jikong JK-LCD-4.3-TTL-P

Contents

JIKONG 4.3-inch Smart Touch Screen Display User Manual

Model: JK-LCD-4.3-TTL-P | Brand: JIKONG

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your JIKONG 4.3-inch Smart Touch Screen Display. This display is designed to work seamlessly with specific JIKONG V19 PB Series Battery Management Systems (BMS) to provide real-time monitoring and control of your battery pack.

2. Package Contents

  • 1 x JIKONG 4.3-inch Smart Touch Screen Display
  • 1 x Connection Cable

3. Specifications

FeatureDescription
Model NumberJK-LCD-4.3-TTL-P
Accessory TypeBattery Accessories
Display TypeTFT
Display Size4.3 inches
Resolution480*272
Power Supply Range9~36V (default)
Operating Temperature-20℃ to +70℃
Storage Temperature-30℃ to +80℃
Supported LanguagesChinese, English, Thai, Vietnamese
CertificationsCE, FCC, RoHS
Battery IncludedNo
Charger IncludedNo

4. Compatibility

This JIKONG 4.3-inch Smart Touch Screen Display is specifically designed for use with the following JIKONG V19 PB Series BMS models:

  • JK-PB1A16S10P-V19
  • JK-PB1A16S15P-V19
  • JK-PB2A16S15P-V19
  • JK-PB2A16S20P-V19
  • JK-PB2A16S30P-V19

Please ensure your BMS model is listed above for proper functionality.

5. Setup

5.1 Connecting the Display

  1. Ensure your JIKONG V19 PB Series BMS is powered off before making any connections.
  2. Locate the dedicated display port on your compatible JIKONG BMS.
  3. Connect one end of the provided connection cable to the display port on the BMS.
  4. Connect the other end of the cable to the port on the back of the 4.3-inch Smart Touch Screen Display. Ensure the connection is secure.
  5. Once connected, you may power on your BMS. The display should automatically initialize.
JIKONG 4.3-inch display connected to a compatible BMS board

Figure 5.1: JIKONG 4.3-inch display connected to a compatible BMS board, illustrating the physical connection.

Rear view of the JIKONG 4.3-inch display, showing the PCB and connection ports

Figure 5.2: Rear view of the JIKONG 4.3-inch display, showing the PCB and connection ports.

6. Operating Instructions

The JIKONG 4.3-inch Smart Touch Screen Display features a large, clear interface for convenient operation and monitoring of your battery system.

6.1 Main Display Interface

Upon startup, the display will show the main monitoring interface, providing a comprehensive overview of your battery's status. This includes:

  • Vtg (Voltage): Real-time total battery voltage.
  • Cur (Current): Real-time charge or discharge current.
  • Bat-Capacity (Ah): Total battery capacity in Ampere-hours.
  • Rem-Capacity (Ah): Remaining battery capacity in Ampere-hours.
  • Max.Cell: Highest voltage among individual cells.
  • Min.Cell: Lowest voltage among individual cells.
  • Temp: Battery pack temperature.
  • Pwr(kw): Real-time power in kilowatts.
  • Alarm: Indication of any active alarms.
  • CHG (Charge): Status of charging (ON/OFF).
  • DCH (Discharge): Status of discharging (ON/OFF).
Main display interface showing real-time battery parameters

Figure 6.1: Main display interface showing real-time battery voltage (Vtg), current (Cur), battery capacity (Bat-Capacity), remaining capacity (Rem-Capacity), maximum cell voltage (Max.Cell), minimum cell voltage (Min.Cell), temperature (Temp), power (Pwr(kw)), alarm status, charge (CHG) and discharge (DCH) status, and navigation options (GROUP, PACKS, SETTING).

6.2 Viewing Cell Pack Information

Navigate to the 'PACKS' section on the display to view detailed information for each individual cell within your battery pack. This screen provides a visual representation and specific voltage readings for each cell, allowing for precise monitoring of cell balance and health.

Display screen showing an overview of all cell pack information

Figure 6.2: Display screen showing an overview of all cell pack information, indicating individual cell status.

Display screen detailing individual cell pack information and communication settings

Figure 6.3: Display screen detailing individual cell pack information, including voltage, and options for setting up RS485 and CANBUS protocols.

6.3 Settings and Communication Protocols

The 'SETTING' menu allows you to configure various parameters and communication protocols. This includes the ability to set up RS485 and CANBUS protocols, which are essential for advanced communication with other devices in your system.

6.4 Language Selection

The display supports multiple languages: Chinese, English, Thai, and Vietnamese. You can change the language setting through the display's menu options to suit your preference.

7. Maintenance

To ensure the longevity and optimal performance of your JIKONG Smart Touch Screen Display, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry, anti-static cloth to clean the screen. Avoid using harsh chemicals, abrasive cleaners, or excessive moisture, which can damage the display surface.
  • Handling: Handle the display with care. Avoid dropping it or subjecting it to strong impacts.
  • Environmental Conditions: Operate and store the display within the specified temperature ranges (-20~+70℃ operating, -30~+80℃ storage) to prevent damage.
  • Connections: Periodically check the connection cable for any signs of wear or damage. Ensure it is securely plugged into both the display and the BMS.

8. Troubleshooting

If you encounter issues with your JIKONG Smart Touch Screen Display, refer to the following common troubleshooting steps:

  • Display Not Turning On:
    • Verify that the BMS is powered on.
    • Check the connection cable between the display and the BMS to ensure it is securely connected at both ends.
    • Confirm that the power supply to the BMS is within the display's operating range (9-36V).
  • Incorrect Readings:
    • Ensure the display is compatible with your specific JIKONG V19 PB Series BMS model.
    • Restart the BMS and the display.
    • If readings remain incorrect, consult your BMS manual for calibration or diagnostic procedures.
  • Unresponsive Touch Screen:
    • Gently clean the screen surface to remove any dirt or debris.
    • Restart the display by cycling power to the BMS.
    • Ensure the operating temperature is within the specified range.
  • Communication Errors (RS485/CANBUS):
    • Verify the settings in the 'SETTING' menu are correctly configured for your system.
    • Check the physical wiring for the RS485 or CANBUS connections.
    • Refer to the documentation for your connected devices and BMS for specific communication protocol requirements.

If problems persist after attempting these steps, please contact JIKONG customer support for further assistance.

9. User Tips

  • Regular Monitoring: Periodically check the 'PACKS' screen to monitor individual cell voltages. This helps in identifying potential cell imbalances early, which can prolong the life of your battery pack.
  • Firmware Updates: Keep an eye on the official JIKONG website or support channels for any available firmware updates for your display or BMS, as these can introduce new features or improve performance.
  • Environmental Protection: While the display has a wide operating temperature range, protecting it from direct sunlight or extreme cold when not in use can help maintain its performance and lifespan.

10. Warranty and Support

JIKONG products are manufactured to high-quality standards. For warranty information and technical support, please refer to the official JIKONG website or contact your authorized dealer. Keep your purchase receipt as proof of purchase.

This product is certified with CE, FCC, and RoHS standards, ensuring compliance with relevant safety and environmental regulations.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.