JUNCTEK DPA-1698/DPA-2698

Contents

JUNTEK DPA-1698/DPA-2698 Dual-Channel Signal Power Amplifier

Instruction Manual

1. Introduction

The JUNTEK DPA-1698/DPA-2698 is a high-power, dual-channel signal generator and DDS power amplifier. It is designed to amplify the voltage amplitude of input signals by 2 times, providing a maximum current of 0.5A per channel and operating within a frequency range of 0-10MHz. The device features a robust, high-strength aluminum alloy shell for durability and efficient heat dissipation.

This amplifier is versatile, compatible with various signal generators, and can function as a standalone power amplifier with signal sources from other manufacturers. Its applications span across teaching equipment, industrial control, product line testing, metal detection, medical physiotherapy, medical beauty, and ultrasonic device driving.

Video: Overview of the JUNTEK DPA-2698 Dual-Channel Signal Power Amplifier, highlighting its features and applications.

2. Setup

2.1. Package Contents

Upon receiving your DPA-1698/DPA-2698 unit, please verify that all components are present and undamaged. The standard package includes:

  • 1 x DPA-1698/DPA-2698 Dual-Channel Function Generator Amplifier
  • 1 x 12V 5A Power Adapter (EU or US Plug)
  • 2 x Q9-Q9 Cables
JUNTEK DPA-2698 amplifier with power adapter and two Q9-Q9 cables

Image: The DPA-2698 unit along with its standard accessories: a power adapter and two Q9-Q9 cables.

2.2. Physical Overview

Familiarize yourself with the device's layout and connections:

Front view of JUNTEK DPA-2698 showing DC12V input, IN1, IN2, OUT1, OUT2, and display with specifications

Image: Front view of the DPA-2698, indicating DC12V power input, IN1/IN2 signal inputs, OUT1/OUT2 signal outputs, and the display showing key specifications like 25Vpp 0.5A max, 6dB(2X) Gain, 0-10MHz BW, and 5W x2 OUTPUT.

Rear view of JUNTEK DPA-2698 showing power input and BNC connectors

Image: Rear view of the DPA-2698, highlighting the DC12V power input and the BNC connectors for inputs and outputs.

2.3. Dimensions

The compact design of the DPA-1698/DPA-2698 allows for easy integration into various setups.

Dimensions of the JUNTEK DPA-2698 unit: 139mm (5.47in) length, 80mm (3.15in) width, 37.5mm (1.48in) height

Image: Dimensional drawing of the DPA-2698, showing its length as 139mm (5.47in), width as 80mm (3.15in), and height as 37.5mm (1.48in).

3. Operating Instructions

3.1. Initial Setup and Language Selection

Upon powering on the device for the first time, you will be presented with a welcome interface followed by a language selection screen. Use the soft keys to select your preferred language (English or Chinese). Subsequent power-ons will bypass this step and go directly to the main interface.

3.2. Main Interface and Waveform Output

The main interface allows for setting parameters and outputting waveforms. The device features a 2.4-inch TFT color LCD for display and various keys for control.

Key Functions:

  • Function Softkey: Activates the corresponding function displayed on the screen.
  • WAVE: Press to display the main interface or waveform selection menu.
  • MEAS: Fast switch between measurement mode interface and main interface.
  • MOD: Fast switch between modulation mode interface and main interface.
  • SYS: Fast switch between system setting interface and main interface.
  • OK: In the main interface, controls simultaneous output of CH1 and CH2 (ON/OFF). In other interfaces, confirms selection.
  • Left/Right Arrow Keys: Used to move the cursor position when setting parameters.
  • CH1 / CH2: Selects the respective channel for output control. Long press to set the channel as the main display.

Setting Parameters and Outputting Waveforms:

  1. Output Control: Press the OK button to toggle the output of both channels ON or OFF simultaneously.
  2. Channel Selection: Use the CH1 or CH2 keys to switch between channels. Pressing the key again will toggle the channel's output ON/OFF. Long press to display the selected channel on the main screen.
  3. Waveform Selection: Press the WAVE key to activate waveform switching. Rotate the knob to quickly switch waveforms. Use the direction keys to switch between arbitrary and preset waveforms. The amplifier supports Sine, Square, Pulse, Triangle, and Arbitrary waveforms.
  4. Frequency Setting: Press the FREQ soft key to highlight the "Frequency" parameter. Use the arrow keys to move the cursor and the knob to adjust the value. Long press FREQ to change the frequency unit (MHz, KHz, Hz, mHz, uHz).
  5. Duty Cycle, Offset, Phase: Long press the respective soft keys to reset these parameters to their default values.
Diagram showing various waveforms that can be amplified: Sine, Square, Pulse, Triangle, and Arbitrary waveforms, with a frequency range of 0-10MHz.

Image: Illustration of the arbitrary waveform amplification capability, showing Sine, Square, Pulse, Triangle, and Arbitrary waveforms within the 0-10MHz frequency range.

Diagram showing the amplified voltage range of 0-24Vpp with a fixed 2x amplification.

Image: Diagram illustrating the amplified voltage range of 0-24Vpp, achieved by a fixed 2x amplification of the input signal.

Diagram showing the maximum current output of 0.5A after single-channel waveform signal amplification.

Image: Diagram indicating that the maximum current output can reach 0.5A after single-channel waveform signal amplification.

Diagram showing dual-channel signal set for serial output with 180-degree phase difference, achieving 50Vpp and 1A current.

Image: Illustration of the dual-channel signal setup for serial output, demonstrating how adjusting the phase difference to 180 degrees can achieve a 50Vpp voltage and 1A maximum output current.

3.3. Measurement Mode

To enter the measurement mode, press the MEAS button. In this mode, you can measure various parameters of the input signal via the Ext.IN interface.

Measurement Function (Ext.IN):

  • Measurable Parameters: Frequency, period, positive pulse width, negative pulse width, duty cycle.
  • Frequency Range: 1Hz - 100MHz.
  • Signal Amplitude Range: 2Vpp - 20Vpp.
  • Coupling Setting: Press COUP to switch between AC or DC coupling.
  • Gate Time Setting: Press GATE to set the gate time (0.01S-10S). Use arrow keys and the knob to adjust.
  • Measurement Mode Switching: Press MODE to switch between counting frequency and counting period.

Counting Function:

The device can calculate the number of periods of the input signal in real-time.

  • Coupling Setting: Press COUP to switch between AC or DC coupling.
  • Start/Stop Counting: After setting parameters, press the soft key to start counting. Press the soft key again to stop.

3.4. Modulation Mode

Press the MOD button to enter the modulation mode. Use the FUNC key to switch between Sweep, Pulse, and Burst functions for CH1/CH2.

Sweep Function:

Allows setting a starting and ending frequency within the signal generator's output range, sweep time (0.1s-999.9s), and sweep type (linear or logarithmic). Sweep direction can be positive, reverse, or round trip.

  1. Press the soft key to select parameters like starting point frequency, end point frequency, sweep time, sweep direction, and sweep mode.
  2. Use arrow keys or the CHG key and knob to edit parameters.
  3. Press ON to start the sweep and OFF to stop.

Pulse Function:

Provides digital adjustment of pulse wave width and period, offering higher accuracy than duty cycle adjustment.

  1. Press the soft key to select pulse width, period, offset, and amplitude.
  2. Use arrow keys or the CHG key and knob to edit parameters.
  3. Press OK to switch pulse width and period units (ns/us).
  4. Press ON to start and OFF to stop.

Bursting Function:

The pulse train can be set to output 1-108575 periods. Burst modes include internal CH2 channel bursts, external input signal bursts, and manual bursts. Ensure the period time of the burst train is less than the burst signal period time.

  1. Press the soft key to select the number of pulses and the burst mode.
  2. Use arrow keys or the CHG key and knob to edit parameters.
  3. Press ON to start and OFF to stop.

3.5. System Settings

Press the SYS key to access system settings, including in/out position, sound, brightness, language, synchronization, and arbitrary wave display quantity.

  • Call Out & Save: Save or recall waveform parameters to/from specified memory locations (00-99). Rotate the knob to adjust the position. Use soft keys to recall, save, or clear.
  • Sound Settings: Toggle sounds ON/OFF using the ON / OFF keys.
  • Brightness Adjustment: Adjust display brightness from 0 to 12 levels by rotating the encoder.
  • Language Setting: Press ENG or 中文 to select English or Chinese.
  • Synchronization: CH1 acts as the master channel. CH2 parameters (frequency, waveform, amplitude, duty cycle, offset) will follow CH1. When highlighted, use arrow keys or the knob to select the item to synchronize. Press ON to select and OFF to cancel.
  • Arbitrary Waveform Number Setting: Quickly adjust the number of arbitrary waveforms (1-60) for the main interface by rotating the encoder.

4. Specifications

4.1. General Product Properties

  • Brand Name: JUNCTEK
  • Model Number: DPA-1698/DPA-2698
  • DIY Supplies: Electrical
  • Display Size: 2.9 Inches & Under
  • Battery Included: No
  • High-concerned chemical: None
  • Certification: CE
  • Origin: Mainland China

4.2. Detailed Technical Parameters

For a comprehensive understanding of the device's capabilities, please refer to the detailed specifications below. An official user manual in PDF format is also available for download: JUNTEK JDS6600 Series Operating Instruction (PDF)

Frequency Characteristics

ModelSine Wave Output Max Frequency
JDS6600-60M60MHz
JDS6600-50M50MHz
JDS6600-40M40MHz
JDS6600-30M30MHz
JDS6600-15M15MHz
CharacteristicJDS6600-15MJDS6600-30MJDS6600-40MJDS6600-50MJDS6600-60M
Sine wave frequency range0~15MHz0~30MHz0~40MHz0~50MHz0~60MHz
Square wave frequency range0~15MHz0-25MHz0-25MHz0-25MHz0-25MHz
Triangle wave frequency range0~6MHz0~6MHz0~6MHz0~6MHz0~6MHz
Pulse wave frequency range0~6MHz0~6MHz0~6MHz0~6MHz0~6MHz
TTL digital wave frequency range0~6MHz0~6MHz0~6MHz0~6MHz0~6MHz
Minimum frequency resolution0.01uHz (0.00000001Hz)
Frequency accuracy±20ppm
Frequency stability±1ppm/3hours

Waveform Characteristics

CharacteristicValue
Waveform typeSine, Square (adjustable duty cycle, precise adjustment of pulse width and period), Triangular, Partial Sine, CMOS, DC level (set DC amplitude by adjusting offset), Half Wave, Full Wave, Positive Staircase, Anti-ladder, Noise, Exponential Rise, Exponential Drop, Multisonic, Symplectic Pulse, Lorenz Pulse, and 60 arbitrary waveforms.
Wave length2048 points
Waveform sampling rate266MSa/s
Waveform vertical resolution14-bits
Sine wave Harmonic Suppression≥45dBc(<1MHz); ≥40dBc(1MHz~20MHz)
Total harmonic distortion<0.8%(20Hz~20kHz, 0dBm)
Square wave and pulse wave Overshoot≤5%
Pulse width adjustment range100nS~4000S (JDS6600-15M), 50nS~4000S (JDS6600-30M), 40nS~4000S (JDS6600-40M), 30nS~4000S (JDS6600-50M), 25nS~4000S (JDS6600-60M)
Square wave rise time≤25ns (JDS6600-15M), ≤15ns (JDS6600-30M), ≤10ns (JDS6600-40M/50M/60M)
Pulse wave Duty cycle adjustment range0.1%~99.9%
Partial sine wave Duty cycle adjustment range0.1%~99.9%
Sawtooth wave Linearity≥98%(0.01Hz~10kHz)

Output Characteristics

CharacteristicValue
Sine wave amplitude range (Frequency ≤ 10MHz)2mVpp~20Vpp
Sine wave amplitude range (10MHz < Frequency ≤ 30MHz)2mVpp~10Vpp
Sine wave amplitude range (Frequency > 30MHz)2mVpp~5Vpp
Square wave, Triangle wave amplitude range (Frequency ≤ 10MHz)2mVpp~20Vpp
Square wave, Triangle wave amplitude range (10MHz < Frequency ≤ 25MHz)2mVpp~5Vpp
Amplitude resolution1mV
Amplitude stability±0.5%/5 hours
Flatness of amplitude±5% (<10MHz); ±10% (>10MHz)
Output impedance50Ω±10% (typical)
ProtectionAll signal outputs can work within 60s when the load is short-circuited.

DC Offset

Output Amplitude RangeOffset Adjustment Range
> 2V-9.99V~9.99V
0.2V < Output Range ≤ 2V-2.5V~2.5V
0 < Output Amplitude ≤ 0.2V-0.25V~0.25V
Offset resolution0.01 V

Phase Characteristics

CharacteristicValue
Phase adjustment range0~359.9°
Phase resolution0.1°

TTL/CMOS Output

CharacteristicValue
Low level<0.3V
High level1V~10V

External Measurement Function

CharacteristicValue
Frequency meter range1Hz~100MHz
Measurement accuracyGate time 0.01S~10s continuous adjustment
Counting range0-4294967295
Coupling methodDC and AC coupling methods
Counting methodManually
Input signal voltage range2Vpp~20Vpp
Pulse width measurement0.01us resolution, maximum measurable 20s
Period measurement0.01us resolution, maximum measurable 20s

Sweep Function

CharacteristicValue
Sweep channelCH1 or CH2
Sweep typeLinear sweep, logarithmic sweep
Sweep time0.1s~999.9s
Setting rangeAny setting between the maximum output frequency of the corresponding model of the starting point (0.01Hz) and the end point
Sweep directionForward, reverse and round trip

Bursting Function

CharacteristicValue
Number of pulses1-1048575
Burst modeManual burst, CH2 burst, external burst (AC), external burst (DC)

General Specifications

CharacteristicValue
Display2.4 inch TFT color LCD display
Store and load Quantity100
Store and load Position00 to 99 (00 memory location parameter is loaded by default as power on)
Arbitrary wave Quantity1 to 60 total 60 groups (15 groups by default as power on)
Interface modeUSB to serial interface
Extension interfaceWith TTL level mode serial interface for user secondary development
Communication speedAdopt standard 115200bps
ProtocolUsing the command line, the protocol is made public
Power supply Voltage rangeDC5V±0.5V
Manufacturing technologySurface mount technology, large-scale integrated circuits, high reliability, long service life
Prompt toneUsers can turn on or off by setting program
Operating characteristicsAll key operations, knob continuous adjustment
Environmental conditionsTemperature: 0~40 °C Humidity: <80%

5. Maintenance

To ensure the longevity and optimal performance of your DPA-1698/DPA-2698, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the exterior of the device. Avoid using abrasive cleaners or solvents, which may damage the finish or internal components.
  • Storage: Store the device in a cool, dry environment, away from direct sunlight, extreme temperatures, and high humidity.
  • Handling: Handle the device with care to prevent physical damage. Avoid dropping or subjecting it to strong impacts.
  • Ventilation: Ensure that the ventilation slots on the device are not obstructed to allow for proper heat dissipation. The aluminum alloy shell is designed for efficient cooling.

6. Troubleshooting

If you encounter issues with your DPA-1698/DPA-2698, consider the following basic troubleshooting steps:

  • No Power: Ensure the power adapter is correctly connected to the device and a working power outlet. Verify the power adapter is supplying the correct DC12V.
  • No Signal Output: Check all cable connections (input and output). Ensure the correct channel is selected and its output is enabled (ON). Verify the input signal source is functioning correctly.
  • Incorrect Readings/Waveforms: Double-check all parameter settings (frequency, amplitude, offset, duty cycle). Ensure the correct waveform type is selected.
  • Device Overheating: Ensure the device is placed in a well-ventilated area and its heat sink fins are not covered.

If problems persist after attempting these steps, please contact customer support.

7. User Tips

  • Reliability: Users have noted the good quality of this device, indicating it is a reliable tool for its intended purpose.
  • Performance Expectation: While a capable and cost-effective solution, some users suggest managing expectations regarding its precision compared to higher-end, more expensive alternatives. It performs well for general applications but may not match the accuracy of premium instruments.

8. Warranty and Support

For any technical assistance, warranty claims, or support inquiries, please contact the manufacturer directly:

© 2024 JUNCTEK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.