1. Introduction
The Coolmay EX3U-8070H-44MRT is a 7-inch HMI (Human Machine Interface) and PLC (Programmable Logic Controller) all-in-one integrated controller. This device combines the functionality of a PLC and an HMI touch panel into a single unit, offering a compact and efficient solution for industrial automation applications. It supports RS232 and RS485 communication protocols and is designed for programming and control tasks.
Key advantages of this all-in-one machine include:
- High Performance: Equipped with a military-grade 32-bit CPU + ASIC dual processor, offering a fast execution speed of 0.24µs for basic instructions.
- Enhanced Security: Features separate encryption for HMI and PLC, with a PLC login keyword (12345678) to prevent unauthorized reading of ladder diagram programs.
- Extensive Capacity: PLC program capacity of 30K steps and 12K power-off retention registers. Supports programming in instruction list, ladder diagram (LD), and step ladder diagram (SFC).
- Versatile Communication: Compatible with Delta DVP programming port protocol, Modbus RTU, Modbus ASCII, and free port protocols, enabling easy interconnection with external devices.
- Advanced Control: Supports multiple interrupts (input, timer, communication, high-speed counter, pulse output) and motion positioning functions, including 2 groups of linear and circular interpolation (4-axis linkage) with high precision.
- Connectivity: Includes 1 HMI download port, 2 PLC programming ports (RS232/Mini B USB/Type-C), 1 RS485 port, and 1 USB 2.0 port. Optional network, CAN, or WiFi ports are available.
- Analog I/O: Supports multiple analog voltage and current mixed inputs and outputs (4 inputs, 2 outputs).
- Flexible Outputs: The EX3U-8070H/HD series offers a maximum of 24 inputs and 20 outputs (MR max 16), with output types selectable from relay (MR, max load 5A), transistor (MT, max load 500mA), or mixed relay/transistor (MRT).
- Easy Installation: All wiring terminals are 3.81 pitch pluggable terminals for convenient connection.
This manual provides detailed instructions for setting up, operating, and maintaining your Coolmay EX3U-8070H-44MRT controller.

Figure 1: Front view of the Coolmay EX3U-8070H-44MRT HMI PLC all-in-one controller.

Figure 2: Rear view of the Coolmay EX3U-8070H-44MRT showing various ports and terminals.
2. Specifications
2.1 General Specifications
- Brand Name: Coolmay
- Model Number: EX3U-8070H-44MRT
- Origin: Mainland China
- Certification: CE
- EU LVD Voltage: Low voltage: Below 50Vac or 75Vdc
- High-concerned chemical: None
- Motor: Stepper Motor
2.2 Detailed Product Parameters (EX3U-8070H/HD)
| Category | Parameter | Value |
|---|---|---|
| General | Dimensions | 200 * 146 * 36 mm |
| Cutout Size | 192 * 138 mm | |
| Weight | 0.65 kg | |
| Input Power | 24VDC, 6-7W | |
| HMI (Touch Screen) | Feature | 60K colors resistive touch screen, supports portrait display |
| Type | 7.0" TFT | |
| Display Size | 154 * 87 mm | |
| Resolution | 800 * 480 / 1024 * 600 | |
| RAM | 128MB / 256MB | |
| ROM | NAND Flash 128MB / 256MB | |
| HMI Processor | CPU | Dual core 1GHz |
| Operating System | Linux-based | |
| HMI Ports | COM Ports | Type-C HMI download port (can download PLC program through USB penetrating function), RS232 |
| USB | 1 USB 2.0 port | |
| Network Port | Optional 1 network port (cannot coexist with PLC network port) | |
| PLC I/O | I/O Points | Up to 24DI 20DO (MR 16, Y20-Y23 fixed as MT) |
| Input Level | Passive NPN, common terminal isolation | |
| Output Level | MT: Low level NPN, COM connected to negative; MR: Normally open dry contact | |
| DO Type and Load | MOS tube: 2A/point, 4A/4 points COM; MT: 0.5A/point, 0.8A/4 points COM, 1.6A/8 points COM; MR: 2A/point, 4A/4 points COM, 5A/8 points COM, 5A/12 points COM. | |
| High-Speed | Counting Input | Conventional 6-way single-phase 60KHz or 2-way AB(Z) phase 30KHz + 1-way AB phase 5KHz |
| Pulse Output | High-Speed Pulse Output | MT output: conventional 10 channels Y0-Y11 200KHz |
| Analog Interface | Input Type | Negative Temperature Thermocouple (E, K, S, T, J) / PT100 / PT1000 / NTC10K / NTC50K / NTC100K / 0-10V / 0-5V / 0-20mA / 4-20mA or hybrid type, etc. |
| Output Type | 0-10V / 0-5V / 0-20mA / 4-20mA / -5-5V / -10-10V (1 negative voltage accounts for 2 DA channels) | |
| Points | Up to 16 inputs and 8 outputs (Up to 8 isolated analog inputs (AD5-AD12) can be selected) | |
| Weighing | Optional installation of 2 or 4 weighing channels (cannot coexist with analog input) | |
| PLC Communication | Default | 1 TYPE-C programming port; default 1 RS232 + 1 RS485 |
| Optional | 1 RS485 (cannot coexist with the RS485 selected by the screen and the RS232 defaulted by the PLC) | |
| Other | Optional CAN port (2.0A/B), network port (cannot coexist with touch screen network port); Optional WIFI (will occupy the touch screen download port) | |
| Software | Programming Software | Coolmay VTool Pro, Compatible with GX Developer 8.86Q and GX Works2 |
3. Setup and Installation
3.1 Component Overview
Familiarize yourself with the various interfaces and indicator lights on the device:
- POWER Indicator: Illuminates when power is connected.
- RUN Indicator: Indicates PLC running status (on when PLC is running).
- COM Indicator: Indicates touch screen and PLC communication status (on when communicating).
- Power Terminal: Connect the positive and negative poles of the DC24V switching power supply to the DC24V and 0V terminals.
- PLC Programming Port: Two ports (MiniB USB or Type-C/RS232) for downloading PLC programs.
- Touch Screen Programming Port: For downloading touch screen configuration programs.
- USB Interface: For direct insertion of a USB flash drive (FAT32 file system).
- SD Card: For storing historical records.
- Network Port: Supports program downloading or Modbus TCP/IP protocol (PLC and HMI network ports cannot coexist).
- Wireless Network Card: Supports optional WiFi or 4G, occupies the USB download port of the touch screen.
3.2 Software Installation
The touch screen software, CoolMayHMI, is compatible with Windows XP/7/8/10. If installation issues occur, consider replacing the computer, reinstalling the system, or trying higher user permissions.
- Install CoolMayHMI: Double-click the Vcool executable file (e.g.,
Vcool *.**.exe) and follow the prompts. A device driver installation wizard will appear. - Driver Installation: Click "Next" in the driver installation wizard to install the USB driver. If you click "Cancel", the USB driver will not be installed.
- Verify Installation: After successful driver installation, a prompt will confirm the installation.
3.3 Creating a New Touch Screen Program
- Launch Software: Double-click the Vcool software icon to create a new file.
- Project Settings: In the project creation dialog, enter a project name, select the appropriate model (e.g., EX3U-8070H), and choose the display mode (e.g., Horizontal).
- Communication Protocol: Configure the communication protocol by adding a "Device Manufacturer" and "Name", then set the required communication parameters. Click "OK" to proceed to screen program editing.
3.4 Downloading Configuration to HMI
After creating and saving your program, you can download it to the HMI:
- Compile: In the software, go to
Tools>Compile. - Download Method: After successful compilation, click the "Download" icon or go to
Tools>Download. A dialog box will appear with options: - USB Download: Connect the HMI to the computer via USB. Ensure the touch screen driver is correctly installed.
- Serial Port Download: Connect the HMI to the computer via RS232 or RS485. Set the corresponding COM port.
- Ethernet Download: Connect the HMI to the network and specify the IP address and port.
- Download Options: You can choose to clear recipe data, event records, or data sampling records before downloading. You can also update lower-level programs or synchronize HMI time with the computer.
- Start Download: Click "Download". The progress will be displayed on both the computer and the HMI.
3.5 Uploading Configuration from HMI
To upload the configuration project, event data, etc., from the HMI to the computer:
- Access Upload: Click the "Upload" icon on the toolbar.
- Select Content: Choose whether to upload project files, data sampling, or event records.
- Connection Method: Select USB, serial, or Ethernet transmission.
- Start Upload: Click "Upload". The corresponding file (e.g., .prj for project, .tar.bz2 for data/events) will be generated.
3.6 USB Flash Drive Download
You can also update the HMI via a USB flash drive:
- Export Project: Go to
Tools>Export Project to USB Disk. - Select USB Path: Choose the desired USB disk path.
- Compile and Export: Click "Export" to compile the current project. The generated
.binfile will be copied to the selected USB disk. - Update HMI: Insert the USB disk into the HMI. Use the "Project Update" section in the "Touch Screen Parameter Settings" on the HMI to update the configuration project.
4. Wiring Diagrams
Proper wiring is crucial for the safe and correct operation of the Coolmay EX3U-8070H-44MRT. Always ensure the device is powered off before making any connections.
4.1 General Wiring Setup

Figure 3: Example wiring setup for the Coolmay EX3U-8070H-44MRT, showing connections for USB-232 serial port cable, 232 programming cable, AC 220V, power supply (DC24), Type-C HMI programming cable, and Type-C PLC programming cable.
4.2 Detailed Wiring Diagram
The following diagram illustrates the input, output, pulse, and analog wiring for the PLC. Refer to this diagram for precise connections.

Figure 4: Detailed wiring diagram including input wiring (Diagram 10), relay output equivalent circuit (Diagram 11), transistor output equivalent circuit (Diagram 12), inductive load absorption circuit schematic (Diagram 13), pulse output wiring diagram (Diagram 14), and PLC analog wiring (Diagram 15).
4.3 Handwheel Wiring
For handwheel pulse function, connect the handwheel to the PLC as follows:
- Handwheel 24V to PLC 24V.
- Handwheel 0V to PLC 0V.
- Handwheel A/B phase outputs to PLC X0/X1 inputs.
- PLC Y10/Y1 outputs to servo drive direction/pulse inputs.
- PLC COM to servo drive COM.
This setup allows the handwheel to control motor rotation, with each handwheel pulse corresponding to a specific number of motor pulses.
5. Operation
The Coolmay EX3U-8070H-44MRT features an intuitive HMI touch panel for operation and monitoring. The PLC functions are programmed using dedicated software.
5.1 HMI Interface Navigation
The HMI provides various screens for monitoring, parameter setting, and control. Navigation is typically done by touching the corresponding buttons or input fields on the screen.
- Operation Page: Displays real-time data, status, and control buttons for various machine actions (e.g., start, stop, move up/down).
- Parameter Setting Page: Allows adjustment of operational parameters such as cycle time, action time, and delay.
- Timing/Counting Page: Configures and monitors timing and counting functions.
- I/O Detection Page: Displays the status of input (X) and output (Y) points for diagnostic purposes.
- Mold Data Page: Manages and stores different mold configurations.
- History List Page: Accesses historical data and alarms.
- System Settings Page: Configures system-level parameters like language, LCD backlight time, and communication intervals.
5.2 Analog Input/Output
The device supports analog inputs and outputs. Analog input values can be directly read from corresponding registers. Analog output values can be set within a range of 0-4000, with 12-bit accuracy.
- Analog Input Types: Supports voltage (0-10V) and current (0-20mA, 4-20mA) inputs.
- Analog Output Types: Supports 0-10V or 0-20mA analog signals.
- Sampling: The number of sampling cycles (D1377) and filter cycles (D1118) can be configured for analog inputs.
5.3 Weighing Function
The EX3U-8070H/HD can be equipped with 2 or 4 high-precision 24-bit AD weighing functions. This includes support for filtering, setting filtering times, and fault detection. Weighing values are stored in specific registers (e.g., R23700-R23707).
5.4 PID Control
The PID instruction is used for proportional, integral, and differential control. It adjusts output values based on input changes and is commonly used in mechanical, pneumatic, and electronic equipment. Parameters such as sampling time, proportional gain, integral gain, differential gain, and control mode can be configured.
5.5 High-Speed Counter and Pulse Output
The device supports both hardware and software high-speed counters. High-speed pulse outputs are used for positioning control, such as driving stepper motors.
- High-Speed Counting: Conventional counting supports single-phase 6-channel 200KHz or AB(Z) phase 2-channel 30KHz + AB phase 1-channel 5KHz.
- Pulse Output: Conventional 10 channels, 200KHz pulse output (Y0-Y11). Supports variable speed and acceleration/deceleration.
5.6 G Code and CNC Functions
The HMI can be used with G code and CNC functions for controlling equipment. G code files can be imported from a USB drive to the HMI and then downloaded to the PLC for execution. The system supports 4-axis G code (linked interpolation supports 8 axes) with high-precision interpolation algorithms.
6. Programming
The Coolmay EX3U-8070H-44MRT is programmed using the Coolmay VTool PRO software for the PLC and CoolMayHMI software for the HMI. It is compatible with GX Developer 8.86Q and GX Works2.
6.1 PLC Programming Notes
The PLC is compatible with VTool PRO programming software. When setting up a new program, you can specify the program title, PLC model settings, program capacity, and file name in the Model Settings window.
Programming can be done in two main modes:
- Ladder Diagram Mode: Programs are created using ladder logic. These must be compiled and converted into instruction code or SFC diagram.
- Instruction Mode: Programs are written using instruction lists. These must also be compiled and converted into ladder diagram or SFC diagram.
- SFC Programming Mode: Programs are created using Sequential Function Chart. These must be converted to instruction code through compilation.
6.2 Communication Port Instructions (MODBUS)
The PLC supports MODBUS communication protocols (RTU/ASCII) for master and slave configurations. Key instructions include MODRD (Modbus data reading), MODWR (Modbus data writing), and MODRW (Modbus data read and write).
- MODRD: Reads data from a slave device. S1 specifies the station number, S2 the target address, and 'n' the number of registers to read.
- MODWR: Writes data to a slave device. S1 specifies the station number, S2 the target address, and 'n' the number of registers to write.
- ADPRW: An advanced instruction for various MODBUS RTU functions like reading multiple bit/word devices, writing single bit/word devices, etc.
6.3 Interrupts
The PLC supports various types of interrupts to handle real-time events:
- External Interrupts: Triggered by input terminals (X0-X7) on rising or falling edges. These immediately interrupt the current program and jump to a specified interrupt insertion subroutine.
- Timer Interrupts: Triggered by configurable timers (I602-I699, I702-I799, I805-I899). The timing is not affected by the scan cycle time.
- Positioning Interrupts: Supports pulse output interrupt insertion for precise motion control.
- High-Speed Counter Interrupts: Triggered by high-speed counter events, allowing jumps to specific interrupt addresses.
Note that interrupts have priorities, with the last interrupt having the highest priority, which can terminate or pause previous executions.
Video 1: Demonstration of the Coolmay HMI PLC interface and functionality, showcasing various screens and settings.
7. Maintenance
To ensure the longevity and optimal performance of your Coolmay EX3U-8070H-44MRT, regular maintenance is recommended.
- Cleaning: Keep the HMI touch panel and the device's exterior clean. Use a soft, dry cloth. Avoid abrasive cleaners or solvents that could damage the screen or casing.
- Environmental Conditions: Ensure the device operates within its specified environmental conditions (temperature, humidity) to prevent damage.
- Firmware Updates: Periodically check the official Coolmay website for firmware updates. Keeping the firmware up-to-date can improve performance, add new features, and fix bugs.
- Cable Connections: Regularly inspect all wiring and cable connections for tightness and signs of wear or damage. Loose connections can lead to intermittent operation or faults.
- Backup Programs: Regularly back up your HMI and PLC programs to an external storage device (USB flash drive or computer) to prevent data loss.
- Power Supply: Ensure a stable DC24V power supply is used. Fluctuations or incorrect voltage can damage the unit.
8. Troubleshooting
This section provides solutions to common issues you might encounter with your Coolmay EX3U-8070H-44MRT.
8.1 General Issues
- Software Installation Issues: If CoolMayHMI software fails to install or run, try replacing the computer, reinstalling the operating system, or running the installer with higher user permissions.
- Communication Errors: Ensure all communication cables (USB, RS232, RS485, Ethernet) are securely connected and the correct communication parameters (baud rate, data bits, parity, stop bits) are configured in both the HMI/PLC and the programming software.
- HMI Not Responding: Check the power supply and ensure the POWER indicator is on. If the HMI is frozen, try restarting the device.
8.2 Programming and Download Issues
- Download Failure: If a download fails, especially for configuration files, reopen the host computer software and reconfigure before attempting to download again.
- Incorrect Program Execution: Ensure that the ladder diagram or instruction list is correctly compiled. For SFC programming, ensure it's converted to instruction code.
- G Code File Not Recognized: When importing G code files from a USB drive, ensure the file is placed in the root directory of the USB drive. The HMI only supports USB flash drives with a transmission rate of 2.0.
- USB Drive/HMI USB Interface Conflict: The USB disk and HMI USB interface cannot be used simultaneously. Ensure only one is connected at a time.
8.3 Advanced Function Issues
- PID Control Instability: Ensure the measured value (PV) is stable before PID calculations. If parameters are outside the specified range, the system will use default limits.
- Handwheel Abnormalities: If the handwheel behaves unexpectedly, ensure the gear ratio numerator and denominator are correctly set. If changing axes, clear the C232 value to prevent safety risks. Always turn off M1743 before replacing the axis.
- Chasing/Flying Shear Curve Issues: If the curve shape is abnormal (e.g., beginning and end unequal, straight line, weird shape), the curve data needs to be readjusted. Do not start M1632 cam curve calculation if it's not needed, as it can disorder the downloaded curve.
- MODBUS Data Storage Limits: If MODRD received data exceeds the storage range (D1070-D1085, D1296-D1312), data will be lost. For large data, use MODRW. MODWR can only write 1 word at a time; use MODRW for more.
- Ethernet Timeout: If no data is received within 30 seconds, the Ethernet port will close. Reconnect or enable the function via M1737.
9. User Tips
Based on user feedback, here are some tips to enhance your experience with the Coolmay EX3U-8070H-44MRT:
- Leverage Support: Users have praised the good service and product quality. Don't hesitate to contact Coolmay's sales team or technical support for assistance with software, programming, or any issues you encounter.
- Timely Delivery: Products are typically received fast, indicating efficient logistics. Plan your projects accordingly.
- Software and Manuals: Always ensure you have the latest software and manuals. They are available on the official Coolmay website.
- Pre-shipment Testing: All products are powered on and aged for more than 24 hours before shipment and tested to ensure quality.
10. Additional Resources
For more detailed information, programming guides, and specific model instructions, please refer to the official documentation:
- User Manual (PDF): A comprehensive user manual in PDF format is available for download. This document provides in-depth details on all aspects of the device. You can find it at: Coolmay EX3U-80 Series HMI/PLC All-in-one Programming Manual (PDF)
- Coolmay EX3U-80 All-in-One User Manual: Refer to this manual for general usage and hardware information.
- Coolmay EX3U-80 All-in-One Programming Manual: This manual provides detailed programming instructions.
- Coolmay TK80 Series Touch Screen User Manual: For specific usage of other touch screen software.
- Coolmay L01 Series PLC Programming Manual: For more practical applications of chasing shear and flying shear.
Please check the official Coolmay website for the latest versions of software and manuals.
11. Warranty and Support
Coolmay provides technical support and service for its products. For any inquiries regarding warranty, repairs, or technical assistance, please contact Coolmay PLC Official Store directly. Refer to the official website or your purchase documentation for specific warranty terms and conditions.
Coolmay offers unlimited services via email and video support. HMI and PLC software are provided free of charge.