The MPS-VX Series Hybrid Solar Inverter is a multi-functional inverter/charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications. This manual provides essential information for the safe and efficient operation of your MPS-VX Series Hybrid Solar Inverter.

Figure 1: MPS-VX Series Hybrid Solar Inverter
2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Installation must be performed by qualified personnel.
- Ensure proper grounding of the inverter.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (PV, battery, AC input) before performing any wiring or maintenance.
- Observe correct polarity when connecting batteries and solar panels.
3. Product Overview
3.1 Key Features
- Pure sine wave output
- Output power factor 1.0
- Programmable supply priority for PV, battery, or Grid
- User-adjustable charge current and voltage
- Wide PV input range (120Vdc-500Vdc), 110A MPPT Solar Charge Controller (SCC)
- Ability to work without batteries in sunny conditions
- WIFI Monitoring Function (optional)
- Anti-dusk kit for harsh environments (optional)
- LCD remote control with 5/10/20 meters wire (optional)
- PV and electricity complementary operation
- Compatible with lithium batteries
- Parallel operation up to 6 units
3.2 Components and Connections
The MPS-VX inverter features a user-friendly touch screen display and clearly labeled connection terminals.

Figure 2: Front Panel with Touch Screen Display and Control Buttons (ESC, UP, DOWN, ENTER)

Figure 3: Rear Panel Connections
Key Components:
- Touch Screen Display: Shows input/battery/temperature, output/load status, and protection indicators (Overtemperature, Overload, Short-circuit).
- Control Buttons: ESC, UP, DOWN, ENTER for menu navigation and setting adjustments.
- PV Input (+/-): Terminals for connecting solar panel arrays.
- AC Input (L, N, Ground): Terminals for connecting grid or generator AC power.
- AC Output (L, N, Ground): Terminals for connecting household loads.
- Battery Terminals (+/-): Connections for the battery bank.
- COM Port: For RS485/RS232 communication, or optional WIFI/LCD remote.
- Input Breaker: For AC input protection.
- ON/OFF Switch: Main power switch for the inverter.
- Cooling Fans: Located on the sides and top for thermal management.
Video 1: MPS-VX Series Hybrid Solar Inverter Product Overview
4. Setup
4.1 Unpacking and Inspection
Upon receiving your inverter, carefully unpack it and inspect for any shipping damage. Ensure all components listed in the packing list are present. If any damage or missing parts are found, contact your supplier immediately.
4.2 Mounting the Inverter
Mount the inverter vertically on a sturdy wall in a well-ventilated area. Ensure sufficient clearance (at least 20 cm) around the unit for proper airflow and heat dissipation. Avoid mounting in direct sunlight, near heat sources, or in areas with excessive dust or moisture. The operating temperature range is 0°C to 55°C, and humidity should be 5% to 95% relative humidity (non-condensing).
4.3 Wiring Connections
All wiring must comply with local and national electrical codes. Ensure all power sources are disconnected before making any connections.
- Battery Connection: Connect the positive (+) and negative (-) battery cables to the corresponding battery terminals on the inverter. Ensure correct polarity. Use appropriate cable gauges for the expected current.
- PV Connection: Connect the positive (+) and negative (-) cables from your solar panel array to the PV input terminals. Verify that the PV array's open circuit voltage and operating voltage are within the inverter's specified range (55-450VDC operating, 450VDC max open circuit).
- AC Input Connection: Connect the AC input from the utility grid or a generator to the AC Input terminals (L, N, Ground). Ensure an external input breaker is installed for protection.
- AC Output Connection: Connect your household loads to the AC Output terminals (L, N, Ground).
- Communication Connection (Optional): Connect RS485/RS232 cables for standard communication. If using optional WIFI monitoring or an LCD remote control, follow their respective installation guides.
4.4 Initial Power-Up
- After all connections are securely made and verified, switch on the external AC input breaker (if applicable).
- Switch on the battery breaker (if applicable).
- Switch on the PV array breaker (if applicable).
- Finally, press the ON/OFF switch on the inverter to power it on. The display will illuminate, and the inverter will begin its startup sequence.
5. Operating Instructions
5.1 Display and Button Operation
The inverter features a touch screen display for monitoring and configuration. Use the following buttons:
- ESC: Exit current menu or return to the previous screen.
- UP: Scroll up through menu options or increase values.
- DOWN: Scroll down through menu options or decrease values.
- ENTER: Confirm selection or enter a submenu.
The display provides real-time information on input voltage, battery status, temperature, output load, and active protection features.
5.2 System Settings
Navigate through the menu to configure various parameters:
- Output Source Priority: Set the priority for power supply (e.g., Solar first, Utility first, SBU priority).
- Charge Source Priority: Define which source (Solar, Utility, or both) charges the battery.
- Battery Type: Select the appropriate battery type (Flooded, AGM/GEL, Lithium) for optimized charging.
- Charging Current: Adjust the battery charging current based on battery specifications.
- Output Voltage Range: Configure the acceptable AC input voltage range for connected appliances.
5.3 Special Operating Modes
- Working Without Batteries: The inverter can supply power directly from PV to loads on sunny days, even without a connected battery bank.
- Parallel Operation: Up to 6 units can be connected in parallel to increase total power output. Refer to the dedicated parallel kit manual for detailed instructions.
- WIFI Monitoring (Optional): If equipped, use the dedicated mobile application to monitor system status and adjust settings remotely.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- Cleaning: Keep the inverter's exterior clean and free of dust. Regularly check and clean the ventilation openings and cooling fans to ensure unobstructed airflow. If operating in a harsh, dusty environment, consider installing the optional anti-dusk kit.
- Connections: Periodically inspect all wiring connections (PV, battery, AC input/output) for tightness, corrosion, or damage. Tighten any loose connections.
- Battery Maintenance: Follow the battery manufacturer's maintenance guidelines for your specific battery type. This may include checking electrolyte levels (for flooded batteries) or monitoring battery voltage.
- Environment: Ensure the installation environment remains within the specified temperature and humidity ranges.
7. Troubleshooting
This section provides guidance for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not power on | ON/OFF switch off, battery disconnected/low, input breaker tripped | Ensure ON/OFF switch is on. Check battery connections and voltage. Reset input breaker. |
| No AC output | Overload protection, short-circuit protection, battery low, PV input low | Reduce load. Check for short circuits. Check battery charge level. Verify PV input. |
| Over-temperature warning | Insufficient ventilation, high ambient temperature, blocked fans | Ensure adequate clearance around the inverter. Clean fan grilles. Reduce ambient temperature if possible. |
| Battery not charging | PV input too low, AC input not present, incorrect charging settings, faulty battery | Check PV voltage and current. Verify AC input. Review charging current and battery type settings. Test battery. |
8. Specifications
The following table details the technical specifications for the MPS-VX Series Hybrid Solar Inverter.

Figure 4: MPS-VX Series Specifications
| Feature | MPS-VX 4.5KW | MPS-VX 6.5KW |
|---|---|---|
| Rated Power | 4500W | 6500W |
| Voltage | 230VAC | |
| Selectable Voltage Range | 175-265VAC (personal computers) | 90-265VAC (home appliances) |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| Output AC Voltage Regulation (Batt. Mode) | 230VAC ±5% | |
| Surge power | 2*rated power for 5 seconds | |
| Efficiency (Peak) PV to INV | 97% | |
| Efficiency (Peak) BAT to INV | 94% | |
| Transfer Time | 10ms (personal computers) | 20ms (home appliances) |
| Wave form | Pure Sine Wave | |
| BATTERY & AC CHARGER | ||
| Battery Voltage | 24VDC | 48VDC |
| Bulk Charging Voltage (Flooded) | 29.2VDC | 58.4VDC |
| Bulk Charging Voltage (AGM/GEL) | 28.2VDC | 56.4VDC |
| Floating Charge Voltage | 27.6VDC | 54VDC |
| Overcharge Protection | 32VDC | 63VDC |
| Maximum charge current | 140A | 110A |
| SOLAR CHARGER | ||
| Max. PV Array Power | 7200W | |
| MPPT Range @ Operating Voltage | 55-450VDC | |
| Maximum PV Array Open Circuit Voltage | 450VDC | |
| Maximum Charging Current | 150A | 130A |
| Maximum Efficiency | 99% | |
| GRID-TIE OPERATION | ||
| PV INPUT (DC) Nominal DC Voltage/Maximum DC Voltage | 360VDC/450VDC | |
| Start-up Voltage/Initial Feeding Voltage | 55VDC | |
| MPPT Voltage Range | 55VDC-360VDC | |
| Number of MPPT Trackers/Maximum Input Current | 1/20A | |
| GRID OUTPUT (AC) | ||
| Nominal Output Voltage | 230VAC | |
| Output Voltage Range | 176V-264V | |
| Nominal Output Current | 19.5A | 28.2A |
| Power Factor | >0.99 | |
| Feed-in Grid Frequency Range | 49~51Hz | |
| EFFICIENCY | ||
| Maximum Conversion Efficiency (DC/AC) | 98% | |
| MPPT Efficiency | 99.90% | |
| PHYSICAL | ||
| Dimension, H*W*D(mm) | 400*250*89 | |
| Net Weight (kgs) | 7.5 | 8.5 |
| Communication Interface | RS485/RS232 (Standard)/LCD remote/WIFI (Optional) | |
| OPERATING ENVIRONMENT | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Operating Temperature | 0°C to 55°C | |
| Storage Temperature | -15°C to 60°C | |
9. User Tips
To maximize the performance and lifespan of your MPS-VX Series Inverter, consider the following:
- Battery Compatibility: Always ensure your battery type (Flooded, AGM/GEL, Lithium) is correctly selected in the inverter settings to prevent damage and ensure efficient charging.
- Ventilation is Key: Proper airflow is crucial. Regularly check that the inverter's fans and vents are not obstructed, especially in enclosed spaces.
- Monitor Performance: Utilize the built-in display or optional WIFI monitoring to keep track of your system's performance, battery state, and load. Early detection of anomalies can prevent larger issues.
- Load Management: Be mindful of the inverter's rated power and surge power capabilities. Avoid consistently running loads that push the inverter to its maximum capacity to prolong its life.
10. Warranty and Support
This product comes with a standard manufacturer's warranty. Please refer to your purchase documentation for specific warranty terms and conditions.
For technical support, inquiries, or assistance, please contact:
- Email: w17770950324@gmail.com
- WhatsApp: +86 17352870921
When contacting support, please have your product model (MPS-VX) and any relevant error messages or observations ready.