1. Product Overview
The Jiayin JYPC-4 is an electromagnetic pump designed for various household appliances, including steamers and steam mops. It features a compact design, low noise operation, and a sealed construction for reliability.

Figure 1: Jiayin JYPC-4 Electromagnetic Pump
Video 1: Demonstration of the JYPC-4 pump's physical appearance and operation.
2. Safety Instructions
Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Power-Off Operation: Always disconnect the power supply before performing any maintenance, installation, or troubleshooting on the pump.
- No Dry Running: Do not operate the pump without liquid. Dry running can cause severe damage to the pump components.
- Liquid Only: Use only clean, particle-free liquid with this pump to prevent clogging and damage.
- Choking Hazard: This product contains small parts. Keep out of reach of children under 3 years of age.
3. Installation
Proper installation is crucial for the optimal performance and longevity of your electromagnetic pump.
- Vertical Mounting: Ensure the pump is installed in a stable and upright position to prevent operational issues.
- Inlet/Outlet Sealing: Securely seal all inlet and outlet connections to prevent liquid leakage during operation.
- Inlet Filtration: Install a suitable filter at the pump's inlet to remove impurities from the liquid, protecting the pump from damage and clogging.
Wiring Diagram and Dimensions

Figure 2: Wiring Diagram and Dimensions of JYPC-4 Pump
Refer to Figure 2 for detailed wiring connections and physical dimensions to ensure correct integration into your appliance.
4. Operation
The JYPC-4 electromagnetic pump is designed to be integrated into household appliances such as steamers and steam mops. Its operation is typically controlled by the host appliance's system.
- Ensure the pump is correctly installed and connected to the power supply as per the wiring diagram.
- Verify that there is a sufficient supply of clean, particle-free liquid to the pump's inlet.
- Operate the host appliance according to its specific user manual. The pump will activate automatically when required by the appliance's function (e.g., steam generation).
5. Maintenance
Regular maintenance helps ensure the longevity and efficient operation of your pump.
- Filter Cleaning: Periodically check and clean the inlet filter to prevent blockages and maintain optimal flow.
- Seal Inspection: Inspect seals and tubing connections regularly for any signs of wear or damage. Replace seals and tighten tubing as necessary to prevent leaks.
- Pump Cleaning: If the pump's performance degrades, it may require internal cleaning. This should ideally be performed by a qualified technician.
6. Troubleshooting
If you encounter issues with your JYPC-4 pump, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| No Liquid Output | Air in pump, clogged filter, no power supply. | Bleed air from the system, clean the inlet filter, or check the power supply connections. |
| Low Pressure | Worn seals, loose tubing, debris in pump. | Replace seals, tighten tubing connections, or remove any debris from the pump. |
| Excessive Noise | Loose mounting, internal debris, worn plunger. | Reinforce pump mounting, clean the pump internally, or replace the plunger if worn. |
7. Specifications
Detailed technical specifications for the Jiayin JYPC-4 Electromagnetic Pump:
| Feature | Specification |
|---|---|
| Model Number | JYPC-4 |
| Power Source | Electric |
| Theory | Electromagnetic Pump |
| Structure | Self-Priming Pump |
| Standard or Nonstandard | Standard |
| Pressure | Low Pressure |
| Origin | China Mainland |
| Certification | CE |
| Voltage | 220-240V |
| Power | 22W |
| Maximum Pressure | 2.5 bar |
| Average Flow Rate | 200 cc/min |
| Noise Level | 54 dB |
| Material | Cast Steel |
| Drive Mode | Electric |
Performance Curves

Figure 3: Performance Curves (Flow/Pressure, Flow/Time, Temperature Rise/Time)
8. User Tips
- For optimal performance, ensure the water reservoir of your appliance is always filled with distilled or demineralized water to prevent mineral buildup in the pump.
- If the pump is being replaced, carefully note the orientation and connections of the old pump before removal to ensure correct installation of the new unit.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your specific appliance or contact the manufacturer of the appliance directly. This pump is a component part, and its warranty may be covered under the host appliance's warranty.
A detailed user manual in PDF format is available for download: Jiayin JYPC-4 Electromagnetic Pump User Manual (PDF)