1. Introduction

This manual provides essential information for the safe and efficient operation of your East Tester ETP-B Series Single Channel DC Regulated Power Supply. These power supplies feature LED digital displays, programmable functions, and are designed for various applications requiring stable and adjustable DC power.

The ETP-B series offers program-controlled encoder adjustment, multiple protection features, and options for USB fast charging and various communication interfaces. They are characterized by low ripple, low noise, and intelligent temperature control.

Front view of East Tester ETP3010B DC Power Supply
Figure 1.1: Front view of an ETP3010B DC Power Supply.

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

  • Ensure the power supply is connected to a grounded outlet.
  • Do not operate the device in wet or damp conditions.
  • Do not open the casing; there are no user-serviceable parts inside. Refer servicing to qualified personnel.
  • Verify the input voltage matches the specified requirements (AC 220V±10%/50Hz or AC 110V±10%/60Hz).
  • Ensure proper ventilation to prevent overheating. Do not block the fan vent.
  • Always connect the load before turning on the power supply.
  • Use appropriate test leads and ensure they are in good condition.

3. Product Overview

3.1 Front Panel Description (ETP-B Series)

Front panel key description for ETP-B series DC Power Supply
Figure 3.1: Front Panel Key Description (ETP-B Series).
  • Voltage Display: Shows the output voltage in Volts (V).
  • Current Display: Shows the output current in Amperes (A).
  • Power Display: Shows the output power in Watts (W).
  • CC/CV Indicators: Constant Current (CC) and Constant Voltage (CV) mode indicators.
  • Power Switch: Main power ON/OFF button.
  • Output Negative Pole (-): Black terminal for negative load connection.
  • Protective Earth: Green terminal for grounding.
  • Output Positive Pole (+): Red terminal for positive load connection.
  • Current and Voltage Adjustment Knob: Rotary encoder for setting voltage and current values.
  • Left/Right Buttons: Navigation buttons for parameter selection.
  • M1, M2, M3: Quick parameter storage buttons.
  • V-Set: Button to enter voltage setting mode.
  • I-Set: Button to enter current setting mode.
  • Enter Key: Confirms settings or selections.

3.2 Rear Panel Description

Rear panel description of ETP DC Power Supply
Figure 3.2: Rear Panel Description.
  • Fan Vent: For cooling the internal components. Ensure it is not obstructed.
  • Power Outlet: AC power input connector.
  • Fuse Box: Contains the protective fuse.
  • RS232 Interface (Optional RS485): Serial communication port.
  • USB Interface (Optional): USB communication port for PC control or fast charging.

4. Setup

4.1 Unpacking

Carefully unpack the power supply and check for any signs of damage. Retain the packaging for future transport or storage. The typical packing list includes:

Packing list for ETP DC Power Supply
Figure 4.1: Typical Packing List.
  1. Power host (the DC power supply unit)
  2. Quality Certificate
  3. Instruction Manual (this document)
  4. Test line (output cables)
  5. Power plug (AC input cable)

4.2 Connecting Power

  1. Ensure the power switch on the front panel is in the OFF position.
  2. Connect the provided power plug to the power outlet on the rear panel of the device.
  3. Plug the other end of the power cable into a suitable AC power source (220V or 110V, depending on your model and region).

4.3 Connecting Load

  1. Ensure the power supply is OFF.
  2. Connect the positive (+) terminal of your load to the red output positive pole on the power supply.
  3. Connect the negative (-) terminal of your load to the black output negative pole on the power supply.
  4. If grounding is required for your application, connect the protective earth terminal to your system's ground.
  5. Ensure all connections are secure to prevent accidental disconnections during operation.

5. Operating Instructions

5.1 Power On/Off

  • To turn ON: Press the red power switch button on the front panel. The LED displays will illuminate.
  • To turn OFF: Press the red power switch button again. The displays will turn off.

5.2 Setting Voltage and Current

The ETP-B series uses an encoder knob and dedicated buttons for precise setting.

  1. Setting Voltage:
    • Press the 'V-Set' button. The voltage display will start blinking, indicating it's in setting mode.
    • Use the Left/Right buttons to select the digit you wish to adjust.
    • Rotate the Current and Voltage Adjustment Knob to change the value of the selected digit.
    • Press the 'Enter' key to confirm the voltage setting.
  2. Setting Current:
    • Press the 'I-Set' button. The current display will start blinking.
    • Use the Left/Right buttons to select the digit you wish to adjust.
    • Rotate the Current and Voltage Adjustment Knob to change the value of the selected digit.
    • Press the 'Enter' key to confirm the current setting.

5.3 Quick Parameter Storage (M1, M2, M3)

The device allows you to store and recall up to three frequently used voltage and current settings.

  • To Store: Set the desired voltage and current. Press and hold one of the 'M1', 'M2', or 'M3' buttons until a confirmation (e.g., a beep or display flash) indicates the parameters are saved.
  • To Recall: Briefly press the 'M1', 'M2', or 'M3' button corresponding to the saved setting you wish to recall. The power supply will automatically adjust to the stored values.

5.4 Constant Current (CC) and Constant Voltage (CV) Modes

The power supply automatically switches between Constant Voltage (CV) and Constant Current (CC) modes depending on the load and your set parameters.

  • CV Mode: When the load resistance is high, the output voltage will remain at the set value, and the output current will be determined by the load. The 'CV' indicator will be lit.
  • CC Mode: When the load resistance is low, causing the current to reach the set limit, the output current will remain at the set value, and the output voltage will drop. The 'CC' indicator will be lit. This protects both the power supply and the load.

6. Specifications

The following tables detail the technical specifications for the ETP-A and ETP-B series DC Regulated Power Supplies.

6.1 ETP-A Series Specifications

Index ETP1503A ETP1506A ETP3003A ETP3005A ETP3010A ETP6003A ETP6005A
Output voltage 0~15V 0~15V 0~30V 0~30V 0~30V 0~60V 0~60V
Output current 0~3A 0~6A 0~3A 0~5A 0~10A 0~3A 0~5A
Output power 45W 90W 90W 150W 300W 180W 300W
Steady state Voltage stability ≤0.1%+3mV; Load stability: ≤0.1%+3mA
Steady flow Current stability ≤0.1%+3mV; Load stability: ≤0.1%+3mA
Display accuracy Voltage: 0.5%+3 bits; Current: 0.5%+3 bits
Ripple and noise VPP≤1%
Display resolution Voltage: up to 10mV; Current: up to 1mA; Power: up to 10mW
Display method 4-bit red LED Nixie tube, 0.40 inch
Power input AC 220V±10%/50Hz or AC 110V±10%/60Hz (Users need to explain when purchasing)
Operating environment Indoor use, altitude: < 2000m, temperature: 5-40 °C, humidity: 10-85% RH
Storage environment Temperature: -20-80 °C, humidity: < 80% RH
Product size 190mm* 70mm* 130mm (Length * width * height)
Product weight Net weight: 1.1kg

6.2 ETP-B Series Specifications

Index ETP1506B ETP1520B ETP3005B ETP3010B ETP6003B ETP6005B ETP10003B ETP15002B
Output voltage 0~15V 0~15V 0~30V 0~30V 0~60V 0~60V 0~100V 0~150V
Output current 0~6A 0~20A 0~5A 0~10A 0~3A 0~5A 0~3A 0~2A
Output power 90W 300W 150W 300W 180W 300W 300W 300W
Steady state Voltage stability ≤0.1%+3mV; Load stability: ≤0.1%+3mA
Steady flow Current stability ≤0.1%+3mV; Load stability: ≤0.1%+3mA
Display accuracy Voltage: 0.5%+3 bits; Current: 0.5%+3 bits
Ripple and noise VPP≤1%
Display resolution Voltage: up to 10mV; Current: up to 1mA; Power: up to 10mW
Display method 4-bit red LED Nixie tube, 0.56 inch
Power input AC 220V±10%/50Hz or AC 110V±10%/60Hz (Users need to explain when purchasing)
Operating environment Indoor use, altitude: < 2000m, temperature: 5-40 °C, humidity: 10-85% RH
Storage environment Temperature: -20-80 °C, humidity: < 80% RH
Product size 190mm* 115mm* 150mm (Length * width * height)
Product weight Net weight: 1.3kg
Specifications table for ETP-A and ETP-B series DC Power Supplies
Figure 6.1: Detailed Specifications for ETP-A and ETP-B Series.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the power supply. Do not use abrasive cleaners or solvents.
  • Ventilation: Regularly check that the fan vents on the rear panel are clear of dust and obstructions to ensure proper cooling.
  • Fuse Replacement: If the power supply does not turn on, check the fuse in the fuse box on the rear panel. Replace it with a fuse of the same type and rating if necessary. Always disconnect the power cable before replacing the fuse.
  • Storage: When not in use for extended periods, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Troubleshooting

Problem Possible Cause Solution
No power/display off Power cable not connected, power outlet faulty, fuse blown. Check power cable connection. Test power outlet. Replace fuse if blown (refer to Maintenance section).
No output voltage/current Output terminals not connected, voltage/current set to zero, OVP/OCP triggered. Ensure load is correctly connected. Verify voltage/current settings are above zero. Check for any protection indicators (if available) and reset if necessary.
Output voltage/current unstable Loose connections, faulty load, operating outside specified environment. Check all connections. Test with a different load. Ensure operating environment is within specifications.
Overheating Blocked fan vent, excessive ambient temperature, continuous high load. Clear fan vent. Move to a cooler environment. Reduce load or allow for cooling periods.

9. User Tips

  • Pre-set Limits: Always set your desired voltage and current limits before connecting a sensitive load to prevent accidental damage.
  • Monitor CC/CV: Pay attention to the CC/CV indicators to understand if your load is drawing more current than set (CC mode) or if the voltage is being maintained (CV mode).
  • Use Quick Storage: Utilize the M1, M2, M3 buttons to save frequently used settings for quick recall, especially for repetitive tasks.
  • Ventilation is Key: Ensure adequate airflow around the unit, especially the rear fan, to maintain optimal performance and longevity.

10. Warranty and Support