1. Product Overview

This user manual provides essential information, operating instructions, and maintenance guidelines for the PowMr POW-LIO48100-16S and POW-LIO48200-16S low-voltage residential energy storage battery series. This series is a lithium battery system developed by PowMr, designed for compatibility with various inverter brands.

It is intended for professional technical personnel involved in installation, operation, and maintenance, as well as end-users seeking technical information. Always review this manual carefully before use and keep it accessible.

The POW-LIO48 series is a battery module for low-voltage lithium battery systems, primarily for residential energy storage. It features high-precision multi-cell voltage and temperature acquisition, passive balancing (up to 300mA), and external communication interfaces (CAN, RS485, dry contact) for parallel connection of up to 16 batteries. An embedded BMS system monitors over-temperature, over-voltage, and over-current to ensure safety.

Play video
Watch video online

Video: PowMr Powerwall LiFePO4 Battery Introduction and Features.

2. Safety Instructions

⚠ Please mind potential fire risk and strictly follow the instruction manual for charging and storage. For disposal, please check your local authority's website for more information and dispose of the lithium-ion battery safely in accordance with the applicable legal requirements.

2.1. Labeling Explanation

  • ⚠ DANGER: Signifies a low-level potential hazard. Failure to avoid may result in minor or moderate injury.
  • ⚡ HIGH VOLTAGE: Indicates high voltage inside the battery module. Touching may lead to electric shock.
  • ⏚ GROUND: This is the ground protection port (PE). It must be securely grounded.

2.2. General Precautions

  • Store this manual securely for future reference.
  • Strictly follow all instructions to avoid equipment damage, injuries, or property loss.
  • Do not intentionally tear or damage warning labels or the product nameplate.
  • Erect clear signage at switch locations and use warning tape near operating areas.
  • Only personnel with relevant professional qualifications, thoroughly familiar with the system and this manual, are allowed to operate this product.

2.3. Power-On Measurement & Measuring Instruments

  • After installation, high voltage is present. Use insulated gloves and have accompanying personnel present during power-on measurements.
  • Use measuring equipment with suitable ranges and ensure correct, standardized electrical connections to avoid hazards.

2.4. Maintenance and Inspection

  • Ensure the battery and inverter are off, and electrical connections are disconnected before maintenance.
  • Confirm the battery is completely de-energized with a multimeter.
  • Use insulating materials for parts near potentially live components.
  • Never perform maintenance on live equipment. At least two personnel must be present.

3. Main Components

The PowMr Powerwall battery system includes the following main components:

No.ItemQuantity
1Battery Unit1
2Red-Positive Power Line1
3Black-Negative Power Line1
4Communication Cable1
5Product User Manual1
6Certificate of Conformity1
7Expansion Bolts9
8Wall Mount Bracket (POW-LIO48100-16S or POW-LIO48200-16S)1
9Warranty Card1
PowMr Powerwall Function Description Diagram

Image: PowMr Powerwall Function Description.

No.DescriptionNo.Description
1Orange plate2LCD display
3Grey plate4Wall mounted bracket
5Handle6M6 Positive terminal (2pcs)
7M6 Negative terminal (2pcs)8OFF/ON
9SOC Display10RS485/CAN
11RS23212RS485/RS485
13Reset14ADS
15Dry contact

4. Operating Principle and Structure

The PowMr Powerwall battery connects in parallel to the DC output of an energy storage inverter. When mains power is normal, the inverter supplies power to loads and charges the battery. If utility and photovoltaic power are cut off, the battery provides uninterrupted power to the inverter. When power is restored, the battery charges while loads are powered.

PowMr Powerwall Connection Structure Diagram

Image: PowMr Powerwall Connection Structure Diagram.

5. Installation Guide

5.1. Tools Required

Electric drill, hammer, wrench, M8*60 expansion bolts, Phillips screwdriver, multimeter, insulated gloves, Ethernet cable, power cable.

5.2. Installation Preparation

  • Installation, operation, and maintenance must be performed by trained and qualified professionals.
  • Ensure the inverter connected to the battery is a qualified power system.
  • Ensure the power system and battery pack are off before installation.
  • All power cables must have insulation; do not expose power cords.
  • Ensure the battery and power system are reliably grounded.

5.3. Wall-Mounted Installation Steps

  1. Select a solid wall (thickness > 150mm). Leave ~200mm clearance around the battery for airflow.
  2. Secure wall bracket A to the battery using 8 dedicated screws.
  3. Mark hole positions on the wall based on wall-mount bracket B.
  4. Drill 6 holes (depth ≥80mm). Mount M8 expansion bolts in upper holes and screw on nuts.
  5. Fix the mounting bracket to the wall with expansion bolts.
  6. Raise the battery (keeping it vertical) slightly higher than the mounting bracket, then hang it on the bracket.
PowMr Powerwall Easy Installation

Image: PowMr Powerwall Easy Installation.

5.4. Electrical Connection

Single Unit Wiring:

  1. Connect positive and negative terminals of the battery to the inverter using power cables.
  2. Complete the battery's grounding connection using the ground wire.
  3. Connect the RS485A (or CAN) port of the battery to the inverter's RS485 (or CAN) communication port.
  4. If used as a single unit, set the ADS DIP switch to 1.

Parallel Wiring:

  1. If using multiple batteries, press the low-voltage switch (ON/OFF) on each. Use a multimeter to check for consistent voltage across all batteries. If consistent, turn off batteries before proceeding.
  2. Connect the positive terminal of the first battery to the inverter's positive terminal, and the negative terminal of the last battery to the inverter's negative terminal using power cables.
  3. Connect the RS485B communication interface of adjacent batteries with communication cables.
  4. Connect the ground wire from all batteries to a common grounding point.
  5. Use a standard Category 6 cable to connect the RS485A (or CAN) interface of the host battery to the inverter's RS485 (or CAN) interface.
PowMr Powerwall Supports up to 16 Units in Parallel

Image: PowMr Powerwall supports up to 16 units in parallel for expanded capacity.

6. LCD Screen Operation

6.1. Button Overview

  • MENU: Enter the settings menu.
  • ENTER: Enter the next-level menu.
  • UP/DOWN: Navigate through options.
  • ESC: Return to the previous menu.

6.2. Screen Navigation

The LCD screen displays real-time data and operating status. Key information includes:

  • Battery Pack Voltage: Current voltage of the entire pack.
  • Charge/Discharge Current: Real-time current flow.
  • Cell Temperature: Temperature of individual cell groups.
  • Cell Voltage: Voltage of each of the 16 individual cells.
  • SOC (State of Charge): Current charge level.
  • FCC (Full Charge Capacity): Total capacity when fully charged.
  • RM (Remaining Capacity): Available capacity.
  • CC (Charge Cycles): Number of charge/discharge cycles.
  • Battery Operating Status: IDLE, CHG (Charging), DCH (Discharging).
  • Protection Records: SCP (Short Circuit), O/UTP (Over/Under Temperature), OCP (Overcurrent), UVP (Undervoltage), OVP (Overvoltage).

6.3. Communication Interface Configuration

The battery supports RS485 and CAN communication. The default RS485 protocol is Pylontech RS485 (V3.5), and the default CAN protocol is Pylontech CAN. Compatibility with other inverters may require changing the protocol via RS232 using the upper computer software.

DIP switches are used to define the battery communication code and for parallel connection settings. Refer to the detailed diagrams in the full user manual for specific configurations.

7. Maintenance

  • Do not immerse the battery in water. Store in a cool, dry environment when not in use.
  • Do not expose to fire or external heat.
  • Do not invert positive and negative poles. Never connect directly to a power outlet or short-circuit.
  • Do not mix batteries from different manufacturers, types, or ages.
  • Do not use batteries showing signs of heating, swelling, deformation, or leakage.
  • Do not pierce with sharp objects, throw, step on, hit, or impact the battery.
  • Do not disassemble or dismantle the battery. Unauthorized disassembly voids warranty.
  • If signs of heating, swelling, or unusual odors are detected, stop use and return to factory.
  • For long-term storage, perform a charge-discharge cycle every three months (40%~60% charge).
  • Use the battery within specified temperature ranges.
  • Follow the specified power-up sequence for battery and inverter.
  • Ensure load power does not exceed maximum continuous discharge current.
  • If unused for over 3 months, manually charge periodically to prevent deep discharge.

8. Troubleshooting

Fault SymptomCause AnalysisSolution
No DC OutputBattery Voltage Too Low, Protection ActivatedStartup after Charging Activation
Short Power Supply TimeInsufficient Battery Capacity or Failure to Reach Full ChargeConfirm Maintenance or Replace Battery
Battery Cannot Reach Full ChargeDC Voltage Output from Power System Lower than Minimum Charging VoltageAdjust Device's DC Output Voltage to Suitable Charging Voltage for Battery
Unstable Battery Output Voltage with Significant FluctuationsInterference with Management System OperationRestart the System
Temperature Monitoring Too LowDamage to Temperature-Sensing Crystal HeadReplace the Collection Line with a Temperature-Sensing Crystal Head
Unable to ChargeSingle Cell Protection Activated upon Full Battery ChargeDischarge Protection Removal
MOS temperature abnormalMOS tube damagedReplace BMS
Discharge overcurrent protectionInverter power exceeds limitMatch the number of batteries according to the inverter power value

9. Technical Specifications

ParameterPOW-LIO48100-16SPOW-LIO48200-16S
System Voltage51.2V
Capacity100Ah200Ah
Nominal Energy5.12KWh10.24KWh
Constant Voltage Charging Voltage58.4V
Max. Discharge Cutoff Voltage43.2V
Recommended Discharge Cutoff Voltage48V
Max. Charging Current100A150A
Recommended Charging Current40A
Max. Discharge Current100A150A
Max. Parallel Connection of Batteries16
Communication InterfaceRS232/RS485/CAN/Dry Contact
Cycle Life≥6000 Times @80%DOD, 25°C
Operating TempCharging: 0~60°C; Discharging: -10°C~65°C
Nominal Operation Altitude< 2000m
Nominal Operation Humidity<90%RH
IP GradeIP21
Recommended Operation EnvironmentIndoor
Battery Dimensions (LxWxH)510x440x170mm670x450x207mm
Net Weight44kg87kg

10. User Tips

  • Inverter Compatibility: Users report successful operation with PowMr inverters (e.g., HVM10.2, 48V 10k hybrid) and Deye hybrid inverters, noting good compatibility and stable performance.
  • Delivery and Packaging: Battery delivery is often fast, and packaging is generally robust, though occasional damage during transit has been reported.
  • Initial Charge: Batteries typically arrive with approximately 50% charge.
  • Dimensions: Always verify the exact dimensions of the battery before purchase and installation, as they might be larger than anticipated.
  • Circuit Breaker: Some users have noted that the battery package does not include a thermal circuit breaker. Plan accordingly for your installation.

11. Warranty and Support

For warranty claims, technical support, or any inquiries, please contact PowMr directly using the information below:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
Tel/Fax: +86 755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?