1. Introduction

This manual provides detailed instructions for the safe and effective use of your MESTEK CM87 Pro Series Digital Clamp Meter. This versatile tool is designed for professionals and DIY enthusiasts in power maintenance, electrical installation, and industrial testing. It offers a wide range of measurement capabilities including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature, along with advanced features like True-RMS, NCV, Inrush current measurement, and VFD.

2. Package Contents

Please check the package carefully to ensure all items are present and undamaged. If any items are missing or damaged, please contact your vendor.

Contents of the MESTEK CM87 Pro package including the clamp meter, test probes, K-type thermocouple, user manual, and carrying case.
Figure 2.1: MESTEK CM87 Pro Package Contents

The standard package includes:

  1. MESTEK CM87 Pro Digital Clamp Meter
  2. Test Probes (Red and Black)
  3. K-type Thermocouple (for CM87 Pro, CM87C, CM87B models)
  4. User Manual
  5. Instrument Storage Bag
  6. Packaging Box

For a visual guide to unboxing, please refer to the video below:

Video 2.1: MESTEK CM87 Pro Unboxing and Initial Overview

3. Product Overview

The MESTEK CM87 Pro series clamp meter features a robust design with a large jaw opening suitable for various cable diameters. It is equipped with a VA color screen for clear readings and a flashlight for working in low-light conditions.

Diagram showing the components of the MESTEK CM87 Pro clamp meter, including the NCV sensing area, current sensing zone, LED lamp, flashlight/data hold key, trigger, function knob, function switch key, VFD/INRUSH, ZERO, Max/Min switching, display, black probe, and red probe.
Figure 3.1: Appearance Introduction and Key Components

Key Components:

  • NCV Sensing Area: For non-contact voltage detection.
  • Current Sensing Zone: The clamp jaw for current measurement.
  • LED Lamp: Provides illumination.
  • Flashlight/Data Hold Key: Activates flashlight and holds data readings.
  • Trigger: Opens the clamp jaw.
  • Function Knob: Selects measurement modes.
  • Function Switch Key (SEL): Switches between functions within a mode (e.g., AC/DC, °C/°F).
  • VFD/INRUSH Button: Activates VFD or Inrush current measurement.
  • ZERO Button: Resets DC current reading to zero.
  • Max/Min Switching: Toggles between maximum and minimum recorded values.
  • Display: VA color screen for readings.
  • COM & INPUT Terminals: For connecting test probes.

4. Setup

4.1 Battery Installation

The device requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:

  1. Locate the battery compartment on the back of the meter.
  2. Open the battery cover.
  3. Insert two 1.5V AAA batteries, ensuring correct polarity (+/-).
  4. Close the battery cover securely.

A low battery indication (< 2.4V) will appear on the display when batteries need replacement.

5. Operation

5.1 General Safety Precautions

  • Always ensure the meter is in the correct function and range before making measurements.
  • Do not exceed the maximum input values for any function.
  • Inspect test leads for damage before use.
  • Avoid using the meter in wet environments or during electrical storms.
  • Wear appropriate personal protective equipment (PPE) when working with electricity.

5.2 AC/DC Current Measurement (1000A)

To measure AC or DC current:

  1. Rotate the function knob to the 'A' (Amperes) position.
  2. Press the trigger to open the clamp jaw.
  3. Place a single wire of the tested circuit at the center of the clamp head.
  4. Release the trigger to fully close the clamp. The instrument screen will display the current value.
Images demonstrating AC and DC current measurement using the clamp meter. The top image shows measuring AC current on a red wire in an electrical panel, displaying 23.69A. The bottom image shows measuring DC current on a car battery cable, displaying 09.38A.
Figure 5.1: AC and DC Current Measurement

5.3 AC/DC Voltage Measurement

The meter features AUTO-VLOZ for automatic recognition of AC/DC voltage.

  1. Rotate the function knob to the 'V' (Voltage) position.
  2. Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
  3. Connect the test probes across the circuit or component to be measured.
  4. The screen will automatically display the voltage value, identifying it as AC or DC.
Images showing AC and DC voltage measurement. The top image shows measuring AC voltage in an electrical panel, displaying 226.8V. The bottom image shows measuring DC voltage on a car battery, displaying 12.37V.
Figure 5.2: AC and DC Voltage Measurement

5.4 Resistance Measurement (0-60MΩ)

  1. Rotate the function knob to the 'Ω' (Ohm) position.
  2. Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
  3. Connect the test probes across the component to measure resistance.
  4. The display will show the resistance value.
Four images demonstrating various functions: Capacitance measurement on a capacitor, Resistance measurement on a resistor, Diode test on a diode, and Continuity test on a wire.
Figure 5.3: Resistance Measurement (part of multi-function display)

5.5 Capacitance Measurement (0-60mF)

  1. Rotate the function knob to the capacitance symbol (usually shared with resistance or diode). Press 'SEL' if needed to select capacitance.
  2. Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
  3. Connect the test probes across the capacitor.
  4. The display will show the capacitance value.
Four images demonstrating various functions: Capacitance measurement on a capacitor, Resistance measurement on a resistor, Diode test on a diode, and Continuity test on a wire.
Figure 5.4: Capacitance Measurement (part of multi-function display)

5.6 Frequency Measurement (0-10MHZ)

  1. Rotate the function knob to the 'Hz' (Frequency) position.
  2. Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
  3. Connect the test probes to the signal source.
  4. The screen will display the frequency value and the percentage of the measured signal.
Image showing the clamp meter measuring frequency, displaying 50.00 Hz, with test leads connected to an electrical circuit.
Figure 5.5: Frequency Measurement

5.7 Temperature Measurement (K-type probe)

Applicable for CM87 Pro, CM87C, CM87B models.

  1. Rotate the function knob to the temperature symbol (°C/°F).
  2. Connect the K-type thermocouple probe to the meter's input terminals.
  3. Place the thermocouple probe in contact with the object or liquid being measured.
  4. Press the 'SEL' key briefly to convert between Celsius (°C) and Fahrenheit (°F).
Image showing the clamp meter measuring temperature using a K-type thermocouple probe on a frozen fish in an industrial setting, displaying -005.9 °C.
Figure 5.6: Contact Temperature Measurement

5.8 Non-Contact Voltage (NCV) Detection

To detect AC voltage without contact:

  1. Rotate the function knob to the 'NCV' position.
  2. Bring the NCV sensing area of the instrument close to the circuit or conductor.
  3. Different alarm prompts (audible and visual) will sound according to the voltage intensity. The screen will display 'L' for low voltage or 'H' for high voltage and turn red.
Image showing the clamp meter detecting non-contact AC voltage. The left side shows 'Low Voltage' with a single red indicator, and the right side shows 'High Voltage' with multiple red indicators and a red screen.
Figure 5.7: Non-Contact AC Voltage Detection

5.9 LIVE Wire Recognition

To identify a live wire:

  1. Rotate the function knob to the 'LIVE' position.
  2. Use a test probe to touch the tested conductor.
  3. If it's a live wire, the red backlight will illuminate, and the buzzer will sound an alarm.
Image showing the clamp meter performing live wire recognition. A test probe is touching a wire, and the meter's screen is red with an 'H' indicating a live wire.
Figure 5.8: Live Wire Recognition

5.10 Diode Test

  1. Rotate the function knob to the diode symbol.
  2. Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
  3. Connect the test probes across the diode.
  4. The display will show the forward voltage drop.
Four images demonstrating various functions: Capacitance measurement on a capacitor, Resistance measurement on a resistor, Diode test on a diode, and Continuity test on a wire.
Figure 5.9: Diode Test (part of multi-function display)

5.11 Continuity Test

  1. Rotate the function knob to the continuity symbol (usually shared with resistance or diode). Press 'SEL' if needed to select continuity.
  2. Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
  3. Connect the test probes to the two points of the circuit or component to be tested.
  4. If continuity exists (low resistance), the buzzer will sound.
Four images demonstrating various functions: Capacitance measurement on a capacitor, Resistance measurement on a resistor, Diode test on a diode, and Continuity test on a wire.
Figure 5.10: Continuity Test (part of multi-function display)

5.12 Inrush Current Measurement

Applicable for CM87 Pro and CM87C models.

Inrush current is the maximum instantaneous input current drawn by an electrical device when first turned on.

  1. In AC current mode, press and hold the 'INRUSH' button.
  2. Before measuring, disconnect the load power supply.
  3. Place a single wire of the tested circuit at the center of the clamp head.
  4. Turn on the load power supply. The meter will capture and display the peak current.
Diagram illustrating inrush current waveform and an image of the clamp meter measuring inrush current on an industrial motor, displaying 106.9A.
Figure 5.11: Surge Current Measurement (Inrush)

5.13 Data Hold

To hold the current reading on the display:

  • Short press the 'HOLD' key (often combined with the flashlight button).
  • The display will freeze the current reading. A buzzer will sound every 2 seconds to indicate that data is held.
  • Press the 'HOLD' key again to release the data hold function.
Image showing the clamp meter with 'HOLD' activated, displaying a frozen reading of 12.09A in an electrical panel.
Figure 5.12: Data Hold Function

5.14 MAX/MIN Measurement

To record maximum and minimum values:

  • In AC/DC voltage or AC/DC current mode, press the 'MAX/MIN' button.
  • The meter will start recording the maximum and minimum values.
  • Press the button again to cycle through MAX, MIN, and current readings.
Image showing the clamp meter displaying a MAX/MIN measurement, with test leads connected to an electrical circuit, showing 227.1V.
Figure 5.13: MAX/MIN Measurement

5.15 DC Current Reset to Zero

To ensure accurate DC current measurements:

  • In DC current mode, long press the 'ZERO' key.
  • This eliminates any base number caused by magnetic field interference in the usage environment, providing more accurate results.
Two images showing the DC current zeroing function. The left image shows a reading of 00.39A before zeroing, and the right image shows 00.00A after zeroing.
Figure 5.14: DC Current Reset to Zero

5.16 VFD (Variable Frequency Drive) Measurement

Enabling VFD in AC voltage and current mode can effectively reduce interference of high-frequency signals on measurement results, providing more stable and accurate readings in environments with variable frequency drives.

  • Press the 'VFD' button when in AC voltage or AC current mode.
  • The meter will filter out high-frequency noise, displaying a more accurate reading for the fundamental frequency.

6. Maintenance

6.1 Cleaning

  • Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
  • Keep the terminals clean and free from dust and debris.

6.2 Storage

  • When not in use for extended periods, remove the batteries to prevent leakage.
  • Store the meter in its protective storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.

6.3 Calibration

The meter is factory calibrated. If you suspect inaccuracies, contact qualified service personnel for recalibration.

7. Troubleshooting

If the meter does not function properly, check the following:

  • No display or dim display: Check battery level and replace if necessary. Ensure batteries are installed correctly.
  • Incorrect readings: Ensure the function knob is set to the correct measurement mode and range. Check test leads for proper connection and damage. For DC current, perform a zero calibration.
  • No continuity beep: Ensure the meter is in continuity mode and test leads are properly connected. The resistance might be too high for the continuity threshold.
  • NCV not detecting: Ensure the NCV sensing area is close enough to the conductor. Check if the battery is low.
  • Meter not responding: Try turning the meter off and on again. If the issue persists, remove and reinsert batteries.

If problems persist after checking these points, contact customer support.

8. User Tips

  • Always prioritize safety. Before any electrical work, ensure you understand the circuit and take necessary precautions.
  • For current measurements, always clamp around a single conductor, not a bundle of wires, to get an accurate reading.
  • Utilize the data hold function when taking measurements in hard-to-reach or poorly lit areas to record the reading before moving the meter.
  • The flashlight feature is very useful in dark environments like electrical panels or under dashboards.
  • Remember to zero the DC current before taking sensitive DC current measurements to compensate for any residual magnetic fields.

9. Specifications

The following table outlines the key specifications for the MESTEK CM87 Pro series clamp meters. Note that specifications may vary slightly between models (CM87A, CM87B, CM87C, CM87 Pro).

Table comparing specifications for Digital Clamp Meter models CM87A, CM87B, CM87C, and CM87 Pro.
Figure 9.1: Digital Clamp Meter Parameter Comparison
MESTEK CM87 Series Digital Clamp Meter Specifications
FeatureCM87ACM87BCM87CCM87 Pro
DC Current✗✗0-600A0-1000A
AC Current0-600A0-600A0-600A0-1000A
K-type Temperature Probe✗✓✓✓
DC Voltage0-600V0-600V0-600V0-1000V
AC Voltage0-600V0-600V0-600V0-750V
Capacitance0-4mF0-60mF0-60mF0-60mF
Resistance0-40MΩ0-60MΩ0-60MΩ0-60MΩ
Inrush Current✗✗0-600A0-1000A
Display Counts3999599959995999
Operation RangeAuto rangeAuto rangeAuto rangeAuto range
Frequency Measure✗0-10MHZ0-10MHZ0-10MHZ
Overload Protection✓✓✓✓
Continuity Buzzer✓✓✓✓
Jaw Opening42mm42mm42mm42mm
True-RMS✓✓✓✓
Data Hold✓✓✓✓
Backlight✓✓✓✓
Auto Power Off✓✓✓✓
NCV✓✓✓✓
LIVE Wire Recognition✓✓✓✓
Diode✓✓✓✓
Input Impedance1MΩ1MΩ1MΩ1MΩ
Low Battery Indication< 2.4V< 2.4V< 2.4V< 2.4V
Battery2*1.5V AAA2*1.5V AAA2*1.5V AAA2*1.5V AAA

10. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your product or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.