EASUN POWER ISolar-SMG-III-6.2KW-Wifi

EASUN POWER ISolar-SMG-III-6.2KW-Wifi Hybrid Solar Inverter

User Manual

Introduction

This manual provides essential information for the installation, operation, and maintenance of the EASUN POWER ISolar-SMG-III-6.2KW-Wifi Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper and safe use of the inverter.

EASUN POWER Hybrid Solar Inverter 6.2KW 48V with WiFi module

Figure 1: EASUN POWER ISolar-SMG-III-6.2KW-Wifi Hybrid Solar Inverter with WiFi module. Highlights key specifications like 6.2KW rated power, 48V battery voltage, 120A charge current, max 6500W PV array power, 500VDC max PV array voltage, and 96% peak efficiency.

Product Overview

The EASUN POWER ISolar-SMG-III-6.2KW-Wifi is a multi-functional inverter/charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display provides user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Front Panel and Indicators

Inverter front panel with LCD display, function keys, and LED indicators

Figure 2: Front panel of the inverter showing the LCD display, function keys, and LED indicators.

LED Indicators

LED IndicatorMessages
AC / INV (Green, Solid On)Output is powered by utility in Line mode.
AC / INV (Green, Flashing)Output is powered by battery or PV in battery mode.
CHG (Green, Solid On)Battery is fully charged.
CHG (Green, Flashing)Battery is charging.
FAULT (Red, Solid On)Fault occurs in the inverter.
FAULT (Red, Flashing)Warning condition occurs in the inverter.

Function Keys

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

Rear Panel Connections

Rear panel connections of the inverter with numbered labels

Figure 3: Rear panel of the inverter detailing connection ports.

  1. RS485 communication port
  2. RS232 communication port
  3. Power on/off switch
  4. Grounding
  5. AC input
  6. AC output
  7. PV input
  8. Battery input

Features

The EASUN POWER ISolar-SMG-III-6.2KW-Wifi Hybrid Solar Inverter offers a range of advanced features for efficient and reliable power management:

  • Lithium battery activation function by PV or Utility
  • Compatible work with LiFePO4 battery via RS485
  • Pure sine wave output
  • Power factor 1.0
  • PV input Voltage range: 60Vdc-500Vdc
  • Built-in MPPT solar charge controller (60A/100A/120A)
  • Capable to work without battery
  • Detachable dust cover for harsh environments
  • WiFi remote monitoring (optional)
  • Support multiple output priority settings: UTL (Utility), SOL (Solar), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery)
  • EQ function to optimize battery performance and extend lifecycle
Graphic summarizing key features of the inverter

Figure 4: Summary of key inverter features.

Specifications

Detailed technical specifications for the ISolar-SMG-III-6.2KW-Wifi model:

Detailed specifications table for the ISolar-SMG-III-6.2KW-Wifi model

Figure 5: Comprehensive technical specifications.

CategoryParameterValue
ModelModel NumberISolar-SMG-III-6.2KW-Wifi
Rated PowerRated Power6.2KVA/6.2KW
InputVoltage230Vac
Selectable Voltage Range(170Vac~280Vac)±2%;(90Vac-280Vac)±2%
Frequency Range50Hz/60Hz (Autodetection)
OutputAC Voltage Regulation (Batt. Mode)230VAC±5%
Surge Power12400VA
Transfer Time10ms (for personal computers) / 20ms (for home appliances)
WaveformPure Sine Wave
Battery & AC ChargerBattery Voltage48VDC
Floating Charge Voltage54VDC
Overcharge Protection63VDC
Maximum Charge Current80A
Solar ChargerMax. PV Array Power6500W
MPPT Range @ Operating Voltage60-500VDC
Maximum PV Array Open Circuit Voltage500VDC
Maximum Charging Current110A
PhysicalDimension (D*W*H)438 x 295 x 105 mm
Net Weight9.0 kg
Communication InterfaceRS232/RS485/WIFI
Operating EnvironmentHumidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C to 55°C
Storage Temperature-15°C to 60°C

Setup

Mounting the Unit

Mounting instructions and diagram for the inverter

Figure 6: Mounting instructions and dimensions.

  1. Do not mount the inverter on flammable construction materials.
  2. Mount on a solid surface.
  3. Install this inverter at eye level in order to allow the LCD display to be read at all times.
  4. The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  5. The recommended installation position is to be adhered to the wall vertically.
  6. Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

WARNING: Suitable for mounting on concrete or other non-combustible surface only.

PV Connection

PV connection diagram and parameters table

Figure 7: PV connection diagram and module selection parameters.

When selecting proper PV modules, please be sure to consider the following parameters:

  1. Open circuit Voltage (Voc) of PV modules should not exceed max. PV array open circuit voltage of inverter (500VDC).
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage (48VDC).

Inverter Model PV Parameters

ParameterValueNotes
Maximum PV output power6500W
Maximum PV open circuit voltage500VDC
Maximum charge current120A
Maximum Power (Pmax)250WMax. PV module numbers in series: 13 x 36V ≈ 60~500VDC
Max. Power Voltage Vmpp(V)36VPV module numbers in parallel: 13 x 8.3 < 120A
Max. Power Current Impp(A)8.3ATotal PV module numbers: 2 x 13 = 26
Open Circuit Voltage Voc(V)40V
Short Circuit Current Isc(A)8.9A

Battery Connection

48VDC Battery Connection Diagram

Figure 8: Diagram for connecting batteries in a 48VDC system.

The 6.2KW model supports a 48VDC battery system. Connect four 12V batteries in series to achieve the required 48VDC. Ensure correct polarity when connecting batteries.

Operating

System Diagram

System Diagram showing inverter operation with and without battery connected

Figure 9: Operational diagrams for the inverter, illustrating connections for solar power, generator, utility grid, battery packs, and home appliances, both with and without battery connection.

LCD Display Information

LCD display icons and their function descriptions

Figure 10: Detailed view of the LCD display and its various icons and their meanings.

IconFunction Description
ACIndicates the AC input.
PVIndicates the PV input.
INPUTBATTEMPIndicates input voltage, input frequency, PV voltage, battery voltage and charger current.
Configuration ProgramIndicates the setting programs.
Warning/Fault CodesIndicates the warning and fault codes. Warning: flashing with warning code. Fault: lighting with fault code.
OUTPUTBATTLOADIndicates output voltage, output frequency, load percent, load in VA, load in Watt and discharging current.
Battery InformationIndicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode and charging status in line mode.
Mode Operation: MainsIndicates unit connects to the mains.
Mode Operation: PV PanelIndicates unit connects to the PV panel.
Mode Operation: BYPASSIndicates load is supplied by utility power.
Mode Operation: Utility ChargerIndicates the utility charger circuit is working.
Mode Operation: DC/AC InverterIndicates the DC/AC inverter circuit is working.

Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. Please follow these guidelines:

  • Keep the inverter clean and free from dust and debris. Ensure ventilation openings are not blocked.
  • Periodically check all wiring connections for tightness and signs of corrosion.
  • Inspect the battery terminals for corrosion and clean if necessary.
  • Monitor the LCD display for any warning or fault codes and address them promptly.
  • Ensure the ambient temperature around the inverter remains within the specified operating range (-10°C to 55°C).
  • If the detachable dust cover is installed, ensure it is properly secured and clean.

Troubleshooting

If you encounter issues with your inverter, refer to the LED indicators and LCD display for fault codes or warning messages. Common issues can often be resolved by checking connections, ensuring proper ventilation, or verifying battery status. For persistent problems, consult a qualified technician.

  • No Power Output: Check AC input, battery connections, and PV input. Verify the power on/off switch is in the 'ON' position.
  • Warning/Fault Codes: Refer to the LCD display section for the meaning of specific codes and take appropriate action.
  • Battery Not Charging: Ensure PV panels are receiving sufficient sunlight and are correctly connected. Check battery voltage and charger settings.
  • Overload Warning: Reduce the connected load to prevent damage to the inverter.

Warranty & Support

For warranty information and technical support, please contact your authorized dealer or the manufacturer directly. Keep your purchase receipt and product serial number handy for any inquiries.

© 2024 EASUN POWER. All rights reserved.


Related Documents - ISolar-SMG-III-6.2KW-WIFI

Preview EASUN POWER Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for EASUN POWER Hybrid Solar Inverter/Charger models, covering installation, operation, specifications, troubleshooting, and lithium battery setup.
Preview EASUN POWER Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for the EASUN POWER Hybrid Solar Inverter/Charger, detailing installation, operation, battery management (including lithium), specifications, and troubleshooting for models like ISolar-SMG-II.
Preview Easun Power ISolar SMG II 6.2KP Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for the Easun Power ISolar SMG II 6.2KP (6.2KVA 230Vac) hybrid solar inverter/charger, covering installation, operation, specifications, and troubleshooting for reliable power solutions.
Preview EASUN POWER Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for the EASUN POWER Hybrid Solar Inverter/Charger, covering installation, operation, specifications, and troubleshooting for models like 1.5KVA, 4KVA, 5.5KVA, and 6.2KVA.
Preview Hybrid Inverter User Manual: 3.6KW, 4.2KW, 6.2KW
Comprehensive user manual for the Easun Power Hybrid Inverter models 3.6KW, 4.2KW, and 6.2KW, covering installation, operation, specifications, and troubleshooting.
Preview EASUN POWER Hybrid Solar Inverter/Charger 8.5KVA/11.0KVA User Manual
Detailed user manual for EASUN POWER Hybrid Solar Inverter/Charger models 8.5KVA and 11.0KVA (230Vac). This guide covers installation, operation, safety protocols, key features, technical specifications, and troubleshooting for efficient solar energy management.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.