1. Introduction
This manual provides detailed instructions for the safe and effective use of your MESTEK 1000A AC/DC True RMS Auto Range Digital Clamp Meter. This versatile instrument is designed for various electrical measurements, including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature. It features True RMS, VFD, and INRUSH capabilities, making it suitable for power maintenance, electrical installation, and industrial testing.

2. Safety Information
Always adhere to safety precautions when using electrical testing equipment. Failure to do so may result in electric shock, injury, or damage to the meter or equipment under test.
- Ensure the meter is in good working condition before use.
- Do not exceed the maximum input values for any function.
- Use appropriate personal protective equipment (PPE).
- Avoid touching exposed conductors or circuit components.
- Do not operate the meter in wet environments or explosive atmospheres.
- Replace batteries promptly when the low battery indicator appears.
3. Product Overview and Setup
Familiarize yourself with the components of your clamp meter before operation.

3.1 Parts List

3.2 Battery Installation
The meter requires 2 x 1.5V AAA batteries. Ensure correct polarity when installing. The low battery indication will appear when the voltage drops below 2.4V.
3.3 Connecting Test Probes
Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack for voltage, resistance, capacitance, frequency, diode, and continuity measurements.
4. Operating Instructions
The MESTEK clamp meter offers a variety of measurement functions. Rotate the function knob to select the desired mode.
4.1 AC/DC Current Measurement (Clamp)
To measure current, place a single wire of the tested circuit at the center of the clamp head. Ensure the clamp is fully closed. The instrument screen will display the current value.

4.1.1 DC Current Zeroing
In DC current mode, long press the 'ZERO' key to eliminate any base number caused by magnetic field interference, ensuring more accurate measurement results.

4.2 AC/DC Voltage Measurement
Connect the test probes to the circuit. The meter will automatically identify whether the voltage is AC or DC and display the measured value.

4.2.1 AUTO-VLOZ (Automatic Voltage Recognition)
The instrument automatically identifies AC or DC voltage based on the measured signal.

4.3 Resistance Measurement
Connect the test probes across the component to measure resistance. The screen will display the resistance value in Ohms.

4.4 Capacitance Measurement
Connect the test probes across the capacitor to measure capacitance. The screen will display the capacitance value.

4.5 Frequency Measurement
The screen displays the frequency value of the tested signal source. The instrument synchronously displays the percentage of the measured signal.

4.6 Contact Temperature Measurement
When measuring objects or liquids, place the K-type thermocouple probe in contact with the object being measured and press the 'SEL' key briefly to convert between °C/°F.

4.7 Diode Test
Connect the test probes across the diode. The meter will display the forward voltage drop.

4.8 Continuity Buzzer
Connect the test probes across the circuit. If the resistance is below a certain threshold, the buzzer will sound, indicating continuity.

4.9 Non-Contact Voltage (NCV) Detection
When the NCV sensing area of the instrument is brought close to a circuit, different alarm prompts (audible and visual) will be sounded according to the voltage intensity. The screen will display 'L' for low voltage or 'H' for high voltage with a red backlight.

4.10 LIVE Wire Recognition
Use a probe to touch the tested conductor for detection. The red backlight is illuminated, the buzzer sounds an alarm, and the tested wire is identified as a live wire.

4.11 Data Hold (HOLD)
Short press the 'HOLD' key to lock the current measurement data on the display. The buzzer will sound a warning every 2 seconds to indicate the locked state.

4.12 MIN/MAX Measurement
This function allows locking test data in AC/DC voltage and AC/DC current modes to capture minimum and maximum values.

4.13 VFD (Variable Frequency Drive) Measurement
Enabling VFD in AC voltage and current mode can effectively reduce interference from high-frequency signals on measurement results.
4.14 INRUSH Current Measurement
Measures the initial surge current when a device is powered on (available on CM87C and CM87 Pro models).
4.15 Flashlight
The meter includes a built-in flashlight for illuminating dark work areas.

5. Maintenance
5.1 Cleaning
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
5.2 Battery Replacement
When the low battery indicator (less than 2.4V) appears on the display, replace the 2 x 1.5V AAA batteries immediately to ensure accurate readings.
5.3 Storage
If the meter is not used for a long period, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
6. Troubleshooting
If the meter does not function correctly, check the following:
- No display or dim display: Check battery level and replace if necessary. Ensure batteries are installed correctly.
- Inaccurate readings: Verify the correct function mode is selected. Ensure test leads are properly connected and not damaged. For DC current, perform a zeroing operation.
- No continuity beep: Check if the circuit is truly continuous and within the resistance threshold for the buzzer.
- NCV not detecting: Ensure the NCV sensing area is close enough to the AC voltage source.
If problems persist, contact MESTEK customer support.
7. Specifications
The following table outlines the technical parameters for the MESTEK Digital Clamp Meter models:

| Feature | CM87A | CM87B | CM87C | CM87 Pro |
|---|---|---|---|---|
| DC current | ✗ | ✗ | 0-600A | 0-1000A |
| AC current | 0-600A | 0-600A | 0-600A | 0-1000A |
| K type temperature probe | ✗ | ✓ | ✓ | ✓ |
| DC voltage | 0-600V | 0-600V | 0-600V | 0-1000V |
| AC voltage | 0-600V | 0-600V | 0-600V | 0-750V |
| Capacitance | 0-4mF | 0-60mF | 0-60mF | 0-60mF |
| Resistance | 0-40MΩ | 0-60MΩ | 0-60MΩ | 0-60MΩ |
| Inrush current | ✗ | ✗ | 0-600A | 0-1000A |
| Display counts | 3999 | 5999 | 5999 | 5999 |
| Operation range | Auto range | Auto range | Auto range | Auto range |
| Frequency measure | ✓ | 0-10MHZ | 0-10MHZ | 0-10MHZ |
| Overload protection | ✓ | ✓ | ✓ | ✓ |
| Continuity buzzer | ✓ | ✓ | ✓ | ✓ |
| Jaw opening | 42mm | 42mm | 42mm | 42mm |
| True-RMS | ✓ | ✓ | ✓ | ✓ |
| Data hold | ✓ | ✓ | ✓ | ✓ |
| Backlight | ✓ | ✓ | ✓ | ✓ |
| Auto power off | ✓ | ✓ | ✓ | ✓ |
| NCV | ✓ | ✓ | ✓ | ✓ |
| LIVE wire recognition | ✓ | ✓ | ✓ | ✓ |
| Diode | ✓ | ✓ | ✓ | ✓ |
| Input impedance | 1MΩ | 1MΩ | 1MΩ | 1MΩ |
| Low battery indication | < 2.4V | < 2.4V | < 2.4V | < 2.4V |
| Battery | 2*1.5V AAA | 2*1.5V AAA | 2*1.5V AAA | 2*1.5V AAA |
General Specifications:
- Dimensions: 218*75*39mm
- Weight: ~0.48kg (excluding battery)
- Operating Temperature: 0-40°C
- Storage Temperature: -10°C ~ 60°C
- Display Type: Digital Only
- Maximum Display Value: 5999 (for CM87B, CM87C, CM87 Pro) / 3999 (for CM87A)
- Over Range Display: OL or -OL
- Sample Time: About 3 times per second
- Automatic Shutdown Time: About 15 minutes
- Backlight Automatic Off Time: About 3 minutes
- Flashlight Automatic Shutdown Time: About 5 minutes
- Jaw Size: 30mm
- Certification: CE, FCC, RoHS
8. Warranty and Support
MESTEK products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official MESTEK website or contact your retailer. Keep your purchase receipt as proof of purchase.
9. User Tips
- Always start with the highest range: When measuring an unknown value, always select the highest range setting first and then decrease it if necessary to avoid overloading the meter.
- Check test leads: Before each use, visually inspect test leads for any damage or frayed insulation.
- Isolate power: Whenever possible, de-energize the circuit before making resistance, capacitance, or continuity measurements.
- Single wire for clamp: For current measurements with the clamp, ensure only one conductor passes through the jaw. Measuring multiple conductors will result in an inaccurate reading (or zero if currents are balanced).
- Use Data Hold: For measurements in hard-to-reach areas, use the 'HOLD' function to freeze the reading on the display for easier viewing.
- Mind the environment: Avoid using the meter in extreme temperatures or high humidity, as this can affect accuracy and safety.