1. Product Overview
The EARU AFDD-A-63 is an intelligent Arc Fault Detection Device (AFDD) that integrates the functionalities of a Miniature Circuit Breaker (MCB) and a Residual Current Circuit Breaker (RCCB). It is designed to detect and identify both fault arcs and normal working arcs within electrical lines, preventing fire hazards caused by issues such as poor contact or insulation. This device offers comprehensive protection, including arc fault protection, overload protection, short circuit protection, and leakage protection.

Key Features:
- Arc Protection
- Overload Protection
- Leakage Protection
- Short Circuit Protection
- Voltage Protection
- Lightning Protection
2. Specifications
| Parameter | Value |
|---|---|
| Pole Number | 2P |
| Rated Voltage | 230V |
| Frequency | 50/60Hz |
| Rated Residual Operating Current | 30 mA |
| Segmentation Capacity | 6kA |
| Tripping Characteristics | Type C (universal) |
| Available Current Ratings | 6A, 10A, 16A, 20A, 25A, 32A, 40A (Customizable) |
| Protection Functions | Arc / Short Circuit / Overload / Leakage Protection |
| Mounting | Din Rail |
| Certification | CE |
| Weight | 0.4 kg |

3. Installation and Setup
Safety First: All electrical work should be performed by a qualified electrician. Ensure the main power supply is disconnected before installation to prevent electric shock.
Mounting:
The AFDD-A-63 is designed for Din Rail mounting. Align the device with the Din Rail and press firmly until it clicks into place.

Wiring Schematic Diagram:
Connect the electrical wires to the designated wiring terminals as shown in the diagram. Ensure all connections are secure and tighten the screws appropriately. The device is a 2-pole unit, typically used for single-phase installations (Line and Neutral).


4. Operating Instructions
Powering On/Off:
- To close the circuit (power on), push the D Handle (red switch) upwards. The Visualization Window will show a red indication, and the Operating Indicator Light (green) will illuminate, indicating the circuit is operating normally.
- To open the circuit (power off), push the D Handle (red switch) downwards. The Visualization Window will show a green indication, and the Operating Indicator Light will turn off, indicating the circuit has stopped running.

Testing the Device:
Regularly test the AFDD to ensure proper functionality. Press the yellow 'Testing' button (Test Button) on the device. This should trip the circuit breaker, cutting off power. The Fault Indicator Light will illuminate, and the D Handle will move to the 'off' position. To restore power, reset the device by pushing the D Handle upwards.
Video Demonstration:
A demonstration of the AFDD-A-63's operation, including testing and resetting the device.
5. Maintenance
- Regular Testing: Perform the test procedure (Section 4) monthly to ensure the arc fault detection and other protection mechanisms are functioning correctly.
- Visual Inspection: Periodically inspect the device for any signs of physical damage, discoloration, or loose connections. Ensure the wiring terminals are tight.
- Cleaning: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or abrasive cleaners.
6. Troubleshooting
Device Trips Frequently:
- Arc Fault: If the Fault Indicator Light is on after tripping, it indicates an arc fault. Check for loose connections, damaged insulation, or faulty appliances in the circuit.
- Overload: If the current exceeds the rated current by approximately 10-20%, the breaker will trip. Reduce the load on the circuit.
- Leakage/Overvoltage: If an electrical leakage occurs and reaches 30mA, the device will trip. Inspect for ground faults or damaged wiring.
- Short Circuit: In the event of a short circuit, the device will immediately cut off power. Identify and rectify the short circuit.
After addressing the potential cause, reset the device by pushing the D Handle upwards. If the device continues to trip, consult a qualified electrician.

7. User Tips
- Current Rating Customization: The product is available in various current ratings (6A to 40A). If your specific current requirement is not listed, contact the seller for customization options.
- Two-Phase Compatibility: This 2-pole device is suitable for handling two conductors, making it compatible with typical single-phase (Line-Neutral) systems and potentially two-phase (Line-Line) systems depending on your regional electrical standards and voltage. Always verify with a qualified electrician for specific applications.
- Differential Type: While this device integrates MCB and RCCB functions, it is primarily an AFDD. For specific differential types (Type A, B, AC, F), consult the product's detailed technical documentation or a qualified electrician to ensure it meets your local regulations.
8. Warranty and Support
For warranty information, technical support, or any product-related inquiries, please contact the EARU Electric Store directly through your purchase platform. Ensure you have your purchase details and product model number (AFDD-A-63) ready for faster assistance.