1. Introduction
The BSIDE U5 is a versatile and intelligent U-shaped clamp meter designed for a wide range of electrical measurements. It features a high-definition TFT screen for clear readings, True RMS measurement for accuracy, and auto-ranging capabilities for ease of use. Equipped with a built-in 1200mAh rechargeable battery, it offers convenient and worry-free operation. This multimeter combines the functions of a clamp meter, multimeter, and electric pen, making it an essential tool for electrical professionals and DIY enthusiasts.
Key features include:
- Automatic recognition and immediate testing upon startup.
- Beeping for connection and disconnection, breakpoint finding.
- Non-contact induced voltage.
- Identification of live and neutral wires.
- AC/DC current measurement.
- AC/DC voltage measurement.
- Capacitor/Diode testing.
- Automatic range, intelligent fire prevention.
- Flashlight lighting.
- Lithium battery charging via USB Type-C.
Video 1: BSIDE U5 Clamp Meter Product Demonstration
2. Product Overview
Familiarize yourself with the components of your BSIDE U5 Clamp Meter:

Figure 1: BSIDE U5 Clamp Meter Components
- Current sensing area
- Non-contact voltage sensing area
- Flashlight
- Display screen
- USB charging port
- Non-contact voltage sensing (V-Alert)/live wire identification/flashlight switch
- AC/DC current switching button
- Automatic mode button
- Power button
- Hold the key/Switch between Chinese and English keys
- Reset the DC base number/reset the data
- Left cut function key
- Right cut function key
- Input port
3. Setup and Initial Use
3.1. Charging the Battery
The BSIDE U5 is equipped with a built-in 3.7V 1200mAh lithium battery. Before first use, or when the battery indicator shows low power, charge the device using the provided USB Type-C cable.
- Locate the USB charging port (5) on the device.
- Unscrew the back cover counterclockwise by 90 degrees to access the charging port.
- Connect the Type-C cable to the meter and a suitable USB power source.
- A red indicator light will illuminate during charging. The light will turn off when fully charged.

Figure 2: Charging the BSIDE U5 Clamp Meter
3.2. Power On/Off
Press the Power button (9) to turn the device on or off. The device will perform a self-check upon startup.
4. Operating Instructions
The BSIDE U5 features an intelligent auto-ranging function, meaning it can automatically recognize and measure most parameters without manual range selection. Measurement can be carried out immediately upon startup.
4.1. Display Features
The LCD high-definition digital display provides clear and intuitive readings, even in dim light, thanks to its high-definition backlight.

Figure 3: High-Definition Digital Display
The device supports dual display on one screen, allowing simultaneous testing of voltage and frequency.

Figure 4: Dual Display Functionality
4.2. Measurement Functions
The BSIDE U5 offers a comprehensive set of measurement capabilities:
- AC/DC Current Measurement (Clamp): Use the U-shaped clamp jaw (1) to measure current without breaking the circuit. The 16mm large jaw design easily handles cables of various diameters up to 600A.
- AC/DC Voltage Measurement: Connect the test leads to the input ports (14) and the circuit to measure voltage.
- Resistance Measurement: Connect the test leads to the input ports (14) and the component to measure resistance.
- Capacitance Measurement: Connect the test leads to the input ports (14) and the capacitor to measure capacitance.
- Diode Test: Connect the test leads to the input ports (14) and the diode to check its forward voltage drop.
- Continuity Test: Connect the test leads to the input ports (14) to check for continuity. A buzzer will sound if continuity is detected.
- Frequency and Duty Cycle Measurement: The meter can measure frequency (Hz) and duty cycle (%).
- Non-Contact Voltage (NCV) Induction: Use the NCV sensing area (2) for safe, non-contact detection of AC voltage. The device supports both high and low sensitivity modes.
- LIVE Zero and Live Wire Identification: This function helps identify live and neutral wires, making power verification more convenient.

Figure 5: Current Measurement with Clamp Jaw

Figure 6: Current and Voltage Detection Examples

Figure 7: Various Measurement Demonstrations

Figure 8: NCV Voltage Induction
4.3. Button Functions
- Power Button (9): Turns the device on or off.
- Automatic Mode Button (8): Activates or deactivates automatic measurement mode.
- AC/DC Current Switching Button (7): Toggles between AC and DC current measurement modes.
- Zero Button (11): Resets the DC base number or clears data.
- Hold/Language Button (10): Short press to hold the current reading. Long press to switch between Chinese and English display languages.
- Left/Right Cut Function Keys (12, 13): Used for navigating menus or selecting specific functions.
- Flashlight Switch (6): Activates the built-in flashlight for working in dark environments.
5. Maintenance and Care
5.1. Battery Charging
As detailed in the Setup section, regularly charge the internal 1200mAh lithium battery using the Type-C USB port. Ensure the back cover is properly secured after charging.
5.2. Cleaning
Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents that could damage the casing or screen.
5.3. Storage
Store the clamp meter in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
5.4. Automatic Shutdown
The instrument features an automatic shutdown function. If there is no signal input for about 10 minutes, the instrument will automatically shut down to conserve battery life.
6. Troubleshooting
- Device does not power on:
- Check if the battery is charged. Connect the device to a charger and try again.
- Ensure the power button is pressed firmly.
- Incorrect readings:
- Ensure test leads are properly connected to the input ports and the circuit.
- Verify the correct measurement mode is selected (though auto-ranging should handle most).
- For current measurements, ensure the wire is correctly placed within the clamp jaw.
- Perform a "Zero" operation if measuring DC current to eliminate residual magnetism.
- Display is dim or unreadable:
- The device has a high-definition backlight. Ensure the battery is sufficiently charged.
- Language is not English:
- Long press the "Hold" button (10) to switch between Chinese and English display languages.
7. Specifications
The following table outlines the technical specifications of the BSIDE U5 Clamp Meter:

Figure 9: Product Specifications
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| 1. DC Voltage | |||
| Direct current voltage (mV) | 60.00mV | 0.01mV | ±(1.0% reading +3characters) |
| Dc voltage (V) | 600.0mV | 0.1mV | ±(0.8% reading +3characters) |
| 6.000V | 0.001V | ±(1.0% reading +3characters) | |
| 610V | 1V | ±(1.0% reading +3characters) | |
| 2. AC Voltage | |||
| Alternating voltage (mV) | 60.00mV | 0.01mV | ±(1.2% reading +3characters) |
| 600.0mV | 0.1mV | ±(1.2% reading +3characters) | |
| Alternating voltage (V) | 6.000V | 0.001V | ±(1.2% reading +5characters) |
| 610V | 1V | ±(1.2% reading +5characters) | |
| 3. Direct Current | |||
| Current | 1.0~600.0A | 0.1A | ±(2.5% reading +5characters) |
| 4. Alternating Current (Display frequency: ≥20A) | |||
| Range | 1~600.0A (40~999Hz) | 0.1A | ±(2.5% reading +5characters) |
| 5. Resistance | |||
| Range | 0.1Ω~599.9Ω | 0.1Ω | ±(1.2% reading +3characters) |
| 0.600KΩ~5.999KΩ | 0.001KΩ | ±(2.0% reading +10characters) | |
| 6.00MΩ~60.00MΩ | 0.01MΩ | ±(2.0% reading +10characters) | |
| 6. Capacitor | |||
| Range | 0.010uF~599.9uF | 0.1uF | ±(3.5% reading +8characters) |
| 0.600mF~60.0mF | 0.01mF | ±(4.5% reading +10characters) | |
| 7. Frequency (900mVrms to 20Vrms) | |||
| Range | 10.0Hz~99.9Hz | 0.001Hz, 0.1Hz | ±(2.0% reading +10characters) |
| 1.000KHz~99.9KHz | 0.001KHz, 0.1KHz | ±(2.5% reading +12characters) | |
| 1.000MHz~9.999MHz | 0.001MHz | ±(3.0% reading +15characters) | |
| 8. Duty Cycle | |||
| Range | 10.0%~95.0% | 0.1% | ±3.0% |
General Specifications:
- Battery Included: Yes
- Weight: 170g (Device only, approx. 146.5g as per diagram)
- Dimensions: 222.4mm * 43.6mm * 30mm (approx. 22*4*3 cm)
- Operating Temperature: 20-40°C
- Display Type: Digital Only
- Clamp Jaw: 16mm
- Origin: Mainland China
- DIY Supplies: Electrical

Figure 10: Dimensions and Weight
8. User Tips
- Language Setting: If the display language is not English, you can change it by long-pressing the "Hold" button (10).
- Clear Readings at Night: The LCD high-definition digital display with backlight ensures clear readings even in dim light conditions.
- Safety First: Always ensure proper insulation and follow electrical safety guidelines when performing measurements, especially with live circuits. The NCV and LIVE functions are designed for enhanced safety.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official BSIDE Tools Store or contact their customer service. Keep your purchase receipt as proof of purchase.