Sumry SP Series

Contents

Sumry SP Series Off-Grid Solar Inverter Instruction Manual

Models: SP-2200, SP-3200, SP-4000, SP-7000

1. Introduction

This manual provides essential information for the safe and efficient operation of your Sumry SP Series Off-Grid Solar Inverter. The SP Series includes models with varying power capacities: 2200VA, 3200VA, 4200VA, and 7000VA. These high-frequency inverters convert DC power from solar panels and batteries into AC power for your appliances, featuring Maximum Power Point Tracking (MPPT) for optimized solar charging.

2. Safety Instructions

Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Installation must be performed by qualified personnel.
  • Ensure the inverter is installed in a well-ventilated area, away from flammable materials and moisture.
  • Do not disassemble the inverter. There are no user-serviceable parts inside.
  • Verify all wiring connections are secure and correctly polarized before powering on the unit.
  • Keep children away from the inverter and its connections.
  • Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.

3. Key Features

  • Pure sine wave output for sensitive electronics.
  • Programmable supply priority: PV, battery, or grid.
  • Wide PV input voltage range (55-450VDC).
  • Integrated MPPT solar charge controller (Max 110A for 3.6KW & 6.2KW models).
  • Compatibility with lithium-ion batteries and support for BMS communication.
  • Smart battery charge design to optimize battery life.
  • Comprehensive protection: overload, high temperature, inverter output short circuit.
  • Cold start function.
  • Intelligent fan speed adjustment for efficient cooling.
  • Optional built-in anti-dusk kit for harsh environments.
  • WIFI & GPRS monitoring available for iOS and Android (optional).

4. Technical Specifications

MODELSP-2200SP-3200SP-4000SP-7000
Rated Power2200VA/1800W3200VA/3000W4000VA/3600W7000VA/6200W
INPUT
Voltage230VAC
Selectable Voltage Range170-280VAC (for personal computers)
90-280VAC (for home appliances)
Frequency Range50Hz/60Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt.Mode)230VAC±5%
Surge power4400VA6400VA8000VA14000VA
Transfer Time10ms (for personal computers)
20ms (for home appliances)
Wave formPure Sine Wave
BATTERY & AC CHARGER
Battery Voltage12VDC24VDC24VDC48VDC
Floating Charge Voltage13.5VDC27VDC27VDC54VDC
Overcharge Protection15.5VDC31VDC31VDC61VDC
Maximum charge current60A80A
SOLAR CHARGER
MAX.PV Array Power2000W3000W5000W6000W
MPPT Range@ Operating Voltage55-450VDC
Maximum PV Array Open Circuit Voltage450VDC
Maximum Charging Current80A110A
Maximum Efficiency98%
PHYSICAL
Dimension.D*W*H(mm)405*286*98mm423*290*100mm423*310*120mm
Net Weight (kgs)4.5kg5.0kg7.0kg8.0kg
Communication InterfaceRS232/RS485 (Standard)
GPRS/WIFI (Optional)
OPERATING ENVIRONMENT
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10℃ to 55℃
Storage Temperature-15℃ to 60℃

5. Installation

The Sumry SP Series inverter is designed for wall-mounted installation. Ensure the mounting surface is strong enough to support the inverter's weight and that there is adequate clearance for ventilation. Professional installation is highly recommended.

5.1 Physical Overview

Front view of the Sumry SP Series Inverter
Figure 1: Front view of the Sumry SP Series Inverter
Rear view of the Sumry SP Series Inverter showing connection terminals
Figure 2: Rear view of the Sumry SP Series Inverter showing connection terminals
Side view of the Sumry SP Series Inverter showing communication ports
Figure 3: Side view of the Sumry SP Series Inverter showing communication ports

5.2 Wiring Connections

Refer to Figure 2 for the location of connection terminals. Ensure all connections are made according to local electrical codes and safety standards.

  • PV IN: Connect your solar panel array to these terminals. Observe correct polarity (+/-).
  • BATTERY: Connect your battery bank to these terminals. Ensure correct polarity (+/-) and proper battery voltage (12VDC, 24VDC, or 48VDC depending on model).
  • AC IN: Connect the utility grid power input here.
  • AC OUT: Connect your AC loads (appliances) to these terminals.
  • INPUT BREAKER: This is the main AC input circuit breaker.
  • COMM: Use this port for RS232/RS485 communication, and for optional WIFI/GPRS modules.

6. Operation

The inverter features an intuitive LCD display and control buttons for monitoring and configuration.

6.1 Control Panel and Display

Diagram of the inverter's LCD display and system flow
Figure 4: Inverter LCD Display and System Flow Diagram
Table explaining the inverter display icons and indicators
Figure 5: Explanation of Display Icons and Indicators

The control panel consists of an LCD display and several buttons: ESC, UP, DOWN, and ENTER. These buttons allow you to navigate through menus, view system status, and adjust settings.

6.2 Display Indicators Explained

Refer to Figure 5 for a detailed explanation of each icon and indicator on the LCD display:

  • PV input: Indicates power coming from solar panels.
  • AC input: Indicates power coming from the utility grid.
  • Input voltage, input frequency, PV voltage, battery voltage, charger current: Detailed electrical parameters.
  • Setting programs: Displays the current program number for configuration.
  • Flashing with warning code / Lighting with fault code: Alerts for system warnings or faults.
  • Output voltage, output frequency, load percent, load in VA, load in watt, and discharging current: Output parameters and load status.
  • Load level: Visual representation of the connected load.
  • DC/AC Inverter circuit is working: Indicates the inverter is actively converting power.
  • Battery level: Shows the current charge level of the battery.
  • Utility charger circuit is working: Indicates the inverter is charging batteries from the grid.
  • Unit connects to the PV panel: Confirms solar panel connection.
  • Unit connects to the mains: Confirms utility grid connection.
  • Load is supplied by utility power (BYPASS): Indicates power is bypassing the inverter directly from the grid.
  • Unit alarm is disabled: Shows if audible alarms are turned off.
  • Overload: Indicates the connected load exceeds the inverter's capacity.

6.3 System Operation Video

Watch this video for a visual guide on the manufacturing and testing process, which demonstrates the quality control and functionality of the inverters.

Video 1: Sumry Inverter Manufacturing and Testing Process

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter.

  • Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not blocked. If an optional anti-dusk kit is installed, follow its specific cleaning instructions.
  • Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Battery Health: Monitor battery voltage and performance. Ensure batteries are maintained according to their manufacturer's guidelines.
  • Environment: Ensure the installation environment remains within specified temperature and humidity ranges.

8. Troubleshooting

If you encounter issues with your Sumry SP Series inverter, refer to the display for any warning or fault codes (Figure 5). Common issues and general troubleshooting steps include:

  • No Power/Display Off: Check battery connections, PV input, and AC input. Ensure the input breaker is on.
  • No AC Output: Verify the inverter is not in fault mode (check display codes). Ensure loads are within the inverter's rated capacity. Check AC output wiring.
  • Overload Warning: Reduce the connected load. The inverter will typically attempt to restart after an overload condition is cleared.
  • High Temperature Warning: Ensure adequate ventilation around the inverter. Clear any obstructions from cooling fans.
  • Battery Not Charging: Check PV panel connections and voltage. Verify AC input is present if charging from the grid. Check battery health.

For persistent issues or complex fault codes, contact customer support.

9. User Tips

  • Regularly monitor the inverter's display for system status and any alerts to ensure continuous and efficient operation.
  • Optimize your programmable supply priority settings (PV, battery, or grid) based on your energy consumption patterns and local electricity rates to maximize savings and energy independence.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.