1. Introduction
This manual provides detailed instructions for the safe and effective use of your MESTEK CM87 Pro Series Digital Clamp Meter. This versatile tool is designed for professionals and DIY enthusiasts in power maintenance, electrical installation, and industrial testing. It offers a wide range of measurement capabilities including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature, along with advanced features like True-RMS, NCV, Inrush current measurement, and VFD.
2. Package Contents
Please check the package carefully to ensure all items are present and undamaged. If any items are missing or damaged, please contact your vendor.

The standard package includes:
- MESTEK CM87 Pro Digital Clamp Meter
- Test Probes (Red and Black)
- K-type Thermocouple (for CM87 Pro, CM87C, CM87B models)
- User Manual
- Instrument Storage Bag
- Packaging Box
For a visual guide to unboxing, please refer to the video below:
3. Product Overview
The MESTEK CM87 Pro series clamp meter features a robust design with a large jaw opening suitable for various cable diameters. It is equipped with a VA color screen for clear readings and a flashlight for working in low-light conditions.

Key Components:
- NCV Sensing Area: For non-contact voltage detection.
- Current Sensing Zone: The clamp jaw for current measurement.
- LED Lamp: Provides illumination.
- Flashlight/Data Hold Key: Activates flashlight and holds data readings.
- Trigger: Opens the clamp jaw.
- Function Knob: Selects measurement modes.
- Function Switch Key (SEL): Switches between functions within a mode (e.g., AC/DC, °C/°F).
- VFD/INRUSH Button: Activates VFD or Inrush current measurement.
- ZERO Button: Resets DC current reading to zero.
- Max/Min Switching: Toggles between maximum and minimum recorded values.
- Display: VA color screen for readings.
- COM & INPUT Terminals: For connecting test probes.
4. Setup
4.1 Battery Installation
The device requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:
- Locate the battery compartment on the back of the meter.
- Open the battery cover.
- Insert two 1.5V AAA batteries, ensuring correct polarity (+/-).
- Close the battery cover securely.
A low battery indication (< 2.4V) will appear on the display when batteries need replacement.
5. Operation
5.1 General Safety Precautions
- Always ensure the meter is in the correct function and range before making measurements.
- Do not exceed the maximum input values for any function.
- Inspect test leads for damage before use.
- Avoid using the meter in wet environments or during electrical storms.
- Wear appropriate personal protective equipment (PPE) when working with electricity.
5.2 AC/DC Current Measurement (1000A)
To measure AC or DC current:
- Rotate the function knob to the 'A' (Amperes) position.
- Press the trigger to open the clamp jaw.
- Place a single wire of the tested circuit at the center of the clamp head.
- Release the trigger to fully close the clamp. The instrument screen will display the current value.

5.3 AC/DC Voltage Measurement
The meter features AUTO-VLOZ for automatic recognition of AC/DC voltage.
- Rotate the function knob to the 'V' (Voltage) position.
- Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
- Connect the test probes across the circuit or component to be measured.
- The screen will automatically display the voltage value, identifying it as AC or DC.

5.4 Resistance Measurement (0-60MΩ)
- Rotate the function knob to the 'Ω' (Ohm) position.
- Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
- Connect the test probes across the component to measure resistance.
- The display will show the resistance value.

5.5 Capacitance Measurement (0-60mF)
- Rotate the function knob to the capacitance symbol (usually shared with resistance or diode). Press 'SEL' if needed to select capacitance.
- Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
- Connect the test probes across the capacitor.
- The display will show the capacitance value.

5.6 Frequency Measurement (0-10MHZ)
- Rotate the function knob to the 'Hz' (Frequency) position.
- Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
- Connect the test probes to the signal source.
- The screen will display the frequency value and the percentage of the measured signal.

5.7 Temperature Measurement (K-type probe)
Applicable for CM87 Pro, CM87C, CM87B models.
- Rotate the function knob to the temperature symbol (°C/°F).
- Connect the K-type thermocouple probe to the meter's input terminals.
- Place the thermocouple probe in contact with the object or liquid being measured.
- Press the 'SEL' key briefly to convert between Celsius (°C) and Fahrenheit (°F).

5.8 Non-Contact Voltage (NCV) Detection
To detect AC voltage without contact:
- Rotate the function knob to the 'NCV' position.
- Bring the NCV sensing area of the instrument close to the circuit or conductor.
- Different alarm prompts (audible and visual) will sound according to the voltage intensity. The screen will display 'L' for low voltage or 'H' for high voltage and turn red.

5.9 LIVE Wire Recognition
To identify a live wire:
- Rotate the function knob to the 'LIVE' position.
- Use a test probe to touch the tested conductor.
- If it's a live wire, the red backlight will illuminate, and the buzzer will sound an alarm.

5.10 Diode Test
- Rotate the function knob to the diode symbol.
- Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
- Connect the test probes across the diode.
- The display will show the forward voltage drop.

5.11 Continuity Test
- Rotate the function knob to the continuity symbol (usually shared with resistance or diode). Press 'SEL' if needed to select continuity.
- Insert the red test lead into the 'INPUT' terminal and the black test lead into the 'COM' terminal.
- Connect the test probes to the two points of the circuit or component to be tested.
- If continuity exists (low resistance), the buzzer will sound.

5.12 Inrush Current Measurement
Applicable for CM87 Pro and CM87C models.
Inrush current is the maximum instantaneous input current drawn by an electrical device when first turned on.
- In AC current mode, press and hold the 'INRUSH' button.
- Before measuring, disconnect the load power supply.
- Place a single wire of the tested circuit at the center of the clamp head.
- Turn on the load power supply. The meter will capture and display the peak current.

5.13 Data Hold
To hold the current reading on the display:
- Short press the 'HOLD' key (often combined with the flashlight button).
- The display will freeze the current reading. A buzzer will sound every 2 seconds to indicate that data is held.
- Press the 'HOLD' key again to release the data hold function.

5.14 MAX/MIN Measurement
To record maximum and minimum values:
- In AC/DC voltage or AC/DC current mode, press the 'MAX/MIN' button.
- The meter will start recording the maximum and minimum values.
- Press the button again to cycle through MAX, MIN, and current readings.

5.15 DC Current Reset to Zero
To ensure accurate DC current measurements:
- In DC current mode, long press the 'ZERO' key.
- This eliminates any base number caused by magnetic field interference in the usage environment, providing more accurate results.

5.16 VFD (Variable Frequency Drive) Measurement
Enabling VFD in AC voltage and current mode can effectively reduce interference of high-frequency signals on measurement results, providing more stable and accurate readings in environments with variable frequency drives.
- Press the 'VFD' button when in AC voltage or AC current mode.
- The meter will filter out high-frequency noise, displaying a more accurate reading for the fundamental frequency.
6. Maintenance
6.1 Cleaning
- Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
- Keep the terminals clean and free from dust and debris.
6.2 Storage
- When not in use for extended periods, remove the batteries to prevent leakage.
- Store the meter in its protective storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
6.3 Calibration
The meter is factory calibrated. If you suspect inaccuracies, contact qualified service personnel for recalibration.
7. Troubleshooting
If the meter does not function properly, check the following:
- No display or dim display: Check battery level and replace if necessary. Ensure batteries are installed correctly.
- Incorrect readings: Ensure the function knob is set to the correct measurement mode and range. Check test leads for proper connection and damage. For DC current, perform a zero calibration.
- No continuity beep: Ensure the meter is in continuity mode and test leads are properly connected. The resistance might be too high for the continuity threshold.
- NCV not detecting: Ensure the NCV sensing area is close enough to the conductor. Check if the battery is low.
- Meter not responding: Try turning the meter off and on again. If the issue persists, remove and reinsert batteries.
If problems persist after checking these points, contact customer support.
8. User Tips
- Always prioritize safety. Before any electrical work, ensure you understand the circuit and take necessary precautions.
- For current measurements, always clamp around a single conductor, not a bundle of wires, to get an accurate reading.
- Utilize the data hold function when taking measurements in hard-to-reach or poorly lit areas to record the reading before moving the meter.
- The flashlight feature is very useful in dark environments like electrical panels or under dashboards.
- Remember to zero the DC current before taking sensitive DC current measurements to compensate for any residual magnetic fields.
9. Specifications
The following table outlines the key specifications for the MESTEK CM87 Pro series clamp meters. Note that specifications may vary slightly between models (CM87A, CM87B, CM87C, CM87 Pro).

| Feature | CM87A | CM87B | CM87C | CM87 Pro |
|---|---|---|---|---|
| DC Current | ✗ | ✗ | 0-600A | 0-1000A |
| AC Current | 0-600A | 0-600A | 0-600A | 0-1000A |
| K-type Temperature Probe | ✗ | ✓ | ✓ | ✓ |
| DC Voltage | 0-600V | 0-600V | 0-600V | 0-1000V |
| AC Voltage | 0-600V | 0-600V | 0-600V | 0-750V |
| Capacitance | 0-4mF | 0-60mF | 0-60mF | 0-60mF |
| Resistance | 0-40MΩ | 0-60MΩ | 0-60MΩ | 0-60MΩ |
| Inrush Current | ✗ | ✗ | 0-600A | 0-1000A |
| Display Counts | 3999 | 5999 | 5999 | 5999 |
| Operation Range | Auto range | Auto range | Auto range | Auto range |
| Frequency Measure | ✗ | 0-10MHZ | 0-10MHZ | 0-10MHZ |
| Overload Protection | ✓ | ✓ | ✓ | ✓ |
| Continuity Buzzer | ✓ | ✓ | ✓ | ✓ |
| Jaw Opening | 42mm | 42mm | 42mm | 42mm |
| True-RMS | ✓ | ✓ | ✓ | ✓ |
| Data Hold | ✓ | ✓ | ✓ | ✓ |
| Backlight | ✓ | ✓ | ✓ | ✓ |
| Auto Power Off | ✓ | ✓ | ✓ | ✓ |
| NCV | ✓ | ✓ | ✓ | ✓ |
| LIVE Wire Recognition | ✓ | ✓ | ✓ | ✓ |
| Diode | ✓ | ✓ | ✓ | ✓ |
| Input Impedance | 1MΩ | 1MΩ | 1MΩ | 1MΩ |
| Low Battery Indication | < 2.4V | < 2.4V | < 2.4V | < 2.4V |
| Battery | 2*1.5V AAA | 2*1.5V AAA | 2*1.5V AAA | 2*1.5V AAA |
10. Warranty and Support
For warranty information and technical support, please refer to the documentation included with your product or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.