area.
- Backlight: Press the backlight button to illuminate the LCD display.
- NCV (Non-Contact Voltage) Detection: Turn the rotary switch to NCV. Hold the top of the multimeter near a live AC voltage source. The strength indicator will light up, and an audible alarm may sound.
- Data Hold (H): Press the H/Duty /Δ/E button briefly to hold the current reading on the display. Press again to release.
- Duty Cycle (%): Available in certain AC measurement modes.
- Relative Measurement (Δ/E): Press and hold the H/Duty /Δ/E button to activate relative mode. The display will show the difference between the current reading and a stored reference value.
6. Bluetooth Functionality (OW18E Only)
The OW18E model features Bluetooth 4.0 for wireless data transmission to a mobile device or PC. This allows for advanced data logging, analysis, and sharing.
Figure 6.1: Bluetooth Connectivity and Real-time Measurement
6.1 App Installation
Refer to the "App Installation Guide" included in your package for detailed instructions on downloading and installing the OWON BLE Multimeter app on Android, iOS, or Windows devices. You can typically find the app by scanning the QR code provided or searching in your device's app store.
6.2 Connecting via Bluetooth
- Ensure Bluetooth is enabled on your mobile device or PC.
- Turn on the OW18E multimeter.
- Press the Bluetooth button on the multimeter to activate its Bluetooth module.
- Open the OWON BLE Multimeter app on your device.
- Follow the in-app instructions to search for and connect to your OW18E multimeter.
Note: A Bluetooth USB dongle (optional) may be required for PC connectivity if your computer does not have built-in Bluetooth.
6.3 Data Logging and Analysis
Figure 6.2: Data Logging Interface with Chart and Table View
The app allows you to:
- Record Measurements: Log measured values over time. The record interval can be adjusted (default > 0.5 seconds).
- Display Data: View recorded data in charts or tables for easy analysis of trends.
- Voice Broadcast: The app supports voice broadcast of measurements, allowing you to focus on your work without constantly looking at the display. Adjust speaking speed as needed.
- Simultaneous Measurement: Perform and compare multiple sets of data simultaneously.
6.4 Offline Recording Function
Figure 6.3: Offline Recording Setup and Data Download
The OW18E can record data even when disconnected from the mobile app:
- Set the sample interval (1 to 4,200,000 seconds) and the number of recording points (0 to 10,000 points) via the mobile app.
- Once configured, the multimeter can be disconnected from the mobile phone, and data will be saved in its internal memory.
- After recording is finished, reconnect to the mobile app to download the data from the meter's memory. If the battery is low, the meter will shut down for data protection before the data is downloaded.
6.5 Data Sharing
Figure 6.4: Sharing Measured Data
Measured data can be saved in CSV format via Bluetooth transmission. Users can recall the data in the software at any time for analysis and comparison. You can share the data to social media or other software directly from the app.
7. Maintenance
7.1 Cleaning
To clean the multimeter, wipe the case with a soft, damp cloth. Do not use abrasives or solvents. Ensure the device is off and disconnected from any circuits before cleaning.
7.2 Battery Replacement
Replace the 9V battery when the low battery indicator appears on the display. Refer to section 4.1 for battery installation instructions.
7.3 Fuse Replacement
If the current measurement function stops working, the fuse may need replacement. The fuse is located within the battery compartment (refer to Figure 3.2). Use only fuses of the specified type and rating to prevent damage and ensure safety.
WARNING: Always disconnect test leads and power off the multimeter before opening the battery/fuse compartment.
7.4 Storage
When not in use, store the multimeter in a dry, cool place. If storing for extended periods, it is recommended to remove the battery to prevent leakage.
8. Troubleshooting
- No Display/Power:
- Check if the battery is installed correctly and has sufficient charge. Replace if necessary.
- Ensure the rotary switch is not in the "OFF" position.
- Inaccurate Readings:
- Verify test lead connections are secure and in the correct terminals for the selected function.
- Ensure the rotary switch is set to the appropriate measurement function and range.
- Check for damaged test leads.
- For OW18E, ensure Bluetooth connection is stable if using the app for readings.
- Current Measurement Not Working:
- Check if the fuse is blown. Replace with a fuse of the correct rating (refer to section 7.3).
- Ensure the red test lead is in the correct current input terminal (mA µA or 20A).
- Bluetooth Connectivity Issues (OW18E only):
- Ensure Bluetooth is enabled on both the multimeter and your smart device.
- Make sure the multimeter is within range of your smart device.
- Restart both the multimeter and the app.
- Check app permissions on your smart device.
9. Specifications
The following table details the technical specifications for the OWON OW18D/OW18E multimeters:
Figure 9.1: Detailed Measurement Specifications
| Measurement | Range | Accuracy |
|---|---|---|
| DC Voltage | 20.000mV/200.00mV/2.000V/20.00V/200.0V/1000.0V | ±(0.05%+10 dig) to ±(0.15%+5 dig) |
| AC Voltage | 20.000mV/200.00mV/2.000V/20.00V/200.0V/750.00V | ±(0.5%+10dig) to ±(0.8%+10dig) |
| DC Current | 200.00uA/2.000mA/20.00mA/200.00mA/2.000A/20.000A | ±(0.5%+10dig) to ±(2.0%+10dig) |
| AC Current | 200.00uA/2.000mA/20.00mA/200.00mA/2.000A/20.000A | ±(0.8%+10dig) to ±(2.5%+10dig) |
| Resistance (Ω) | 200.0Ω/2.000kΩ/20.00kΩ/200.00kΩ/2.000MΩ/20.00MΩ/200.0MΩ | ±(0.5%+10dig) to ±(5.0%+10dig) |
| Capacitance (F) | 2.000nF/20.00nF/200.00nF/2.000uF/20.00uF/200.00uF/2.000mF/20.00mF | ±(3.0%+10dig) to ±(5.0%+10dig) |
| Frequency (Hz) | 200.00Hz/2.000kHz/20.00kHz/200.00kHz/2.000MHz/20.00MHz | ±(0.1%+4dig) |
| Duty Ratio | 0.1%~99.9% (typical value: Vrms=1V, f=1kHz) | ±(1.2%+3dig) to ±(2.5%+3dig) |
| Temperature (°C/°F) | -50°C ~ 400°C (0.1°C) -58°F ~ 752°F (0.1°F) |
±(1.0%+3°C) ±(1.2%+6°F) |
| Display | 19999 (4 1/2 digits) | |
| Frequency Response | (40 - 1000) Hz | |
| Sample Rate for Digital Data | 3 times/second | |
| Certification | CE, 1000V CAT III, 600V CAT IV | |
| Operating Mode | Auto Range | |
10. User Tips
- Safety First: Always ensure the multimeter is set to the correct function and range before connecting to any circuit. Never attempt to measure voltage or current beyond the specified limits.
- Battery Life: To extend battery life, remember to turn off the multimeter when not in use, or rely on the Auto Power Off (APO) function.
- Clear Readings: Use the backlight function in dimly lit environments for better visibility of the LCD display.
- OW18E App Usage: For the OW18E model, regularly check for app updates to ensure optimal performance and access to the latest features. Utilize the data logging and chart functions for long-term monitoring and trend analysis.
- Probe Care: Inspect test leads for any damage (cracks, frayed wires) before each use. Replace damaged leads immediately.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided by your original vendor or visit the official OWON website. Keep your purchase receipt as proof of purchase for warranty claims.