1. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly polarized and securely connected.
- Do not attempt to repair the inverter yourself. Contact qualified service personnel.
- Keep the inverter away from flammable materials and ensure adequate ventilation.
- Disconnect all power sources (PV, AC, Battery) before performing any maintenance or wiring.
- This inverter is designed for indoor use. Avoid exposure to rain, snow, or excessive dust.
2. Product Overview and Key Features
The ANERN EVO-10200 is a pure sine wave hybrid solar inverter designed for both self-consumption and grid-tie applications. It integrates a solar charge controller, inverter, and battery charger functions to offer uninterruptible power support.
Key Features:
- Pure sine wave solar inverter output.
- Supports self-consumption and feed-in to the grid.
- Capable of running without a battery.
- One-key restoration to factory settings.
- Built-in automatic activation for lithium batteries.
- Integrated 160A MPPT solar controller (for 8.2KW and 10.2KW models).
- Wide PV input voltage range (90-450VDC).
- Built-in anti-dusk kit for harsh environments.
- Smart battery charge design to optimize battery life.
- Dual input & output for enhanced flexibility.
- Dual MPPT for the 10.2KW model.
- WIFI monitoring available for iOS and Android devices.


3. Setup and Installation
3.1 Unpacking and Inspection
Before installation, carefully unpack the inverter and inspect it for any damage. Ensure all components listed in the packing list are present.
3.2 Mounting the Inverter
- Choose a suitable location: The inverter should be mounted indoors, in a dry, well-ventilated area, away from direct sunlight and heat sources.
- Ensure sufficient clearance around the inverter for proper heat dissipation (at least 20 cm on all sides).
- Mount the inverter vertically on a sturdy wall using appropriate screws and anchors.
3.3 Wiring Connections
All wiring should comply with local electrical codes and standards. Use appropriate wire gauges for all connections.
- PV Input Connection: Connect the solar panel strings to the PV input terminals. Ensure correct polarity (+/-) and that the PV voltage is within the inverter's specified range (90-450VDC). The 10.2KW model features dual PV inputs.
- Battery Connection: Connect the battery bank (48VDC) to the battery terminals. Observe correct polarity. The inverter supports automatic activation for lithium batteries.
- AC Input Connection: Connect the utility grid (AC input) to the designated terminals.
- AC Output Connection: Connect your home appliances/load to the AC output terminals. The inverter provides dual AC outputs.
- Grounding: Ensure the inverter is properly grounded according to local regulations.


3.4 Initial Power-Up
Once all connections are secure and verified:
- Turn on the battery breaker (if applicable).
- Turn on the PV array DC disconnect switch.
- Turn on the AC input breaker.
- Turn on the inverter's power switch.
- Observe the display for status indicators and ensure normal operation.
4. Operating Instructions
4.1 Operating Modes
The inverter supports various operating modes, including Grid-tie with battery backup, Off-grid, and Grid-tie without battery. The specific mode can be configured via the inverter's display panel or monitoring software.
4.2 Wi-Fi Monitoring
The inverter features built-in Wi-Fi for remote monitoring via a dedicated mobile application (available for iOS and Android). This allows users to view real-time performance data, historical records, and adjust settings remotely.

4.3 One-Key Restoration
In case of misconfiguration or unexpected behavior, the inverter offers a one-key restoration feature to revert settings to factory defaults. Refer to the detailed instructions in the full manual for this procedure.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter system.
- Cleaning: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connection Checks: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
- Battery Health: Monitor battery voltage and charge cycles via the monitoring app. The smart battery charge design helps optimize battery life, but regular checks are recommended.
- Environmental Check: Ensure the installation environment remains dry, well-ventilated, and within the specified operating temperature range.
6. Troubleshooting
This section provides guidance for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not powering on | No battery power, battery switch off, loose connections, no AC input. | Check battery voltage, ensure battery switch is ON, verify all connections, check AC input breaker. |
| Low or no power output | Insufficient PV input, battery low, overload, inverter error. | Check PV array for shading/damage, check battery charge level, reduce load, check display for error codes. |
| Wi-Fi monitoring not working | No Wi-Fi signal, incorrect app settings, inverter Wi-Fi module issue. | Ensure inverter is within Wi-Fi range, reconfigure app settings, restart inverter. |
| Unusual noises or smells | Internal component failure, overheating. | Immediately disconnect all power sources and contact technical support. Do not operate. |
7. Specifications
The following table details the technical specifications for the EVO-10200 model, alongside other models in the series for comparison.

| Parameter | EX-Pro-7200 | EX-Pro-8200 | EX-Pro-10200 |
|---|---|---|---|
| Rated Power | 7200W | 8200W | 10200W |
| Maximum PV Input Power | 7500W | 8200W | 10200W |
| Maximum Solar Charging Current | 140A | 160A | 160A |
| GRID-TIE OPERATION (PV Input) | |||
| Nominal DC Voltage / Max DC Voltage | 360VDC / 500VDC | ||
| MPPT Voltage Range | 90V-450VDC | ||
| Grid Output (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Maximum Output Current | 31.3A | 35.6A | 44.3A |
| OFF-GRID OPERATION (AC Input) | |||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Maximum AC Input Current | 40A | 40A | 50A |
| Battery Mode Output | |||
| Nominal Output Voltage | 48VDC | ||
| Output Waveform | Pure sine wave | ||
| Efficiency (DC to AC) | 94% | ||
| PHYSICAL & COMMUNICATION | |||
| Communication Interface | WIFI | ||
| Dimensions (Diameter x Width x Height) | 500mm x 390mm x 130mm | 500mm x 390mm x 130mm | 530mm x 390mm x 130mm |
| Weight | 14.2Kg | 14.2Kg | 14.5Kg |
8. Warranty and Support
For warranty information, please refer to the official product documentation provided at the time of purchase. In case of technical issues or questions not covered in this manual, please contact the manufacturer's customer support or your authorized dealer.
Contact Email: A1boutiquestore@163.com
9. User Tips
- Model Selection: When choosing an inverter, carefully compare the specifications of different models (e.g., EVO-7200, EVO-8200, EVO-10200) to ensure it meets your power requirements and system design. Pay attention to rated power, maximum PV input, and solar charging current.
- Monitoring App: Utilize the Wi-Fi monitoring app to regularly check your system's performance, battery status, and energy production. This helps in proactive maintenance and optimization.
- Battery-less Operation: The inverter's ability to run without a battery can be useful for grid-tie systems where energy storage is not a primary concern, or as a backup mode.